• 제목/요약/키워드: handpiece

검색결과 99건 처리시간 0.033초

대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태 (Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu)

  • 은정화;배지영
    • 한국치위생학회지
    • /
    • 제5권2호
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

초음파 절삭기 핸드피스부 제작 및 변위 특성 시뮬레이션 (Fabrication and Simulation of Displacement Properties of Ultrasonic Generator Handpiece)

  • 김승원;류주현;이지영
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.152-155
    • /
    • 2018
  • Ultrasonic wave technologies have been widely used in ultrasonic washing machines, ultrasonic surgery, ultrasonic welding machines, ultrasonic sensors, and medical instruments. Ultrasonic surgery can be realized through the cavitation effect of ultrasonic waves. In this study, piezoelectric ceramics were manufactured to achieve the optimum design of a piezoelectric vibrator in a handheld generator for ultrasonic surgery. The best specimen showed the excellent piezoelectric properties of kp=0.624, Qm=1,531, and $d_{33}=356pC/N$. Numerical modeling based on the finite element method was performed to find the resonance frequency, the anti-resonance frequency, and the displacement properties of the handheld ultrasonic generator. Maximum displacement was observed in the six-step piezoelectric vibrator at $6.36{\mu}m$.

마이크로 모터 핸드피스를 위한 BLDC 전동기 제어시스템 개발 (A Development of the Control System of BLDC Motor for Micro Motor Handpiece)

  • 백원식;송현직;김민회;김동희;이헌욱;황돈하
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 2008
  • The permanent magnet BLDC motors are increasingly being used in high performance applications due to the high torque density and simplicity in their control. In this paper, the control system of the BLDC motor is developed which can be used for the micro motor handpiece, and position sensorless control is realized using back EMF measurement scheme, The validity and practical applications of the developed slotless BLDC motor and drive system are verified through the experimental results.

  • PDF

의료용 고속 에어터빈 핸드피스의 내부 유동특성에 대한 수치해석 (NUMERICAL ANALYSIS OF INTERNAL CHARACTERISTICS ON DENTAL HIGH-SPEED AIR TURBINE HANDPIECE)

  • 류경진;윤동협;백준호;이동우;김동영;장상우;송동주
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.535-542
    • /
    • 2011
  • To utilizing CFX V12.0.l, internal flow characteristics of denture high-speed air turbine hand-piece unit was identified, in order to analyze the performance of the torque values were compared. In order to find out the difference of torque by mash values, under steady condition, performed grid convergence test. It compared theoretical torque with torque through flow analysis. To describe the motion of turbine blade was used to immerged solid method. Depending on the location of the turbine blade were calculated from five case. Maximum and minimum values of turbine blades was analyzed. To analyze the performance of the torque values were compared with speed of turbine blade.

  • PDF

160도 Contra angle을 갖는 소형 핸드피스용 1:2증속기어의 치형 해석 (Tooth Profile Analysis for Face Gear with 1:2 Gear Ratio in Handpiece with 160° Contra Angle)

  • 최지훈;안수경;박상신
    • Tribology and Lubricants
    • /
    • 제30권2호
    • /
    • pp.86-91
    • /
    • 2014
  • This paper presents a design procedure for a face gear and pinion used in a handpiece with a $160^{\circ}\acute{y}$ contra angle and 1:2 gear ratio. Based on the geometric theory of gearing, the tooth profile of the face gear and pinion is developed. To analyze the contact pressure, the gear profile should be determined before calculating the stress between the two gears. The concept of calculating the face gear profile is that it can be generated by the coordinate transformation of the shaper profiles, which have involute curves, using a simulation method from the gear manufacturing process.

치과용 시술기구(Micro Handpiece)재료의 특성평가 및 표면품질에 대한 연구 (Study on Evaluation of Material Property of Micro Handpiece for dentistry and Surface Quality)

  • 손재환;한창우;최상일;김용중;최창진
    • 한국산업융합학회 논문집
    • /
    • 제9권3호
    • /
    • pp.221-228
    • /
    • 2006
  • As Industrialization gets more and more advanced, human technological medical apparatus for dentistry has been developed. Such a medical apparatus have to let precision revolution and torque control facilitate. Consequently, Development of Micro hand-piece with strong durability should be required. Moreover, It's also very important to evaluate performance of such a Micro hand-piece, Evaluation of Mechanical property of Material and ANOVA have been known as useful methods in the field of Quality Evaluation. For Verification of Quality Evaluation, It has been evaluated by One-way layout ANOVA based on the data of Surface Roughness Test. Anyhow, This test has been respectively carried out by 3 kinds of Test and Superior performance has appeared in the Test result.

  • PDF

귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석 (Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model)

  • 모승한;강준구;김익환;최형준;송제선;신유석
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.62-69
    • /
    • 2020
  • 이 연구는 치과 핸드피스의 소음 수준과 소음 저감 장치의 효과를 평가하기 위한 것이다. 귀 모형은 치과용 핸드피스 작동 중에 내이에 전달되는 소음의 수준을 측정할 수 있도록 설계되었다. 소음의 크기는 귀 모형과 휴대용 소음 측정기를 사용하여 다양한 조건에서 측정되었다. 시판되는 4종의 소음 저감 장치를 귀 모형에 적용한 후 같은 조건에서 소음 수준을 측정한 뒤 비교하였다. 치과 핸드피스의 소음 수준은 조건에 따라 약 82.5 - 84.4 dB이었다. 4종의 소음 저감 장치를 적용했을 때 소음은 67.4 - 73.8 dB로 감소했다. 4종의 장치 모두 핸드피스의 소음을 줄이는데 유의한 효과가 있었다. 강도와 노출 시간을 고려할 때, 치과 소음은 치과 의료진에게 청력 손상을 일으킬 수 있다. 직업적 청력 손상 위험을 예방하기 위해 소음 저감 장치 사용을 고려할 수 있다.

두가지 피에조 엔진의 사용자 만족도 비교 (A comparative study on the user satisfaction between two different piezoelectric engines)

  • 임현미;이규복;이완선;최소영
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.269-277
    • /
    • 2017
  • 목적: 치과의사의 사용 만족도 비교를 통해 두 가지 피에조 엔진의 성능을 비교평가 하고자 한다. 연구 재료 및 방법: 본 연구에서는 두 가지의 피에조 엔진을 평가하였다:TRAUS XUS10 (Saeshin), PIEZOSURGERY touch (Mectron). 20명의 치과의사가 11개 평가항목에 답하였고, 평가결과는 Likert의 5점 척도를 적용하여 수치화하였다. 핸드피스 소음평가는 10초 동안 5회 측정하여 최고소음을 비교하였다. 핸드피스 발열평가는 세 부위에서 3분동안의 발열량을 측정하였다. 결과: 평가항목 중 '주수펌프 모터의 소음'에서 TRAUS XUS10이 PIEZOSURGERY touch보다 유의하게 만족도가 높았다. 반면, '기능key의 만족도'와 '핸드피스 발열정도'는 PIEZOSURGERY touch가 더 우수했다. 소음 최대값은 TRAUS XUS10이 56.6 dB, PIEZOSURGERY touch는 56.0 dB였다. 두 기기 모두 3분 작동 후 $41^{\circ}C$ 미만의 열을 발생시킴으로써 안전기준을 만족하였다. 결론: TRAUS XUS10는 '기능 key' 및 '핸드피스 발열정도'에서 약간의 개선을 한다면 그 외 대부분의 평가항목에서는 PIEZOSURGERY touch과 견줄만한 성능을 보인다.

치과용 핸드피스에 의한 일시적 진동감각역치 변화 (Temporary Threshold Shift of Vibration Sensation by Dental Handpiece)

  • 김성아;이종영;김두희;박순우
    • Journal of Preventive Medicine and Public Health
    • /
    • 제28권4호
    • /
    • pp.765-771
    • /
    • 1995
  • 치과용 핸드피스에서 발산하는 고주파수의 진동에 의한 일시적 진동감각역치 변화를 관찰하고자 치과위생병 28명을 대상으로 34,000rpm의 low-speed handpiece를 진동기구로 사용하였다. 진동에 폭로시키기 전과 후, 치과의사가 스케일링시 취하는 작업자세에 5분간 폭로시킨 후의 진동감각역치를 청력계기의 골전도진동기를 사용하여 250 Hz에서 그들이 주로 사용하는 손의 제2지두수에서 측정한 결과, 각각 $23.5{\pm}3.5dB,\;30.8{\pm}4.2dB,\;23.7{\pm}4.6dB$로 진동에 5분간 폭로시킨 후의 역치가 폭로 전에 비해 7.3dB의 유의한 증가가 있었다(p<0.001). 진동폭로 전후의 차이에 따른 분포를 보면, 10 dB 내외로 증가한 사람이 71.4%로 대부분이었고 16 dB의 증가가 가장 높았다. 진동 폭로 전의 진동감각역치와 신장, 체중, 체질량 지수와의 상관관계는 각각의 상관계수가 0.0360, -0.1657, -0.2641로 통계적 유의성은 없었으며, 흡연에 따른 차이도 흡연군(N=20)과 비흡연군(N=8)의 진동감 각역치가 각각 23.1 dB, 24.6 dB로 그 차이 가 없었다. 본 연구 결과로 볼 때 핸드피스와 같은 고주파-진동기구를 사용하는 치과의사 및 치과위생사에게서 진동감각역치의 변화가 예상되며, 말초신경병증의 원인이 될 수 있는 작업자세에 의한 장기간의 영향 및 아말감 충전시 사용하는 수은의 영향에 대해서도 연구가 필요할 것으로 생각된다.

  • PDF