• Title/Summary/Keyword: gamma correction

Search Result 198, Processing Time 0.023 seconds

Line Image Correction of the Positron Camera in the Secondary Beam Course of HIMAC

  • Iseki, Yasushi;Mizuno, Hideyuki;Kanai, Tatsuaki;Kanazawa, Mitsutaka;Kitagawa, Atsushi;Suda, Mitsuru;Tomitani, Takehiro;Urakabe, Eriko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.195-198
    • /
    • 2002
  • A positron camera, consisting of a pair of Anger-type scintillation detectors, has been developed for verifying the ranges of irradiation beams in heavy-ion radiotherapy. Images obtained by a centroid calculation of photomultiplier outputs exhibit a distortion near the edge of the crystal plane in an Anger-type scintillation detector. The images of a $\^$68/Ge line source were detected and look-up tables were prepared for the position correction parameters. Asymmetry of the position distribution detected by the positron camera was prevented with this correction. As a result, a linear position response and a position resolution of 8.6 mm were obtained over a wide measurement field.

  • PDF

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

An Recognition and Acquisition method of Distance Information in Direction Signs for Vehicle Location (차량의 위치 파악을 위한 도로안내표지판 인식과 거리정보 습득 방법)

  • Kim, Hyun-Tae;Jeong, Jin-Seong;Jang, Young-Min;Cho, Sang-Bock
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.1
    • /
    • pp.70-79
    • /
    • 2017
  • This study proposes a method to quickly and accurately acquire distance information on direction signs. The proposed method is composed of the recognition of the sign, pre-processing to facilitate the acquisition of the road sign distance, and the acquisition of the distance data. The road sign recognition uses color detection including gamma correction in order to mitigate various noise issues. In order to facilitate the acquisition of distance data, this study applied tilt correction using linear factors, and resolution correction using Fourier transform. To acquire the distance data, morphological operation was used to highlight the area, along with labeling and template matching. By acquiring the distance information on the direction sign through such a processes, the proposed system can be output the distance remaining to the next junction. As a result, when the proposed method is applied to system it can process the data in real-time using the fast calculation speed, average speed was shown to be 0.46 second per frame, with accuracy of 0.65 in similarity value.

Algorithms for Implementing One Chip Binary Image Processor (1칩 이진 영상 처리기 구현을 위한 알고리즘)

  • 조석팔;진용옥
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.3
    • /
    • pp.297-306
    • /
    • 1992
  • Algorithms for implementing one chip binary image processor has been studied. In this paper, image quality improvement algorithms, for the data pre-processed with shading and gamma correction after digitizing the analog signal from CCD or CIS, such as : Improved high quality binarization algorithm is suggested. Error diffusion algorithms for high quality half-tone images is analyzed, Fuzzy Theory based mixed mode algorithm is suggested.

  • PDF

Determination of Single Escape and Double Escape Peak Efficiency for a HPGe Detector

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.523-528
    • /
    • 2003
  • The efficiencies of single escape and double escape peaks were calculated by using Monte Carlo method and compared with measured efficiencies. The efficiency was obtained from the area ratio of escape peak to full energy absorption peak and the full energy absorption peak efficiency. For the escape peak interfered with other $\gamma-ray$ peaks, the net area was obtained by area correction. The GEANT code developed in CERN was used for the Monte Carlo calculation. The calculated efficiencies of the escape peaks agreed with the measurement within $12\%$.

A design of viterbi decoder for forward error correction (오류 정정을 위한 Viterbi 디코더 설계)

  • 박화세;김은원
    • The Journal of Information Technology
    • /
    • v.3 no.1
    • /
    • pp.29-36
    • /
    • 2000
  • Viterbi decoder is a maximum likelihood decoding method for convolution coding used in satellite and mobile communications. In this paper, a Viterbi decoder with constraint length of K=7, 3 bit soft decision and traceback depth of ${\Gamma}=96$ for convolution code is implemented using VHDL. The hardware size of designed decoder is reduced by 4 bit pre-traceback in the survivor memory.

  • PDF

Measurement of Branching Ratio for broad 27-keV Resonance of $^{19}F(n,g)^{20}F$ Reaction by using Time-of-flight Method with Anti-Compton NaI(Tl) Spectrometer

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.1
    • /
    • pp.31-34
    • /
    • 2008
  • The neutron capture spectrum for the light nuclide was very useful to study the nuclear structure. In the present study, the capture gamma-ray from the 27-keV resonance of $^{19}F(n,g)^{20}F$ reaction were measured with an anti-Compton NaI(Tl) spectrometer and the 3-MV Pelletron accelerator of the Research Laboratory for Nuclear Reactors at the Tokyo institute of technology. A neutron Time-of-Flight method was adopted with a 1.5 ns pulsed neutron source by the $^7Li(p,n)^7Be$ reaction. In the present experiment, a Teflon(($CF_2$)n) sample was used The sample was disk with a diameter of 90mm. The thickness of sample was determined so that reasonable counting rates could be obtained and the correction was not so large for the self-shielding and multiple scattering of neutrons in the sample, and was 5mm. The primary gamma-ray transitions were compared with previous measurement of Kenny.

  • PDF

Gray CCT Compensation Considered the White of Paper in Ink Jet Printer (Ink jet printer에서 paper의 white를 고려한 Gray CCT 보정)

  • 김대원;류동원;김희철;김은수;송규익
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.307-310
    • /
    • 2002
  • Color reproductions in most ink jet printer are quite different from that of standard CRT (cathode ray tube) monitor display because of the nonlinear characteristic in subtractive color reproduction. Gray scale CCT(correlated color temperature) reproductions in a typical printer are vary with the input RGB level. A simple method for making constant gray scale CCT and gamma value in photo paper is proposed in this paper. The compensation of the CCT with white point of the photo paper under the CIE standard illuminant D65 and color correction has been confirmed using the LUT(look-up table) to compensate the CCT and gamma curve characteristic.

  • PDF

Exposure Measurements of Co-60 Gamma rays (Co-60 감마선의 조사선량 측정)

  • Hah, Suck-Ho;Kim, Hyun-Moon
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.2
    • /
    • pp.7-16
    • /
    • 1991
  • Measurement of Co-60 gamma rays has been made for establishment of exposure standard and analyze it's overall uncertainties. Exposure rate determined by the charge mode method using vibrating reed amplifier with cylinderical type cavity chamber. The values of a variety of physical constants and the correction factors are evaluated. The resulting exposure rate is 690.81 R/h at the distance of 1m from the source and the related uncertainties is ${\pm}0.8%$

  • PDF

An upsampling Model Using Gaussian filter (가우시안 필터를 이용한 상향표본추출모델)

  • 박정윤;이상신;김상철;김중환
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10b
    • /
    • pp.520-522
    • /
    • 2000
  • 디지털영상을 상향표본추출(upsanpling)의 방법으로 확대하여 해상도를 높이는 경우에 확대한 영상은 확대 전의 영상에 비해 해상도는 높아지지만 흐려지거나 계단현상이 생기게 되어 영상의 품질은 저하된다. 본 연구에서는 확대된 영상에서 생기는 이와 같은 문제점을 보완하는 상향표본추출 모델을 제안한다. 제안된 모델은 8-이웃(8-neighborhood)과 가우시안 필터(Gaussian filter)를 이용하여 확대된 영상의 증가된 픽셀들의 픽셀값을 부여하여 확대 전 영상이 가진 특성이 확대 후에도 균질하게 유지될 수 있도록 하고 계단현상도 완화한다. 그리고 감마 교정(Gamma correction)을 이용하여 영상의 흐름 정도를 개선한다.

  • PDF