Abstract
This study evaluated the energy efficiency of a windows system using built-in blinds, with regard to their insulation performance and their blocking of solar radiation. The study took advantage of the "Physibel Voltra" program as a physical simulation of heat transfer. To simulate the "Physibel Voltra" program, I practiced a mock-up test to determine heating quality and translation condition. I analyzed the propensity to annual energy consumption, the annual quantity of heat transfer, and the annual cooling and heating cost through a computer simulation for one general household in an apartment building. In the test, it was found that compared to a general windows system, a windows system with built-in blinds reduced the annual heat transfer by 10% in cooling states and by 11% in heating states when the blind was up. When the blind was down, the windows system with built-in blinds reduced the annual heat transfer by 25% in cooling states and 30% in heating states. When a windows system with built-in blinds is compared with a general windows system, the quantity of cooling and heating loads is reduced by 283.3kw in cooling states and 76.3kw in heating states. This leads to a reduction in the required cooling and heating energy of 359.6kw per house. It is thus judged that the use of a windows system with built-in blinds is advantageous in terms of reducing greenhouse gas emissions, because the annual TOE (tons of oil equivalent) per house is reduced by 0.078TOE, while $tCO_2$ is reduced by $0.16tCO_2$. In addition, compared with a general windows system, the cost of cooling and heating loads in the system reduces the annual cooling cost by 100,000won, and the annual heating cost by 50,000won. Ultimately, this means that cooling and heating loads are cut by 150,000won per year.
Keywords
Blinds; Built-in Type; Windows System; Energy Performance;
Citations & Related Records
연도 인용수 순위
  • Reference
1 박효순, 주택.건물부문의 에너지절약 동향 분석 - 신기술.운영시스템중심으로-, 2006
2 에너지관리공단, 건물 에너지절약을 위한 제도 개선 연구, 2000
3 에너지관리공단, 저탄소 녹색성장을 위한 에너지절약 실천 매뉴얼,2008
4 에너지관리공단, 주택.건설부문 新 고유가 대응 전략 포럼, 2006
5 정환교, 창호시스템이 실내온도 및 건물의 에너지 소비량에 미치는 영향에 관한 연구, 2007
6 최보혜, 최경석, 김경우, 강재식, 이승언, 차양일체형 창호시스템 적용에 따른 공동주택 에너지 성능평가 연구, 대한건축학회 학술발표대회 논문집, 2009
7 한국건설기술연구원, 건축물의 에너지효율화 강화방안 연구 -2004 정책연구과제-, 2004
8 한국산업규격 KS F 2278-'08 : 창호의 단열성 시험방법
9 ASHRAE, ASHARA/IEA Standard 90.1-2001 Energy Standard for Buildings Except Low-Rise Residential Buildings, 2001
10 ASHRAE, ASHRAE Handbook 1997 Fundamentals, 1997
11 국토해양부, 건축물의 에너지절약 설계기준, 2008
12 김수미, 주거건물의 창호시스템 구성요소 조합별 평가를 통한 단열성능 향상방안에 관한 연구, 2006