• 제목/요약/키워드: hyperthermia

검색결과 308건 처리시간 0.03초

A K-Band Low-Power Miniaturized Hyperthermia System

  • Kim, Dong-Ki;Kim, Ki-Hyun;Oh, Jung-Min;Park, Young-Rak;Kwon, Young-Woo
    • Journal of electromagnetic engineering and science
    • /
    • 제9권4호
    • /
    • pp.188-193
    • /
    • 2009
  • A K-band low-power miniaturized planar-type hyperthermia system was developed to replace massive and expensive equipment. The system consists of a VCO with a buffer amplifier, a high-power amplifier module, a 20-dB-coupled line coupler, a chip circulator and two power detectors for signal generation, amplification and power monitoring. All these components have been implemented in planar form on two module blocks. The total size of the hyperthermia system was less than $10\times6.5\times3\;cm^3$. In order to verify the system performance, ablations were carried out on nude mice xenografted with human breast cancer. Ablation results show performance comparable to the massive components-based system. This work shows the feasibility of a low-cost miniaturized hyperthermia system for practical clinical applications.

극초단파와 초음파온열치료에 의한 각종암의 임상치료 (Clinical Applications of Microwave and Ultrasound in Hyperthermia: Preliminary Results)

  • 고경환;박영환;조철구;류성열
    • Radiation Oncology Journal
    • /
    • 제6권1호
    • /
    • pp.75-80
    • /
    • 1988
  • Twenty seven lesions of 25 patients with locally advanced malignant tumors were treated with combined hyperthermia introduced by microwave and ultrasound and radiotherapy. Most of all patients were failed with previous conventional therapeutic trial. Hyperthermia had been done immediately after radiotherapy, twice a week, $43^{\circ}C$ for one hour and radiotherapy had been done 5 fractions per week with fraction size of 2Gy upto 30 to 60Gy. Conclusions are as follows. 1. Total response rate (PR+PR) to thermoradiotherapy with microwave and ultrasound was $81\%$. 2. Tumor depth, minimum temperature of tumor center, number of heat fraction and radiation dose were statistically significant factors affecting response. 3. Hyperthermia with microwave and ultrasound can be used efficiently to control locally advanced malignant disease whether previously received near tolerance dose of radiotherapy or not.

  • PDF

온열요법을 결합한 산삼비만약침의 폐경기 복부비만 개선효과: 증례보고 (The Effects of Wild Ginseng Complex Pharmacopuncture Combined with Hyperthermia on Abdominal Obesity in Post-Menopause Women: Case Report)

  • 유정은
    • 한방비만학회지
    • /
    • 제16권2호
    • /
    • pp.133-137
    • /
    • 2016
  • 폐경기 복부비만 환자 2명에게 2주 이내에 총 5회의 온열요법을 결합한 산삼비만약침 치료를 시행한 결과, 복부둘레의 감소를 확인할 수 있었다.

The Applications of the Duplex Stainless Steel as Hyperthermia Materials

  • Kim, Young-Kon
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.7.1-7.1
    • /
    • 2009
  • The use of Duplex stainless steel as a thermo-implant categorizes into two clinical applications: hyperthermia and thermal ablation or destruction. The goal of hyperthermia is to destroy the heat-sensitive abnormal cells and minimize normal cell death maintaining heat between $42^{\circ}C$ and $46^{\circ}C$. Thermal ablation takes place when the local tissue temperature increases greater than $46^{\circ}C$. This elevated temperature denatures protein irreversibly resulting cellular death. The author introduced several thermo-implants such as thermo-rod, thermo-stent, thermo-coil and thermoacupuncture-needle. Those thermo-implants are made of duplex stainless steel which can produce regulated heat by itself within an induction magnetic field. Thermal ablation characteristics of the thermo-rod on tumor hyperthermia depend on configurations of the thermo-rods and the magnitude of the induction magnetic strength. The exothermic properties of the thermo-implants can be characterized using the calorimetric test and the heat affected zone(HAZ) analyses in vitro. Thermal radiation studies using thermo-coils and thermo-stents show the capability of the occlusion of animal blood vessels and inhibiting the proliferation of the abnormal smooth muscle cell growth and inflammatory cell reactions maintaining the heat between $42^{\circ}C$ and $46^{\circ}C$ minimizing a normal cell death in the study on external iliac artery of the New Zealand White (NZW) rabbit. Thermal stimulation study using thermo-acupuncture needles suggests the potential applications of the automated acupunctural therapies.

  • PDF

Cetyl Trimethyl Ammonium Bromide-coated Nickel Ferrite Nanoparticles for Magnetic Hyperthermia and T2 Contrast Agents in Magnetic Resonance Imaging

  • Lee, Da-Aemm;Bae, Hongsubm;Rhee, Ilsum
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1334-1339
    • /
    • 2018
  • Spherical nickel ferrite nanoparticles were synthesized using the thermal decomposition method and coated with cetyl trimethyl ammonium bromide (CTAB) after the synthesis. Transmission electron microscopy images showed that the average diameter of the particles was 9.40 nm. The status of the CTAB-coating on the surface of the particles was checked using Fourier-transform infrared spectroscopy. Their hysteresis curve showed that the particles exhibited a superparamagnetic behavior. The $T_1$ and the $T_2$ relaxations of the nuclear spins were observed in aqueous solutions of the particles with different particles concentrations by using a magnetic resonance imaging (MRI) scanner, which showed that the $T_1$ and the $T_2$ relaxivities of the particles in water were $0.57mM^{-1}{\cdot}s^{-1}$ and $10.42mM^{-1}{\cdot}s^{-1}$, respectively. In addition, using an induction heating system, we evaluated their potentials for magnetic hyperthermia applications. The aqueous solution of the particles with a moderate concentration (smaller than 6.5 mg/mL) showed a saturation temperature larger than the hyperthermia target temperature of $42^{\circ}C$. These findings show that the CTAB-coated nickel ferrite particles are suitable for applications as $T_2$ contrast agents in MRI and heat generators in magnetic hyperthermia.

초음파 Hyperthermia에 의한 종양모델내의 동적 온도분포 추정 (The Estimation of Transient Temperature Distributions in Tumor Model during Ultrasonic Hyperthermia)

  • 박태연;성굉모
    • 한국음향학회지
    • /
    • 제5권4호
    • /
    • pp.46-56
    • /
    • 1986
  • Hyperthermia를 사용하여 종양세포를 치료하는데 있어서 시간에 따른 동적 온도분포를 추정하 고 또, 그 온도분포에 관계하는 인자들이 동적 온도특성에 미치는 영향을 살펴보는 것은 실제 치료시에 정확한 온도제어를 위해서 반드시 필요하다. 본 논문에서는 몸속 10cm 깊이에 존재하는 원통형 종양모 델을 설정하고 초음파 동심환 변환기로 열을 집속시켰을 때 동적 온도분포 추정을 위해서 2차원 유한요 소법과 유한차분법을 이용하였다. 결과로서, 동적 온도분포에 가장 큰 영향을 미치는 인자는 혈류량이었 고, 추출된 동적 온도분포 특성값을 가지고 간단한 ON/OFF 온도제어에 적용할 수 있음을 보였다.

  • PDF

초음파 Hyperthermia용 동심환 변환기의 설계에 관한 연구 (A Study on the Design of an Annular Array Transducer for Ultrasonic Hyperthermia)

  • 조영환;성굉모
    • 한국음향학회지
    • /
    • 제5권4호
    • /
    • pp.37-45
    • /
    • 1986
  • 초음파 Hyperthermia를 이용한 치료는 정상세포에 열적 손상을 주지 않으면서 종양 부위만을 적당한 온도로 가열하여야 하며 따라서 종양세포와 정상세포에 대한 정확한 초음파 세기조절이 필요하 게 된다. 본 논문에서는 초음파 Hyperthermia 용 변환기로서 초점거리와 가열범위를 전자적으로 쉽게 조절할 수 있는 동심환 배열 변환기를 설계하였으며 컴퓨터 모의 실험을 통해 그 성능을 예측하였다. 설계된 변환기는 유효직경 118mm, 동작주파수 320kHz 이며 배열 요소의 수는 12개이다. 그리고 이와 같은 동심환 변환기를 동작시키기 위해 카운터를 이용한 디지털 위상 조절 회로를 설계 제작하였으며, 실험 결과, 위상차를 갖는 신호를 발생시킬 수 있었다.

  • PDF

암치료를 위한 고주파 온열장치의 개발과 가온특성 (Thermal Distribution and Development of RF Hyperthermia for Cancer Treatment)

  • 추성실;김귀언
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권1호
    • /
    • pp.63-68
    • /
    • 1987
  • The biological effects for the use of hypertherinla to treat malignant tumors has been well studied and encouraging clinical results have been reported. However, the engineering and technical aspects of hyperthermia for the deepseated tumors has not been satisfactory. We have developed the FF capacitive hyperthermia device(GHT RF8)by cooporation with Yonsei Cancer Center and Green Cross Medical Equipment Corporation. It was composed with 8.10 MHz RF generator, capacitive electrode, matching system, cooling system, temperature measuring thermocouples and control PC computer. We have measured the temperature and thermal distribution in agar phantom, animals and human tumors.

  • PDF

1차원 유한요소법 모델을 이용한 초음파 Hyperthermia의 온도분포에 관한 연구 (A Study on the Estimation of Temperature Distribution in Ultrasonic Hyperthermia by 1-Dimensional FEM Model)

  • 하재규;성굉모
    • 한국음향학회지
    • /
    • 제6권1호
    • /
    • pp.29-38
    • /
    • 1987
  • Hyperthermia의 임상 응용에서 측정할 수 있는 온도치는 수 점의 온도치로 제한되는데 효과적인 치료를 위해서는 그 외의 점에서의 정확한 온도분포를 알아야 할 필요가 있다. 이를 위하여, 본 논문에서는 생체 열전달 방정식을 1차원 2경계치 문제로 단순화시켜 계산시간을 줄였으며 Galerkin법을 이용하여 그 근사해률 구하였다. 그 결과를 동심환 초음파 변환기에 적용하여 축방향의 온도분포를 계산하였으며 측정된 수 점의 온도로부터 축방향의 온도분포를 추정할 수 있는 알고리즘을 제시하였다.

  • PDF

자기 온열 시스템의 열 발생 효율에 관한 실험적 연구 (The Experimental Study of Heat Generation Efficiency of Magnetic Hyperthermia System)

  • 송영진;오정환
    • 한국연소학회지
    • /
    • 제16권2호
    • /
    • pp.33-39
    • /
    • 2011
  • We demonstrated heat generation efficiency of the magnetic hyperthermia system to find optimal condition using gelatin tissue phantom. Magnetic hyperthermia induction can be used to make heat generation with different concentration of $Fe_3O_4$ iron oxide inside tissue phantom and magnetically labeled cells by applying AC magntic field at a frequency of 145 kHz. It was observed that the maximum temperature achieved in the magnetic gelatin tissue phantom increased with the concentration of $Fe_3O_4$ iron oxide and alternating magnetic field intensity. Results were discussed with respect to further optimization of therapeutic technique for biomedical application with modified functional nanoparticles.