• 제목/요약/키워드: fire monitoring

검색결과 394건 처리시간 0.024초

The Great Western Woodlands TERN SuperSite: ecosystem monitoring infrastructure and key science learnings

  • Suzanne M Prober;Georg Wiehl;Carl R Gosper;Leslie Schultz;Helen Langley;Craig Macfarlane
    • Journal of Ecology and Environment
    • /
    • 제47권4호
    • /
    • pp.272-281
    • /
    • 2023
  • Ecosystem observatories are burgeoning globally in an endeavour to detect national and global scale trends in the state of biodiversity and ecosystems in an era of rapid environmental change. In this paper we highlight the additional importance of regional scale outcomes of such infrastructure, through an introduction to the Great Western Woodlands TERN (Terrestrial Ecosystem Research Network) SuperSite, and key findings from three gradient plot networks that are part of this infrastructure. The SuperSite was established in 2012 in the 160,000 km2 Great Western Woodlands region, in a collaboration involving 12 organisations. This region is globally significant for its largely intact, diverse landscapes, including the world's largest Mediterranean-climate woodlands and highly diverse sandplain shrublands. The dominant woodland eucalypts are fire-sensitive, requiring hundreds of years to regrow after fire. Old-growth woodlands are highly valued by Indigenous and non-Indigenous communities, and managing impacts of climate change and the increasing extent of intense fires are key regional management challenges. Like other TERN SuperSites, the Great Western Woodlands TERN SuperSite includes a core eddy-covariance flux tower measuring exchanges of carbon, water and energy between the vegetation and atmosphere, along with additional environmental and biodiversity monitoring around the tower. The broader SuperSite incorporates three gradient plot networks. Two of these represent aridity gradients, in sandplains and woodlands, informing regional climate adaptation and biodiversity management by characterising biodiversity turnover along spatial climate gradients and acting as sentinels for ecosystem change over time. For example, the sandplains transect has demonstrated extremely high spatial turnover rates in plant species, that challenge traditional approaches to biodiversity conservation. The third gradient plot network represents a 400-year fire-age gradient in Eucalyptus salubris woodlands. It has enabled characterisation of post-fire recovery of vegetation, birds and invertebrates over multi-century timeframes, and provided tools that are directly informing management to reduce stand-replacing fires in eucalypt woodlands. By building regional partnerships and applying globally or nationally consistent methodologies to regional scale questions, ecological observatories have the power not only to detect national and global scale trends in biodiversity and ecosystems, but to directly inform environmental decisions that are critical at regional scales.

영상복합형 해양플랜트 원격 관제 시스템 개발 (A development of video-complex remote monitoring system for offshore plant)

  • 김헌기;황훈규;유강주;이장세;박휴찬;신옥근;이성대
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.56-63
    • /
    • 2014
  • 해양플랜트는 태풍, 해일 등과 같은 환경적인 요소와 충돌, 화재 등의 인공적인 요소에 의해 위험에 노출되어 있기 때문에 일반적인 선박에 비해 유지보수 비용이 높으며 사고 발생 시, 빠른 대응이 어려워 관리적 측면에서 어려움이 많다. 이 논문에서는 이러한 문제를 개선하고 해양플랜트를 관제하기위해 AtoN AIS, 다단 데이터베이스를 활용한 영상복합형 해양플랜트 원격 관제 시스템을 개발한다. 개발한 시스템은 카메라 및 AIS를 이용하여 실시간으로 해양플랜트 주변의 영상 및 환경 정보를 수집하여 VHF 무선 통신 모뎀을 통해 전송하고, 육상에서 이를 수신하여 전자해도 기반의 원격 관제 어플리케이션을 통해 해양플랜트 주변의 상황을 정확하게 판단할 수 있게 해주며, 다단 데이터베이스를 이용하여 여러 정보를 효율적으로 관리할 수 있도록 해준다.

안드로이드 기반의 유증기 액화장치 모니터링 시스템 구현 (The implementation of liquefaction equipment monitoring system based on Android)

  • 박만규;탁한호;김관형
    • 한국정보통신학회논문지
    • /
    • 제20권3호
    • /
    • pp.583-589
    • /
    • 2016
  • VOCs(Volatile Organic Compounds)의 대부분은 유해물질로 대기 오염뿐만 아니라 지구 온난화의 원인물질로 작용하고 있다. 이로 인해 VOCs는 국가마다 배출을 줄이기 위해 정책적으로 관리되고 있다. 특히, 주유소에서 발생하는 유증기는 발암물질인 벤젠 등 인체에 유해하며 환경부에서 연료 주유 시 발생하는 휘발성 유기화합물을 회수할 수 있도록 유증기 회수장치 설치를 의무화하고 있다. 최근에는 기존의 유증기 처리 방식을 발전시켜 폭발이나 화재 등을 방지하기 위하여 유증기를 냉각시켜 현장에서 바로 회수하도록 하고 있다. 본 논문에서는 이러한 위험성이 존재하는 액화기의 상태를 실시간으로 모니터링 할 수 있도록 유증기 액화장치에 센서를 부착하여 액화기 측정 정보를 모니터링 할 수 있는 모니터링 서버 및 안드로이드 기반의 모니터링 앱 어플리케이션을 개발하여 원격관리 서비스 모델을 제시하고자 한다.

IoT 기반 열상 센서와 영상 센서 일체형 감시 장비 설계에 관한 연구 (A Study on the Design of IoT-based Thermal Sensor and Video Sensor Integrated Surveillance Equipment)

  • 이윤민;신진섭
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권6호
    • /
    • pp.9-13
    • /
    • 2019
  • 본 논문에서는 IoT 기반 열상 센서와 영상 센서 일체형 IP CCTV 설계에 관하여 연구하였으며 Full HD IP 카메라 영상과 열상모듈에서 전송되어지는 열상 데이터를 동시에 인지하여 가공 및 전송 할 수 있는 모니터링 시스템에 사용할 수 있도록 하였다. 열상 센서에서 감지하는 신호를 디지털로 변환하여 영상에 중첩시켜 실제 주변 온도에 대한 정보를 영상과 함께 실시간 제공하고, 영상 카메라에 열상이 추가됨으로 온도 변화를 예측하여 기존 장비에서 불가능한 화재 예측이 가능하게 하였다. 따라서 열상 센서와 영상센서 일체형 감시 장비를 통하여 환경 모니터링 시스템에서 전송되는 온도 데이터와 영상 신호를 송신하여 모니터링 시스템에 적용 가능하도록 하였다.

모바일 기기의 3차원 시각화와 증강현실에 기반한 센서네트워크 모니터링 프레임워크 (WIVA : WSN Monitoring Framework based on 3D Visualization and Augmented Reality in Mobile Devices)

  • 구본현;최효현;손태식
    • 전자공학회논문지CI
    • /
    • 제46권2호
    • /
    • pp.106-113
    • /
    • 2009
  • 최근 건설 현장에서의 많은 안전사고 발생으로 인해, 건축물의 건전성 감시(Structural Health Monitoring, SHM)에 대한 많은 연구가 진행되고 있다. 이러한 SHM의 활용을 위한 대표적인 적용 기술이 무선 센서네트워크 기술(Wireless Sensor Networks, WSN)이다. 본 논문에서는 이러한 무선 센서네트워크 기술을 바탕으로 카메라가 장착된 휴대단말기에 3D 시각화와 증강현실(Augmented Reality, AR) 기술을 적용한 관찰 가능한 정보의 범위를 확장시켜주는 WIVA(WSN Monitoring Framework based on 3D Visualization and Augmented Reality in Mobile Devices) 시각화 시스템을 제안하였다. 제안된 시스템을 이용해 3층 건물 테스트베드에서의 화재 발생 실험을 수행하였다. 이를 통해, IEEE 802.15.4를 이용한 WSN 데이터를 활용한 3D와 AR 모드에서의 효용성을 검증하였다.

보일러 내부 고온가스에 노출된 전열 튜브에서의 열유속 평가 방법 (Estimation method of heat flux at tube bank exposed to high temperature flue gas in large scale coal fired boilers)

  • 정재진;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.259-264
    • /
    • 2009
  • Most of the fossil power plants firing lower grade coals are challenged with maintaining good combustion conditions while maximizing generation and minimizing emissions. In many cases significant derate, availability losses and increase in unburned carbon levels can be attributed to poor combustion conditions as a result of poorly controlled local fuel and air distribution within the boiler furnace. The poor combustion conditions are directly related to the gas flow deviation in upper furnace and convection tube-bank but a less reported issue related to in large-scale oppose wall fired boilers. In order to develop a on-line combustion monitoring system and suggest an alternative heat flux estimation method at tube bank, which is very useful information for boiler design tool and blower optimizing system, field test was conducted at operating power boiler. During the field test the exhaust gases' temperature and tube metal temperature were monitored by using a spatially distributed sensors grid which located in the boiler's high temperature vestibule region. At these locations. the flue gas flow is still significantly stratified, and air in-leakage is minimal which enables tracing of poor combustion zones to specific burners and over-fire air ports. Test results showed that the flue gas monitoring method is more proper than metal temperature distribution monitoring for real time combustion monitoring because tube metal temp. distribution monitoring method is related to so many variables such as flue gas, internal flow unbalance, spray etc., Heat flux estimation at the tube bank with flue gas temp. and metal temp. data can be alternative method when tube drilling type sensor can't able to use.

  • PDF

방전신호 검출에 의한 히팅 케이블의 상태감시기술 (Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal)

  • 김동언;김남훈;임승현;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제34권2호
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

원격탐사와 GIS를 이용한 재난 예측, 감시 및 대응 (Disaster Prediction, Monitoring, and Response Using Remote Sensing and GIS)

  • 김준우;김덕진;손홍규;최진무;임정호
    • 대한원격탐사학회지
    • /
    • 제38권5_2호
    • /
    • pp.661-667
    • /
    • 2022
  • 원격탐사와 GIS를 활용한 공간자료 분석은 재난 관리에 효율적인 기술로 이를 활용한 재난정보 제공을 위한 자료 분석 및 기술 개발에 관한 연구가 활발히 진행되고 있다. 특히 군집위성의 발사와 다양한 원격탐사 플랫폼의 활용, 취득된 데이터 처리 및 저장 능력의 향상, 인공지능 기술의 발달 등으로 인해 재난 관리를 위한 원격탐사와 GIS 기술의 활용은 많은 발전의 여지를 가지고 있다. 이번 특별호에는 재난의 예측, 감시 그리고 대응 단계에서 선박탐지, 건축물 추출, 해양환경 감시, 홍수탐지, 산불탐지, 그리고 재난 발생시 의사결정지원에 적용 가능한 원격탐사와 GIS 기술의 개발과 활용한 관련한 10편의 논문이 게재되었다. 이번 특별호에 출판된 논문들은 재난 관리 기술의 발전과 연관 학문 분야의 학술적 발전에 밑거름이 될 것으로 판단된다.

IoT를 활용한 흔들림 방지 버팀대의 내진설계에 관한 연구 (A Study on the Seismic Resistance Design of Sway Brace Device using Internet of Things)

  • 탁성인;유봉근;손봉세
    • 한국화재소방학회논문지
    • /
    • 제31권1호
    • /
    • pp.58-62
    • /
    • 2017
  • 국내에서도 내진설계의 필요성이 점차 증대되고 있다. 그 중에서도 비구조요소인 소화배관의 흔들림 방지 버팀대에 관한 연구가 계속되고 있다. 이에 본 연구에서는 흔들림 방지 버팀대의 하중 시험을 통하여 유효한 범위를 측정하였다. 그 결과, 하중 0에서부터 18.5 kN까지 설계안전 범위로 측정되었으며 최대 29.4 kN에서도 흔들림 방지 버팀대의 구조 및 성능에 이상 없이 정상 작동하였다. 또한 사물인터넷의 환경을 이용하여 센서노드로부터 데이터를 전송받아 유효 하중범위 안에서 추출과 예측단계를 거쳐 재난정보를 수신케 하는 모니터링 시스템의 모듈을 구성하였다.

농촌 소나무림에서 산불에 의한 식생변화와 유용미생물의 적용 (Vegetation Change after A Forest Fire in a Rural Japanese Red Pine Forest and Applications of Effective Microorganism)

  • 여지선;김기대
    • 한국환경복원기술학회지
    • /
    • 제11권4호
    • /
    • pp.46-56
    • /
    • 2008
  • This study examined the natural restoration of vegetation through monitoring of the development of a vegetation community from 2006 through 2007 after a forest fire. Approximately 5,000 $m^2$ in a forest near Topyeon-ri, Kangnae-myeon, Chungcheongbuk-do with Japanese red pine (Pinus densiflora) forest and its floor vegetation had been completely burned by a fire in April 2005. This area and another nearby Japanese red pine forest were selected as the experiment site and the control site, respectively. Vegetation survey was conducted at the experiment site and the control site. A seed bank experiment was carried out in the greenhouse to examine underground vegetation. Effective microorganism(EM) was applied to the seed bank experiment to estimate its effects on the direction of ecological succession. According to the results, a total of 36 plant species including shrub and herbaceous species were discovered in the experiment site. Quercus serrata, Lespedeza cyrtobotrya, and Castanea crenata, Rubus crataegifolius, Oplismenus undulatifolius, and Carex lanceolata were among the most abundant species. Biomass in the experiment site reached 2.4 times biomass than those in the control site, indicating the productivities of shrub and herbaceous layers are better in the experiment site. According to the result of the soil seed bank experiment of the experiment site, a total of 182 plants of 14 species were recorded. In addition, a total of 13 plants of 2 species were found from soil seed bank of the experiment site applied by EM. If EM is applied to the burned site, it will control the budding of herbaceous plants, creating the gap between herbaceous plants. This loss of competition is expected to help the restoration of trees in the burned area.