• 제목/요약/키워드: installation/management

검색결과 1,158건 처리시간 0.032초

PQM 및 PQMS 성능검증을 위한 실증시험 (The field-test of Power Quality Meter and Power Management System in order to verify the performance)

  • 최선규;송일근;권태호;한재욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

빌딩 및 일반 대수용가용 통합관리 시스템에 대한 적용사례 소개 및 전력사용 데이터 활용연구 (A Study of Electric Power Usage Data Utilization and Application regarding Consumer Portal System for Building and Large Consumers)

  • 최중인
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.101-106
    • /
    • 2011
  • An utilization of electricity usage measured data by region and time through the consumer portal system for building and large consumer are suggested. Electricity usage data by region and time can't be measured by traditional approach. A measured data from smart meters which are installed various regions can be utilized to set up a management of electricity peak demand.

빛공해 방지를 위한 관리기준 및 조명환경관리구역 설정 방안에 관한 연구 (A Study on the Control Standards and an Environmental Lighting Zone-Setting method for Making Light Pollution Management)

  • 김기태;오민석;김회서
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.27-33
    • /
    • 2011
  • This study aims to suggest some problems, which occur when environmental lighting zone is set by use-zone only, by comparing and analyzing the artificial illumination luminance. In addition, this study aims to review the control standards of light pollution and to suggest a practical environmental lighting zone-setting method. I checked out the standards of average surface luminance and luminance contrast as for light pollution management. In addition, I did some research on evaluation of light pollution on surroundings based on investigation of use-environment as for lighting environment setting method.

일부하 곡선을 이용한 배전계통 구간부하 관리방법 (A Section Load Management Method using Daily Load Curve in Distribution Systems)

  • 임성일
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.47-52
    • /
    • 2012
  • DAS(Distribution Automation System) is equipped with several software applications such as service restoration, loss minimization, and protective relay coordination. The software applications of DAS are very sensitive to the amount of section load being carried by a particular section of distribution lines. Moreover, each software application requires a different parameter of the section load according to its purpose. Therefore, This paper proposes a new section load management method using real-time measurement data of the distribution lines. In order to provide accurate data to DAS applications, this method considers section loads in terms of the relationship of power versus time. In order to establish that the proposed method is feasible, a performance-testing simulator was developed, and case studies were conducted for a modified real distribution network.

협력설계를 통한 건설 프로세스 개선 방안 (A Study on the Improving Construction Processes through the Cooperative Design)

  • 나경철;김창덕
    • 한국건설관리학회논문집
    • /
    • 제2권4호
    • /
    • pp.144-156
    • /
    • 2001
  • 본 연구에서는 종래 건설 프로세스 상의 한계점을 분석한 후, 그 개선방안을 제시하였다. 본 연구에서 제시하는 개선방안은 설계도서의 철저한 사전검토를 통한 협력 업체의 공정계획 조기참여 방안이다. 이를 통해서 커뮤니케이션이 활성화되어 사전의견조정의 극대화를 확보할 수 있다. 본 연구에서는 데크플레이트 설치 프로세스와 덕트 설치 프로세스를 대상으로 사례연구를 수행하였다. 사례연구 결과, 협력업체의 조기투입과 설계도서 사전 검토를 통하여 체계적으로 건설 프로세스를 개선할 수 있었고, 구성원들의 사전의견조정을 통하여 건설생산 효율성을 제고할 수 있었다.

  • PDF

미생물 안전을 위한 승용차 실내 UVGI 살균기 설치에 관한 시뮬레이션 연구 (A Study on simulation analysis of UVGI air sterilizer installation in a car for microbiological safety)

  • 최상곤
    • 대한안전경영과학회지
    • /
    • 제16권3호
    • /
    • pp.279-287
    • /
    • 2014
  • The recent rise in SARS and bird flu infections around the world has raised the interest in studying the habits of air borne pathogens such as germs and viruses. In this study, simulations were carried out to predict the performance of UVGI air sterilizer at preventing airborne infections inside a car, based on the installation position and the removing effect of the UVGI air sterilizer. Simulation results showed that the UVGI air sterilizer was most effective when located at the rear side of the front seats. It was also showed that when the out-air mode and the UVGI air sterilizer were set to the highest capacity, the microbial safety levels were maintained in a car for 21 hours.

지능형 전력관리시스템의 구축사례 (The Construction-Case of Intelligent Power Management System)

  • 고강훈;김천식;김수용;박정우;고희석;이현우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.214-218
    • /
    • 2000
  • This paper is a study if control system with KEN that is not only superior-manufacture ability-hardware; that is to say, the hardware is HMI/SACD solution and it has been developed to sub-station and power management system, which is easy, fast and suitable for users to work with, but also compatible solution with domestic environment Futhermore, the hardware has been developed by completely domestic technology with knowledge from various actual experiences. In the long run, for uninterruptible power supply to train, building, and factory, real time tele-supervisory control to power facilities.

  • PDF

배터리관리시스템(BMS)을 이용한 배터리 잔존수명(SOH) 추정 알고리즘에 관한 연구 (A Study on the Algorithm of Battery SOH Estimation for Battery Management System(BMS))

  • 서철식;문종현;박재욱;김금수;김동희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.317-320
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) and State Of Health(SOH) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOH, through the experiments which using the charge and discharge tester and the field tests.

  • PDF

UPS용 배터리 최적화를 위한 배터리관리시스템에 관한 연구 (A Study on the Battery Management System for the optimum conditions of the battery in UPS)

  • 문종현;서철식;박재욱;김금수;김동희
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.321-324
    • /
    • 2008
  • This paper presents the battery management system(BMS) for the optimum conditions of the lead-Acid battery in UPS. The proposed system controls the over and under currents of battery for protecting and it was applied algorithm for optimum conditions to estimate the State Of Charge(SOC) in charge or discharge mode. It approved the performance and the algorithm for the estimation of SOC, through the experiments which using the charge and discharge tester and the field tests.

  • PDF

흡음 외장재 부착에 따른 교량 주변 음향 특성 해석 (Analysis on the Acoustical Characteristics for Arrounding of Bridge by Absortion Panel Attatchment)

  • 이유엽
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.391-396
    • /
    • 2014
  • For the purpose of finding out the acoustical characteristics of exterior materials in bridge, analytical studies are performed with boundary elements method by using the commercial program SYSNOISE. Before analysis, to figure out material property, it was conducted experiments of absorption coefficient for absorptive material. And prediction of pressure were conducted I GIRDER type (before & after installation of absorption panel ) and BOX GIRDER type (before & after installation of absorption panel) The results show that when the absorption panel is installed, environment around bridge can help reduce traffic noise. It was proved to be the effective noise reduction counter-plan for a traffic noise in the bridges.