• 제목/요약/키워드: heat insulation

검색결과 891건 처리시간 0.024초

강원도지역의 토양 동결심 및 상록식물의 함수량 추이에 관한 연구 (2) (Studies on the Soil Freezing Depth and Change of Moisture contents in evergreen Plants upon subzero Temperature in Kangwon area.(2))

  • 홍종운;허범양;원경열;임병춘;이기철;하상건
    • 아시안잔디학회지
    • /
    • 제4권1호
    • /
    • pp.49-55
    • /
    • 1990
  • Experiments were conducted to investigate the relationships between the soil freezing depth and the accumulated degree-day of temperature below $0^{\circ}C$ at 17 locations during 1989-1990 winter season in kangwon province. The observed results are as follows : 1.When accumulated degree-day of temperature below at was 141t at late January soil freezing depth of sunny place was 46.5cm, that of shaded lot was 59 cm, and that of marginal place sunny or shaded area was 55cm, in Chun cheon. 2.Accumulated degree-day of temperature below at of Dae gwangryong area was more than that of Un-du, whereas soil freezing depth of Dae gwangryong was lower that of Un-du. It was considered that snow covering worked as heat insulator. 3.Soil freezing depth of vinyl mulching on Zoysia turf was less by around 2Ocm than that of non-vinyl mulching. Rice hulls covering of 4Ocm showed the great heat insulation effects with the soil freezing depth of 1.5cm at sunny place and 6.5cm at shaded lot compared to that of 47cm at sunny and 59.5 cm at shaded place bare ground. 4.Among investingated areas, Dunae, Honeg seong gun was the deepest soil freezing, 89cm with $569^{\circ}C$ of accumulated degree-day of temperature below $0^{\circ}C$ at late February. 5.dehydration of Juniperus C. var. Kaizuca, Euonymus japonica, and Chamaecyparis pisifira at winter season was around 5 %, however dehydration of Vinca minor was more than 10 %. A Studies on the Soil Freezing Depth and Change of Moisture contents in evergreen Plants upon subzero Temperature in Kangwon area.(2)

  • PDF

신한옥의 쾌적성능 평가: 전남 화순 잠정햇살마을 한옥단지를 대상으로 (Evaluation of Comfort Performance for Modernized Hanok: Targeting Hanok Residence at the Jamjeong-Haetsal Village in Hwasun, Jeonnam Province)

  • 최승주;이미향;김재향;한승훈
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.99-108
    • /
    • 2021
  • 이 연구의 목적은 한옥 거주환경의 쾌적성능에 대한 정량적 자료를 제시하고 개선 요인을 도출하는 데 있다. 먼저 정책적 성공사례로서 현대(신(新))한옥의 하나인 전남 화순군 잠정햇살마을 한옥단지를 대상으로 건구온도, 복사온도, 상대습도, 풍속 등 열쾌적성 평가의 영향 요소를 측정했다. 이어 도출 데이터를 적용하여 PMV(Predicted Mean Vote)를 산출하는 열환경 시험을 수행했으며, 사용자 대사율과 의복량을 변수로 설정하여 L.C.PMV(Life-Cycle PMV)와 N.PMV(Normal PMV)의 두 가지 유형으로 구분하여 평가를 진행했다. 그 결과, 여름 및 겨울철 시점을 전후하여 한옥 공간의 PMV 증감 동향이 뚜렷했으며, 특히 대서 및 대한 시점의 PMV는 쾌적구간을 완전히 벗어난다는 시험 결과를 확인했다. 아울러 겨울철 PMV의 변화 속도가 여름철보다 더 빠른 것으로 나타났다. 이러한 결과를 통해 신한옥의 쾌적성능 증진을 위해 단열성 개선이 우선 요인임이 도출되었으며, 설계 및 시공 단계에서 연계 검토가 요구된다.

액화수소 저장탱크의 수평요동이 증발 특성에 미치는 영향에 대한 연구 (A Study on the Effect of Evaporation of Liquid Hydrogen Tank Related to Horizontal Sinewave)

  • 오승준;권준영;윤정환
    • 한국수소및신에너지학회논문집
    • /
    • 제34권2호
    • /
    • pp.155-161
    • /
    • 2023
  • Recently, a study on alternative and renewable energy is being conducted due to energy depletion and environmental problems. In particular, a hydrogen has the advantage of converting and storing the remaining energy into water-electrolyzed hydrogen through renewable energy generation. In general, due to reasons such as insulation problems, a study on high-pressure hydrogen storage tanks and related parts has recently been conducted. However, in the case of liquid hydrogen, the volume can be reduced by about 800 times or more compared to high-pressure hydrogen gas, so the study on this is needed as a technology that can increase energy density. In this study, the evaporation characteristics were analyzed under fixed heat flux conditions for liquid hydrogen storage tanks and the change in thermal stratification according to sloshing was analyzed. The heat flux condition was fixed at 250 W/m2 and the horizontal resonance frequency of the primary mode was applied to the storage tank. As a result, it was confirmed that the thermal stratification phenomenon decreased compared to the case where the slashing was not present due to forced convection when the slashing was present.

건설업 직종별 노출 가능 유해인자 및 노출강도에 관한 평가 (Evaluation on Probability and Intensity of Hazards Exposure by Construction Occupations)

  • 박현희;김세동
    • 한국산업보건학회지
    • /
    • 제33권3호
    • /
    • pp.317-331
    • /
    • 2023
  • Objectives: Construction workers are exposed to various hazardous substances simultaneously. However, little is known about the exposure hazards in construction industry. This study was aimed at identifying the risk of exposure hazards among construction workers. Methods: The expert survey (n=29) was conducted, including construction industry health managers (n=11) and work environment monitoring experts (n=18), on exposure probability, intensity and risk of hazardous substances by construction occupations Results: The exposure hazards of 30 construction occupations were identified and summarized through a literature review and expert survey. The most prevalent hazards were in order of noise, awkward posture, heat/cold, crystalline silica, cement/concrete dust, metal fumes, and volatile organic compounds. The hazards with highest risk score(over seven points) at construction occupations were noise(formwork carpenter, concrete finisher, rebar worker, demolition worker, driller/rock blaster), hazardous rays(welder), heat/cold (earthworks, formwork carpenter, rebar worker, concrete placer, scaffolder), awkward posture(bricklayer, caulker/tile setter, rebar worker) and heavy lifting(bricklayer, rebar worker). Among construction workers, the job types with the highest risk of exposure to carcinogens, and in which occupational cancer has been reported, were in order of stonemason, concrete finisher, rock blaster, welder, insulation installer, painter, scaffolder, plant worker and earthworks in order Conclusions: Systematic research and discussion on occupational disease among construction workers and its various hazardous factors are needed to establish job exposure matrix for facilitating standard for promptly processing the workers' compensation.

온실용 이중피복 및 보온재의 관류열전달계수 산정을 위한 수치적 연구 (A Numerical Study for Calculation of Overall Heat Transfer Coefficient of Double Layers Covering and Insulation Material for Greenhouse)

  • 이종원;김동건;이현우
    • Current Research on Agriculture and Life Sciences
    • /
    • 제33권2호
    • /
    • pp.41-47
    • /
    • 2015
  • 본 연구는 온실용 피복재 및 보온재의 조합에 대한 시뮬레이션 해석모델을 개발하여 관류열전달계수를 산정하고 측정된 결과와 비교하여 타당성을 평가하기 위해 수행되었으며 결과를 요약하면 다음과 같다. 유리이중피복의 경우 이중피복 사이의 공기층이 두꺼워짐에 따라 관류열전달계수가 서서히 작아져서 공기층 두께가 25 mm 이상이 되면 관류열전달계수의 변화가 거의 없는 것을 확인할 수 있었다. 또한 온도차가 증가함에 따라 관류열전달계수도 증가하는 것을 확인할 수 있었다. 두 플라스틱 피복재 사이에는 대류에 의한 열전달이 활발하게 일어나기 때문에 비정상 유동에 의한 열전달이 발생하고 이로 인해 온도분포도 비선형적으로 변하는 것으로 사료된다. 플라스틱 피복재 및 보온재들의 간격이 50~200 mm범위에서 변화할 때에 피복재의 간격은 관류열전달계수 큰 영향을 미치지 않는다는 사실을 확인할 수 있었다. 천공복사를 고려한 경우와 고려하지 않은 경우 모두 핫박스의 내외부 온도차가 $30^{\circ}C$인 조건에 대해서는 수치해석결과와 실험결과가 대체로 잘 일치하였다. 따라서 핫박스의 내외부 온도차가 $30^{\circ}C$ 이상인 조건에서 수치해석을 통해 관류열전달계수를 산정한다면 신뢰성 있는 값을 얻을 수 있을 것으로 판단된다.

흰쥐 Tail Flick Reflex의 신경생리학적 기전 (Electrophysiologic Mechanism of Tail Flick Reflex in Rats)

  • 서상아;김전
    • The Korean Journal of Physiology
    • /
    • 제23권1호
    • /
    • pp.139-149
    • /
    • 1989
  • Although tail flick reflex (TFR) in rats has been used as a classic model of the nociceptive test to evaluate the action of analgesics, there have been few studies on the origin of the latent period of TFR. Present study was performed to elucidate the mechanism of increase in latency of TFR by morphine in anesthetized rats. Tail skin and dorsolateral tail nerve were stimulated electrically and EMG activities were recorded from abductor caudae dorsalis muscle participating in tail flick reflex. In the case of noxious radiant heat stimulation to tail, the tail flick tension was recorded before and after administration of morphine. Then changes in latency and conduction velocity of peripheral nerve were evaluated. The results obtained were as follows: 1) The latencies of TFR evoked by the electrical stimulation of tail skin and dorsolateral tail nerve were all within 40 ms and were elongated by several milliseconds from control after the administration of morphine. Peripheral conduction velocities of tail flick afferent nerve were within the range of 10-25 m/s. 2) The conduction velocity of peripheral nerve was significantly reduced after morphine administration, therefore the afferent time (utilization time+conduction time to spinal cord) was significantly increased. But the time for central delay and efferent time was not affected by morphine. 3) The conduction velocity under room temperature $(20-25^{\circ}C)$ was significantly reduced after morphine while that under vasodilation state $(40{\sim}42^{\circ}C)$ increased, 30 min and 45 min after morphine. The conduction velocity under vasodilation state without treatment of morphine increased continuously 4) The latency in tension response of TFR evoked by electrical stimulation was elongated by several milliseconds from control while the latency evoked by noxious radiant heat was elongated by several seconds compared with that of control. From the above results, it could be concluded that: 1) the increased latency of TFR evoked by electrical stimulation of the tail after morphine administration was due to the reducton in conduction velocity of peripheral nerve, which was the secondry effect of morphine on the peripheral vasomotion and 2) increased latency of TFR evoked by noxious radiant heat was also due to the same effect of morphine and the increase in cutaneous insulation to the noxious heat.

  • PDF

폐유리의 가수분해 반응에 의한 발포유리의 제조(III) - 안정화 열처리공정 및 Scale-up Test - (Production of Foamed Glass by Using Hydrolysis of Waste Glass(III) - Heat Treatment for Stabilization and Scale-up Test -)

  • 이철태;엄의흠
    • 공업화학
    • /
    • 제17권1호
    • /
    • pp.73-81
    • /
    • 2006
  • 가수분해시킨 폐 유리를 사용하여 발포유리블록의 제조시 발포유리블록의 안정화를 위한 열처리 공정을 조사하였으며 이를 바탕으로 상업적 생산을 위한 scale-up 실험을 시도하였다. 최적의 열처리 조건은 발포소성 후 $550{\sim}600^{\circ}C$로 급냉시켜 안정화시키고 이후 $200^{\circ}C$에서 추가적으로 열응력을 해소하고 $0.3^{\circ}C/min$의 속도로 실온까지 냉각시키는 것이다. 이러한 열처리 조건을 거침으로서 기계적으로 안정성을 지닌 $250mm{\times}250mm{\times}90mm$ 크기의 발포유리가 생산 가능하였으며 이 경우 발포유리블록의 물성은 밀도 $0.28{\pm}0.06g/cm^3$, 열전도도 $0.048{\pm}0.005kcal/hm^{\circ}C$, 흡수율 $0.5{\pm}0.09vol%$, 선팽창계수$(8.6{\pm}0.2){\times}10^{-6}m/m^{\circ}C$($400^{\circ}C$ 기준), 휨강도 $15.0{\pm}0.6kg/cm^2$, 압축강도 $39.5{\pm}0.6kg/cm^2$의 특성을 갖는 것으로 확인되었다.

블라인드 내장형 창호시스템의 에너지 성능 및 경제성 평가에 관한 연구 (Study on Energy Performance And Economic Evaluation of Windows System with Built-in Type Blinds)

  • 조원화;임남기
    • 한국건축시공학회지
    • /
    • 제10권2호
    • /
    • pp.97-104
    • /
    • 2010
  • 본 연구에서는 전열해석 프로그램인 피지벨(PHYSIBEL)을 사용하여 블라인드 내장형 창호시스템의 일사차단성능 및 단열성능에 따른 에너지 성능을 평가하였다. 피지벨 해석시 창호별 구성 재료의 열적특성과 해석조건을 결정하기 위해서 Mock-up시험을 실시하였으며, 컴퓨터 시뮬레이션을 통한 결과를 바탕으로 공동주택 기준층 1개 세대(33평형)를 대상으로 연간에너지 소비특성, 연간전열량, 연간 냉난방 비용을 분석하였다. 실험결과, 연간전열량은 일반 창호시스템 대비 블라인드 내장형 창호시스템에서 블라인드를 올린 경우 냉방시 10%, 난방시 11% 절감할 수 있으며, 블라인드를 내린 경우 냉방시 25%, 난방시 30%정도를 절감할 수 있는 것으로 나타났다. 블라인드 내장형 창호시스템의 냉 난방 부하 절감량은 일반 창호시스템에 비해 냉방시 283.3KWh, 난방시 76.3KWh 로 냉 난방 에너지 절감효과는 단위세대당 359.6KWh 절감시킬 수 있는 것으로 나타났으며, 이것은 단위세대당 연간 에너지원단위(TOE) 약 0.078toe, 이산화탄소톤($tCO_2$) $0.16tCO_2$을 절감시킬 수 있어 온실가스 저감에도 유리할 것으로 판단된다. 또한, 블라인드 내장형 창호시스템의 냉 난방비용 절감액은 일반창호시스템과 비교하여 연간 냉방비용 10만원, 난방비용 5만원으로 연간 냉 난방 비용을 약 15만원 정도 절감시킬 수 있는 것으로 나타났다.

단열용기의 잠열재 배치에 따른 내부 온도 균일성에 대한 영향 (Effect of Latent Heat Material Placement on Inside Temperature Uniformity of Insulated Transfer Boxes)

  • 지형용;정동열;최석천;김정열
    • 한국포장학회지
    • /
    • 제29권1호
    • /
    • pp.27-33
    • /
    • 2023
  • 본 연구에서는 저온물류 시스템의 단열용기의 온도유지 성능에 대하여 5℃급 저온 LHM을 배치하였을 때 배치구성 조건에 따른 온도특성을 확인하였다. LHM을 단열용기 내부에 배치하였을 때 6면과 5면에 상/하부 배치 비중에 차이를 두고 외기부하에 따른 내부 공기 온도균일도 및 목표 온도 유지시간을 분석하였다. 단열용기 내부 공기는 상부의 상승온도와 이때 발생하는 밀도차에 의한 공기 대류현상이 온도 성층화를 발생시키고, 균일도를 확보하기 위해 LHM의 상부 배치 비중이 하부보다 컸을 때 균일성이 높고 유지 시간이 오래 지속되는 것을 확인하였다. 다만, 상부 배치 비중을 높이기 위해 하부 배치를 제외한 조건에서 높은 균일성을 보이지만 짧은 유지 시간으로 보여 적정조건으로 알맞지 않다. 결과적으로 단열용기의 단열재 대칭구성과 LHM의 동일한 중량을 배치하여 보냉용기를 제작할 경우, LHM의 전면 배치를 바탕으로 하부에 비해 상부 배치 비중을 늘렸을 때 내부 공기 온도의 분포 균일도와 유지시간 성능을 높이는데 효율적인 방안이라고 판단된다. 저온물류 보냉용기 성능분석에 있어, 본 연구를 기반으로 다른 조건의 상변화 온도와 잠열량을 갖는 다양한 저온영역대의 LHM을 적용한 수치해석을 수행하여 성능 예측 결과를 확보할 수 있고 온도 균일도를 위한 단열 및 잠열 복합 구성 이송 용기의 최적 설계조건 수립에 기여할 것으로 기대된다.

평가시공불량을 모의한 배전급 케이블 종단부의 전기적 사고 연구 (A Study on Electrical Accident of Distributing Cable Termination with Simulated Badness Construction)

  • 최재형;최진욱;김상현;김영석;김선구;백승명
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.465-470
    • /
    • 2008
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated badness construction. We prepared two termination kites, one is built-up type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and measured their insulation characteristics such as ac (35kV, 1min) and impulse (95kV, $1.2{\times}50{\mu}s$) withstand test. The influence of defects such as thickness and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness decrease of insulator decreases ac breakdown strength. Dielectric breakdown traces of insulator that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of insulator seriously.

  • PDF