• Title/Summary/Keyword: hydrogen refueling

Search Result 103, Processing Time 0.023 seconds

Experimental and Analytical Study on Hydrogen-air Deflagrations in Open Atmosphere (개방 공간에서 발생하는 수소-공기 혼합 가스 폭연에 대한 실험적/해석적 연구)

  • Kim, Yangkyun;Park, Byoung Jik
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.1
    • /
    • pp.64-71
    • /
    • 2021
  • Experimental and analytical investigations are performed to explore the explosion characteristics of a hydrogen-air mixture in open atmosphere. A hydrogen-air mixture tent of total volume of 27 m3, with 40% hydrogen volume, is used to observe overpressure at a distance from the ignition source. Vapor cloud explosion analyses are performed using the TNO multi-energy model and Baker-Strehlow-Tang model. The results of these analyses are compared with experiment done from this study and references. The experimental results with and without obstacles indicate that the overpressure values measured at a distance of 4.5-21.5 m from the ignition source are about 9.4-3.6 kPa and 6.5-2 kPa, respectively. This implies that the overpressure with obstacles is approximately 1.7 times greater than that without obstacles. Analytical observation indicates that the results obtained with the Baker-Strehlow-Tang model with Mf = 0.2-0.35 are in good agreement with those of most of the previous studies, including that obtained from this study. Moreover, the TNO multi-energy model with a volume of 27 m3 well predicts the overpressure obtained from this study. Further studies should considered explosions in semi-confined spaces, which is more suitable for hydrogen refueling stations.

A Study on Taxonomy and RCM Strategy Establishment for Performance Evaluation of Hydrogen Compression System at Hydrogen Vehicle Refueling Stations (수소자동차충전소의 수소압축장치 성능평가를 위한 분류체계 및 RCM 전략수립 연구)

  • Seong-jun Bae;Ha-neul Yim;Seo-yeon Na;Chung-keun Chae;Jin-hyeok Choi;Jin-woo Lee;Sang-bong Shin
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.48-56
    • /
    • 2023
  • Currently, Hydrogen compressor is maintained and managed according to the safety management regulations of the operator. But it is not based on technical standards, so it is necessary to establish based on reliability. In this paper, hydrogen compressor taxonomy by ISO 14224 standard reviewed for hydrogen compressor operated by KOGAS-Tech hydrogen vehicle refueling station to establish 9-stage taxonomy, and FMEA was conducted to establish RCM strategy specified in SAE JA1011, and 1012. It is expected that results of taxonomy and RCM strategy will be used as basic data for development of standards for verifying the performance of compressors.

Economic Analysis Program Development for Assessment of Hydrogen Production, Storage/Delivery, and Utilization Technologies (수소 전주기 경제성 분석 프로그램 개발)

  • SUHYUN KIM;YOUNGDON YOO;HYEMIN PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.607-615
    • /
    • 2022
  • In this study, economic analysis program was developed for economic evaluation of hydrogen production, storage/delivery, and utilization technologies as well as overseas import of hydrogen. Economic analysis program can be used for the estimation of the levelized cost of hydrogen for hydrogen supply chain technologies. This program include five hydrogen production technology on steam methane reforming and water electrolysis, two hydrogen storage technologies (high compressed gas and liquid hydrogen storage), three hydrogen delivery technologies (compressed gas delivery using tube trailer, liquid hydrogen, and pipeline transportation) and six hydrogen utilization technologies on hydrogen refueling station and stationary fuel cell system. In the case of overseas import hydrogen, it was considered to be imported from five countries (Austraila, Chile, India, Morocco, and UAE), and the transportation methods was based on liquid hydrogen, ammonia, and liquid organic hydrogen carrier. Economic analysis program that was developed in this study can be expected to utilize for planning a detailed implementation methods and hydrogen supply strategies for the hydrogen economy road map of government.

Radiation Exposure Reduction in APR1400

  • Bae, C.J.;Hwang, H.R.;Matteson, D.M.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.2
    • /
    • pp.127-135
    • /
    • 2003
  • The primary contributors to the total occupational radiation exposure in operating nuclear power plants are operation and maintenance activities doting refueling outages. The Advanced Power Reactor 1400 (APR1400) includes a number of design improvements and plans to utilize advanced maintenance methods and robotics to minimize the annual collective dose. The major radiation exposure reduction features implemented in APR1400 are a permanent refueling pool seal, quick opening transfer tube blind flange, improved hydrogen peroxide injection at shutdown, improved permanent steam generator work platforms, and more effective temporary shielding. The estimated average annual occupational radiation exposure for APR1400 based on the reference plant experience and an engineering judgment is determined to be in the order of 0.4 man-Sv, which is well within the design goal of 1 man-Sv. The basis of this average annual occupational radiation exposure estimation is an eighteen (18) month fuel cycle with maintenance performed to steam generators and reactor coolant pumps during refueling outage. The outage duration is assumed to be 28 days. The outage work is to be performed on a 24 hour per day basis, seven (7) days a week with overlapping twelve (12) hour work shifts. The occupational radiation exposure for APR1400 is also determined by an alternate method which consists of estimating radiation exposures expected for the major activities during the refueling outage. The major outage activities that cause the majority of the total radiation exposure during refueling outage such as fuel handling, reactor coolant pump maintenance, steam generator inspection and maintenance, reactor vessel head area maintenance, decontamination, and ICI & instrumentation maintenance activities are evaluated at a task level. The calculated value using this method is in close agreement with the value of 0.4 man-Sv, that has been determined based on the experience aid engineering judgement. Therefore, with the As Low As Reasonably Achievable (ALARA) advanced design features incorporated in the design, APR1400 design is to meet its design goal with sufficient margin, that is, more than a factor of two (2), if operated on art eighteen (18) month fuel cycle.

Plan to Promote the Supply of Hydrogen City Buses in Busan (부산시 수소시내버스 보급 활성화 방안 연구)

  • LEE, WONGYU
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.309-317
    • /
    • 2022
  • There are 2,517 buses on 143 routes in Busan. One company is operating 36 hydrogen city buses (1.4%) and two hydrogen charging stations. By 2030, the number of hydrogen city buses will be increased to 500 and 40 hydrogen charging stations. In the survey of city bus companies, 61.5% of respondents answered 'not reviewing (at all)' and 23.0% of respondents '(actively) reviewing hydrogen buses'. And as for the level of help that hydrogen city buses give to bus companies, 23.5% answered 'helpful'. In order to promote the introduction of hydrogen city buses, first, it is necessary to stipulate support for hydrogen bus purchase cost and hydrogen charging station construction cost in related ordinances so that bus companies do not increase their burden of purchasing hydrogen buses in the future. Second, identify the number of new city buses introduced, convert about 50% to hydrogen city buses by the mid-term, and build 50% of the chargers in public garages with hydrogen chargers. Third, expand hydrogen refueling stations in city bus garages.

Calculation and Comparison of Thermodynamic Properties of Hydrogen Using Equations of State for Compressed Hydrogen Storage (상태방정식을 이용한 고압수소 저장을 위한 수소 열역학 물성 계산 및 비교)

  • PARK, BYUNG HEUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.2
    • /
    • pp.184-193
    • /
    • 2020
  • One of the technical methods to increase the volumetric energy density of hydrogen is to pressurize the gaseous hydrogen and then contain it in a rigid vessel. Especially for automotive systems, the compressed hydrogen storage can be found in cars as well as at refueling stations. During the charging the pressurized hydrogen into a vessel, the temperature increases with the amount of stored hydrogen in the vessel. The temperature of the vessel should be controlled to be less than a limitation for ensure stability of material. Therefore, the accurate estimation of temperature is of significance for safely storing the hydrogen. In this work, three well-known cubic equations of state (EOSs) were adopted to examine the accuracy in regenerating thermodynamic properties of hydrogen within the temperature and pressure ranges for the compressed hydrogen storage. The formulations representing molar volume, internal energy, enthalpy, and entropy were derived for Redlich-Kwong (RK), Soave-Redlioch-Kwong (SRK), and Peng-Robinson (PR) EOSs. The calculated results using the EOSs were compared with literature data given by NIST. It was revealed that the accuracies of RK and SRK EOSs were satisfactorily compatible and better than the results by PR EOS.

A Study on a Combined DMFC-Lithium Battery Hybrid System for a Forklift (지게차용 DMFC와 리튬배터리 하이브리드시스템의 혼합 적용에 대한 연구)

  • Ju, Yong-Soo;Lim, Dong-Jin;Kim, Hong-Gun;Kwac, Lee-Ku
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.57-65
    • /
    • 2021
  • This paper explains a DMFC-Lithium Battery hybrid system applied to a forklift. A conventional Lead Acid battery forklift has several problems: long charging times, short operation times, and frequent battery replacements. As a result, hydrogen-powered forklifts are replacing Lead acid battery-powered forklifts due to their shorter refueling time and longer operation times. However, in doing so, we are confronted with the problem of a high hydrogen refueling infrastructure. A Direct Methanol Fuel Cell (DMFC), on the other hand, is an eco-friendly generator that directly converts the chemical energy of methanol into electricity. In general, DMFC is regarded as a small power generator under kW power. In this paper, a DMFC-Battery hybrid system is applied to a 1.5 ton forklift by increasing the power output of the DMFC stack and utilizing the high charge-discharge characteristics of a lithium battery.

Current Status of Standardization of ISO TC197 (수소에너지에 대한 ISO 표준화 동향과 시사점)

  • KIM, JONG-WON;LEE, TAECKHONG;CHOI, JAE-WOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.3
    • /
    • pp.245-255
    • /
    • 2016
  • Commercial production line of FCEV was built in 2013 by Hyundai and followed by Toyota in 2014, with additional manufacturers planning to enter the market around 2017. Now there is limited hydrogen infrastructure over the world, but more hydrogen stations are planned, particularly in Japan, Korea, Germany, UK and USA. ISO TC 197 which was created in 1990 focused standardization in the field of systems and devices for the production, storage, transport, measurement and use of hydrogen. Total number of published ISO standards related to the TC and its SCs (number includes updates) is 17. Now there are 20 participating countries and 13 observing countries. The current status of activity of ISO TC197 was reviewed and particularly issues on hydrogen quality and hydrogen refueling station were discussed.

A Study on Hydrogen Energy Safety according to the Revitalization of the Hydrogen Economy (수소경제 활성화에 따른 수소에너지 안전성 고찰)

  • Park, Woo-Il;Tak, Song-Su;Lee, In-Woo;Hong, Soon-Pa
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.74-79
    • /
    • 2021
  • This study analyzed the current status of the global hydrogen economy and the safety of energy sources currently in use due to the activation of the hydrogen economy. Understanding the hydrogen economy, identifying government policy trends, comparing and analyzing characteristics with existing energy sources such as gasoline, propane, and methane, and evaluating damage impact for each energy source using PHAST, a quantitative damage impact assessment program. Using the analysis results, this study analyzes the safety of hydrogen energy to revitalize the hydrogen economy and suggests ways to improve safety.

A Study on the Safety Enhancement of Hydrogen Tube Trailer (수소운송설비 안전성 강화 방안 고찰)

  • Woo-Il, Park;Yeong-Hun, Kim;In-Woo, Lee;Seung-Kyu, Kang
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.6
    • /
    • pp.59-64
    • /
    • 2022
  • Currently, 787 hydrogen tube trailer are in operation as of the end of October 2022, and a maximum of 340 kg is transported in a Type 1 seamless container at a pressure of up to 200 bar. The current safety management system and facility management are in good condition, but the system and facility structure improvement are needed to strengthen safety. Accordingly, this paper simulated and analyzed an accident case that occurred on the Daejeon-Dangjin highway on December 28, 2021 during the process of expanding the supply and operation of hydrogen tube trailer according to the hydrogen energy activation policy. Based on the results, suggestions were made on how to improve the safety of hydrogen tube trailer.