• Title/Summary/Keyword: inductively coupled plasma-mass spectrometry

Search Result 237, Processing Time 0.029 seconds

Application of Spectrochemical Analysis in the Study of Archaeological Textiles (복식유물의 연구에 있어서 분광화학분석의 활용)

  • 안춘순
    • Journal of the Korean Society of Costume
    • /
    • v.49
    • /
    • pp.49-63
    • /
    • 1999
  • This research utilized the Energy Dispersive X-ray Spectroscopy(EDS) and the Inductively Coupled Plasma Mass Spectrometry in the analysis of chemical elements present among the textiles exhumed from Kupori Hwasung-kun Kyunggi-do. The two research objectives were: first to examine the elements present and their percent presence in Kupori samples: second to investigate whether the elements are part of mordant substances which could have been used when dyeing the KUpori textiles in the past. To meet such research purposes standard silk fabric was dyed with Sophorajaponica using alum and iron mordants. For alum mordant unpurified general alum and potassium aluminum sulfate(AlK(SO4)2). iron sulfate(FeSO4·7H2O) were used, From the results of EDS and ICP-Mass analysis the following conclusions were drawn. 1 According to the EDS analysis 9 elements Ca, S, Al, Si, K, Fe, P, Mg and Na were detected. 2. ICP-Mass result of the mordant chemicas showed high amount of A, Al and k present in alum mordants and S and Fe present in iron mordants. 3. Comparison of the ICP-Mass results of the mordant chemicals and those of the standard dyed samples suggested that the amount presence of Al and Fe is a strong indication of the usage of alum and iron mordants respecticely in an unknown dyed textile. 4, In the washed Kupori textiles Fe showed a relatively higher rate of presence in the samples Therefore it can be conjectured that those Kupori textiles were dyed with iron mordant based on the result of the above number 3. 5. It is probable that the other elements detected from the Kupori samples were incorporated into the textiles as part of the soil debris produced from the degradation of the dead within the coffin or the earth debris. They can also be part of the inorganic compounds inherent in the silk textiles themselves before dyed. 6. Among the elements it is likely that Ca which showed a high degree of presence among the unwashed samples was part of the inorganic compound inferent in the silk textiles.

  • PDF

Quantification of Arsenic Species in Some Seafood by HPLC-AFS (HPLC-AFS를 이용한 해산물 중 비소 화학종 분리정량)

  • Jeong, Seung-Woo;Lee, Chae-Hyeok;Lee, Jong-Wha;Jang, Bong-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.5
    • /
    • pp.496-503
    • /
    • 2021
  • Background: Considering the expenses of and difficulties in arsenic speciation by high performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS), alternative measurement methods should be useful, especially for large-scale research and projects. Objectives: A measurement method was developed for arsenic speciation using HPLC-atomic fluorescence spectrometry (HPLC-AFS) as an alternative to HPLC-ICP-MS. Methods: Total arsenic and toxic arsenic species in some seafoods were determined by atomic absorption spectrometry coupled with hydride vapor generation (AAS-HVG) and HPLC-AFS, respectively. Recovery rate of arsenic species in seafood was evaluated by ultra sonication, microwave and enzyme (pepsin) for the optimal extraction method. Results: Limits of detection of HPLC-AFS for As3+, dimethylarsinate (DMA), monomethylarsonate (MMA) and As5+ were 0.39, 0.53, 0.60 and 0.64 ㎍/L, respectively. The average accuracy ranged from 97.5 to 108.7%, and the coefficient of variation was in the range of 1.2~16.7%. As3+, DMA, MMA and As5+ were detected in kelp, the sum of toxic arsenic in kelp was 40.4 mg/kg. As3+, DMA, MMA and As5+ were not detected in shrimp and squid, but total arsenic (iAS and oAS) content in shrimp and squid analyzed by AAS-HVG were 18.1 and 24.7 mg/kg, respectively. Conclusions: HPLC-AFS was recommendable for the quantitative analysis method of arsenic species. As toxic arsenic species are detected in seaweeds, further researches are needed for the contribution degree of seafood in arsenic exposure.

A Study on the Migration of Heavy Metals from Polycarbonate Food Contact Materials Using an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) (식품용 폴리카보네이트 기구류 중 ICP-MS를 이용한 중금속 이행량 조사)

  • Park, Se-Jong;Park, So-Ra;Kim, MeeKyung;Choi, Jae Chun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.3
    • /
    • pp.107-112
    • /
    • 2018
  • The purpose of this study was to investigate the migration levels of lead (Pb), cadmium (Cd) and arsenic (As) from polycarbonate food contact materials into food simulant at different temperatures ($70^{\circ}C$ and $100^{\circ}C$). The method was validated by linearity of calibration curves, limit of detection (LOD), limit of quantification (LOQ), recovery, precision and uncertainty. All of 200 samples, including bottles, cups, containers, ladles, spoons and tongs were purchased from domestic markets and analyzed by inductively coupled plasma mass spectrometry (ICP-MS). Mean concentrations of positive samples were higher at $100^{\circ}C$ than $70^{\circ}C$ as showing a dependency of migration temperature. The migration concentrations ranged from not-detected (ND) to $4.67{\mu}g/L$, ND to $0.49{\mu}g/L$L and ND to $2.91{\mu}g/L$ for Pb, Cd and As, respectively, which were far below the migration limits of Korea standards and specifications for food utensils, containers and packages.

Determination of trace arsenic in seawater by flow injection-hydride generation inductively coupled plasma mass spectrometry (연속흐름주입-수소화물생성-유도결합플라스마 질량분석장치를 이용한 바닷물표준시료중의 극미량 비소분석방법의 확립)

  • Suh, Jung-Ki
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.316-325
    • /
    • 2008
  • An inductively coupled plasma mass spectrometry (ICP-MS) instrument equipped with flow injection-hydride generation system was used for the determination of trace arsenic in seawater sample. The accuracy in this method was verified by the analysis of certified reference materials (CRM) of seawater (CASS-4, NASS-5). The analytical results agreed with certified value within the range of uncertainty. The expanded uncertainties for CASS-4 and NASS-5 in this experiment were ranged from 6.2% to 6.8% obtained from repeated analyses of the CRMs (n=5). The detection limit of $As^+$ (m/z=74.9216) in this method was confirmed about 0.01 ug/kg. Linearity obtained from calibration curve of arsenic was excellent ($R^2=1$). The detection at $As^+$ (m/z=74.9216) and $AsO^+$ (m/z=90.9165) by using oxygen reaction gas in DRC mode was compared. Sensitivity at $AsO^+$ (m/z=90.9165) was decreased about 25-fold, but the analytical results are the same that at $As^+$ (m/z=74.9216).

Determination of boron in steel by HNO3-NH4HF2 digestion and ICP-MS (질산-이플루오린화암모늄 분해 및 ICP-MS에 의한 철강 중 붕소 정량에 관한 연구)

  • Choi, Won Myung;Eum, Chul Hun;Park, Ilyong
    • Analytical Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.352-356
    • /
    • 2014
  • Various studies have been done to improve the properties of the steel by adding boron to the steel. Some studies have reported on the analysis of the boron in steel by AAS (atomic absorption spectrometry), ICP-OES(inductively coupled plasma-optical emission spectrometry), ICP-MS (inductively coupled plasma/mass spectrometry). The volatile loss of boron of steel in sample digestion and the separation procedure for avoiding matrix effect by high concentration of iron are difficulties for determination of boron in steel. The method to determine boron in steel by ICP-MS was developed without volatilization of boron in sample digestion step with $HNO_3-NH_4HF_2$ digestion method, and the additional separation process for avoiding matrix effect. Complete decomposition of steel with $HNO_3-NH_4HF_2$ digestion method, and boron determination by ICP-MS in the matrix of high concentration of iron were possible. Quantitative recoveries of boron in certified standard steel by new method in this study were 103 to 111%, and the relative standard deviation is less than 5%. The method detection limit was $1.17{\mu}g/g$.

CHARACTERISITCS OF CHLORINE IND DUCTIVELY COUPLED PLASMAS AND THEIR SILICON ETCH PROPERTIES

  • Lee, Young-Jun;Kim, Hyeon-Soo;Yeom, Geun-Young;Oho, Kyung-Hee
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.6
    • /
    • pp.816-823
    • /
    • 1996
  • Chlorine containing high density plasmas are widely used to etch various materials in the microelectronic device fabrication. In this study, the characteristics of inductively coupled $Cl_2(O_2/N_2$) plasmas and their effects on the formation of silicon etching have been investigated using a Langmuir probe, quadrupole mass spectrometry(QMS), X-ray photoelectron spectroscopy(XPS), and Scanning Electron Microscopy(SEM). The addition of oxygen for chlorine plasmas reduced ion current densities and chlorine radical densities compared to the nitrogen addition by the recombination of oxygen with chlorine. Also, when silicon is etched in $Cl_2/O_2$ plasmas, etch products recombined with oxygen such as $SiCl_xO_y$ emerged. However, when nitrogen is added to chlorine, etch products recombined with nitrogen or Si-N bondings on the etched silicon surface were not found. All the silicon etch characteristics were dependent on the plasma conditions such as ion density, radical density, etc. As a result sub micron vertical silicon trench etch profiles could be effectively formed using optimized etch conditions for $Cl_2/O_2\; and \;Cl_2/N_2$ gas combinations.

  • PDF

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

Analysis of Trace Level and Correlation of Lead in the Plasma of Field Workers and General Public by ICP-MS (유도결합플라즈마 질량분석법에 의한 납 취급 근로자와 일반인의 혈장 중 납 분석 및 상관성 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Kim, Nam-Soo;Lee, Byung-Kook;Shin, Ho-Sang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 2013
  • Objectives: This study attempted to develop a method to measure ultra-trace lead concentrations in plasma using Inductively Coupled Plasma Mass Spectrometry(ICP-MS) and to test whether plasma lead can be used as a biomarker for the biological monitoring of exposure to lead. Methods: Lead concentrations in 160 plasma samples of field workers and 42 plasma samples from the control group were measured by ICP-MS. Blood zinc protophorphyrin(ZPP) concentrations and urinary ${\delta}$-aminolevulinic acid${\delta}-ALA$) were measured for correlation analysis with plasma lead. Results: The mean lead level in the plasma of the workers exposed to lead at work were 786.1 ng/L. Plasma lead levels were not correlated with blood ZPP or urinary ${\delta}-ALA$ concentrations. Otherwise, plasma lead levels showed a good correlation coefficient of 0.400 with blood lead levels, and their correlation coefficient had a better value of 0.552 for the non-smoking and drinking group. In the general population group which was not exposed to lead in the workplace and was considered the control group, the mean concentration of plasma lead was 123.1 ng/L. The plasma lead levels for the general population group showed a good correlation coefficient of 0.520 with blood ZPP and urinary ${\delta}-ALA$ concentrations.

The analysis of impurities in rare earth oxide for fluorescent substance by ICP-MS (ICP-MS에 의한 형광체용 $(Y,\;Eu)_2O_3$ 중 불순물 분석 연구)

  • Kim, Sang-Kyoung;Jang, Seung-Kyu
    • Analytical Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • A survey was made on detection limit, reproducibility, matrix effect, linear dynamic range and the memory effect of yttrium and europium in order to analyze rare earth elements which exist as impurities in the rare earth oxide which is raw materials of fluorescent substance. When analysing a certain amount of thulium quantitatively using inductively coupled plasma mass spectrometry, it was found that the analysis was interfered with $EuO^+$ which is one of polyatomic ions caused by plasma. As the intensity of thulium linearly proportional to the europium concentration, it was possible to the determine the actual concentration of thulium.

  • PDF

Study on mechanism for etching of $SrBi_{2}Ta_{2}O_{9}$ thin film in $SF_6$/Ar gas plasma ($SF_6$/Ar 가스 플라즈마에 의한 $SrBi_{2}Ta_{2}O_{9}$ 박막의 식각 메커니즘 연구)

  • Kim, Dong-Pyo;Seo, Jung-Woo;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.867-869
    • /
    • 1999
  • In this study, $SrBi_{2}Ta_{2}O_{9}$(SBT) thin films were etched as a function of $SF_6$/Ar gas mixing ratio in magnetically enhanced inductively coupled plasma(MEICP) system fer a fixed rf power, dc-bias voltage, and chamber pressure. The etch rate of SBT thin film was $1500{\AA}/min$ and the selectivities of photoresist (PR) and $SiO_2$ to SBT thin film were 0.48 and 0.62, respectively when the samples were etched at a rf power of 600W, a dc-bias voltage of -150V, a chamber pressure of 10 mTorr and a gas mixing ratio of $SF_6/(SF_6+A)$=0.1. In order to examine the chemical reactions on the etched surface, X-ray photoelectron spectroscopy(XPS) and secondary ion mass spectrometry(SIMS) were done.

  • PDF