• Title/Summary/Keyword: filling disc

Search Result 20, Processing Time 0.023 seconds

Cu Via-Filling Characteristics with Rotating-Speed Variation of the Rotating Disc Electrode for Chip-stack-package Applications (칩 스택 패키지에 적용을 위한 Rotating Disc Electrode의 회전속도에 따른 Cu Via Filling 특성 분석)

  • Lee, Kwang-Yong;Oh, Tae-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.3
    • /
    • pp.65-71
    • /
    • 2007
  • For chip-stack package applications, Cu filling characteristics into trench vias of $75{\sim}10\;{\mu}m$ width and 3 mm length were investigated with variations of the electroplating current density and the speed of a rotating disc electrode (RDE). Cu filling characteristics into trench vias were improved with increasing the RDE speed. There was a Nernst relationship between half width of trench vias of Cu filling ratio higher than 95% and the minimum RDE speed, and the half width of trenches with 95% Cu filling ratio was linearly proportional to the reciprocal of root of the minimum RED speed.

  • PDF

Design and Fabrication of Durable Micro Heater for Intelligent Mold System (금형온도 능동제어 시스템 적용을 위한 고 내구성 마이크로 히터의 설계 및 제작)

  • Noh Cheolyong;Kim Youngmin;Choi Yong;Kang Shinill
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.26-30
    • /
    • 2005
  • Stamper surface temperature is very critical in replicating the high density optical disc substrates using injection molding as the pit or land/groove patterns on the optical disc substrate have decreased due to the rapid increase of areal density. During the filling stage, the polymer melt in the vicinity of the stamper surfaces rapidly solidifies and the solidified layer generated during polymer filling greatly deteriorates transcribability and fluidity of polymer melt. To improve transcribability and fluidity of polymer melt, stamper surface temperature should be controlled such that the growth of the solidified layer is delayed during the filling stage. In this study, the effect of heating on replication process was simulated numerically. Then, an injection mold equipped with instant active heating system was designed and constructed to raise the stamper surface temperature over the glass transition temperature during filling stage of the injection molding. Also, the closed loop controller using the Kalman filter and the linear quadratic Gaussian regulator was designed. As a result, the stamper surface temperature was controlled according to the desired reference stamper surface temperature.

  • PDF

Design and Fabrication of Durable Micro Heater for Intelligent Mold System (금형온도 능동제어 시스템 적용을 위한 고 내구성 마이크로 히터의 설계 및 제작)

  • Noh, Cheol-Yong;Kim, Young-Min;Choi, Yong;Kang, Shin-Ill
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.100-104
    • /
    • 2006
  • Stamper surface temperature is very critical in replicating the high density optical disc substrates using injection molding as the pit or land/groove patterns on the optical disc substrate have decreased due to the rapid increase of areal density. During the filling stage, the polymer melt in the vicinity of the stamper surfaces rapidly solidifies and the solidified layer generated during polymer filling greatly deteriorates transcribability and fluidity of polymer melt. To improve transcribability and fluidity of polymer melt, stamper surface temperature should be controlled such that the growth of the solidified layer is delayed during the filling stage. In this study, the effect of heating on replication process was simulated numerically. Then, an injection mold equipped with instant active heating system was designed and constructed to raise the stamper surface temperature over the glass transition temperature during filling stage of the injection molding. Also, the closed loop controller using the Kalman filter and the linear quadratic Gaussian regulator was designed. As a result. the stamper surface temperature was controlled according to the desired reference stamper surface temperature.

  • PDF

ON FILLING DISCS IN THE STRONG BOREL DIRECTION OF ALGEBROID FUNCTION WITH FINITE ORDER

  • Huo, Yingying;Kong, Yinying
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.6
    • /
    • pp.1213-1224
    • /
    • 2010
  • Using Ahlfors' covering surface method, some properties on the strong Borel direction of algebroid function of finite order are obtained. The main object of this paper is to prove existence theorem of a strong Borel direction and the existence of filling discs in such direction which briefly extends some results of meromorphic function.

AN EXPERIMENTAL STUDY ON THE EFFECT OF COMPOSITE RESIN AND BACTERIA TO PULP RESPONSE (복합(複合)레진과 세균(細菌)이 치수반응(齒髓反應)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Cho, Sung-Sik;Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.53-67
    • /
    • 1988
  • An investigation was carried out to compare the pulp responses against a few type of composite and streptococcus mutans contamination under the zinc oxide eugenol cement, and also confirmed pulpal responses of various composites with or without base. Seventy eight teeth from 6 dogs were employed and divided into 6 groups. Class V cavities were prepared on each tooth routinely with low speed dental engine. Paper disc about 0.3mm thick was immersed in the BHI broth in which streptococcus mutans had been enriched and the disc was inserted on the cavity floor prior to filling. Scotch bond puls Silux as Bis-GMA system composite resin and Helimolar as urethane system composite resin were adopted. Control group: Zinc-Oxide Eugenol cement filling Experimental groups: Group 1. Scotch bond + Silux filling with Dycal base Group 2. Heliomolar filling with Dycal base Group 3. Scotch bond + Silux filling without base Group 4. Heliomolar filling without base Group 5. Streptococcus mutans application. All cavities were sealed with thick ZOE cement to avoid marginal leakage. Postoperative intervals of 1, 2, 3, 4, 5 and 6 weeks teeth were carefully extracted, processed and stained with Hematoxylin and Eosin. The results were as follows: 1. S. mutans application group and composites without any base showed more severe pupal response than control group and dyca based groups. 2. The experimental group of S. mutans application showed severe response in the early stage compared to the two groups of composite resin without base, but no significant difference was found following periods. 3. The difference of pulpal response is not significant between Bis-GMA system and urethane system. 4. Streptococcus mutans application group and composites without base groups showed the evidence of histologic recovery at the six week cases and the large amount of reparative dentin was the prominent feature. 5. Pulp responses against every material were inclined to normal according to the time elapsed.

  • PDF

POLYMERIZATION SHRINKAGE, HYGROSCOPIC EXPANSION AND MICROLEAKAGE OF RESIN-BASED TEMPORARY FILLING MATERIALS (레진계 임시수복재의 중합수축, 수화팽창과 미세누출)

  • Cho, Nak-Yeon;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to measure the polymerization shrinkage and hygroscopic expansion of resin-based temporary filling materials and to evaluate microleakage at the interface between the materials and cavity wall. Five resin-based temporary filing materials were investigated: Fermit (Vivadent), Quicks (Dentkist), Provifil (Promedica), Spacer (Vericom), Clip (Voco). Caviton (GC) was also included for comparison. Polymerization shrinkage of five resin-based temporary filling materials was measured using the bonded disc method. For the measurement of hygroscopic expansion, the discs of six cured temporary filling materials were immersed in saline and a LVDT displacement sensor was used to measure the expansion for 7 days. For estimating of microleakage, Class I cavities were prepared on 120 extracted human molars and randomly assigned to 6 groups of 20 each. The cavities in each group were filled with six temporary filling materials. All specimens were submitted to 1000 thermocycles, with temperature varying from $5^{\circ}C/55^{\circ}C$. Microleakage was determined using a dye penetration test. The results were as follows: 1. Fermit had significantly less polymerization shrinkage than the other resin-based temporary fill ing materials. Fermit (0.22%) < Spacer (0.38%) < Quicks (0.64%), Provifil (0.67%), Clip (0.67%) 2. Resin-based temporary filling materials showed 0.43-1.1% expansion in 7 days. 3. Fermit showed the greatest leakage, while Quicks exhibited the least leakage. 4. There are no correlation between polymerization shrinkage or hygroscopic expansion and microleakage of resin-based temporary filling materials.

Investigation on the effect of eccentricity for fuel disc irradiation tests

  • Scolaro, A.;Van Uffelen, P.;Fiorina, C.;Schubert, A.;Clifford, I.;Pautz, A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.5
    • /
    • pp.1602-1611
    • /
    • 2021
  • A varying degree of eccentricity always exists in the initial configuration of a nuclear fuel rod. Its impact on traditional LWR fuel is limited as the radial gap closes relatively early during irradiation. However, the effect of misalignment is expected to be more relevant in rods with highly conductive fuels, large initial gaps and low conductivity filling gases. In this paper, we study similar characteristics in the experimental setup of two fuel disc irradiation campaigns carried out in the OECD Halden Boiling Water Reactor. Using the multi-dimensional fuel performance code OFFBEAT, we combine 2-D axisymmetric and 3-D simulations to investigate the effect of eccentricity on the fuel temperature distribution. At the same time, we illustrate how the advent of modern tools with multi-dimensional capabilities might further improve the design and interpretation of in-pile separate-effect tests and we outline the potential of such an analysis for upcoming experiments.

A STUDY ON SURFACE ROUGHNESS OF COMPOSITE RESINS AFTER FINISHING AND POLISHING -an Atomic Force Microscope study (연마방법에 따른 복합레진의 활택도에 관한 연군 -Atomic Force Microscope를 이용한 연구)

  • Kim, Hyeong-Seob;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.719-741
    • /
    • 1997
  • This study was undertaken to compare by Atomic Force Microscope the effects of various finishing and polishing instruments on surface roughness of filling and veneering composite resins. Seven composite resins were studied : Silux Plus (3M Dental Products, U.S.A.), Charisma (Heraeus Kulzer, Germany), Prisma THP (L.D.Caulk, Dentsply, U.S.A.), Photoclearfil (Kuraray, Japan), Cesead (Kuraray, Japan), Thermoresin LC (GC, Japan), Artglass (Heraeus Kulzer, Germany). Samples were placed and polymerized in holes (2mm thick and 8.5mm in diameter) machined in Teflon mold under glass plate, ensuring excess of material and moulded to shape with polyester matrix strip. Except control group (Polyester matrix strip), all experimental groups were finished and polishied under manufacturer's instructions. The finishing and polishing procedure were : carbide bur (E.T carbide set 4159, Komet, Germany), diamond bur (composite resin polishing bur set, GC, Japan), aluminum-oxide disc (Sof-Lex Pop-On, 3M Dental Products, U.S.A.), diamond-particle disc (Dia-Finish, Renfert Germany), white stone bur & rubber point( composite finishing kit, EDENTA, Swiss), respectively. Each specimens were evaluated for the surface roughness with Atomic Force Microscope (AutoProbe CP, Park Scientific Instruments, U.S.A.) under contact mode and constant height mode. The results as follows : 1. Except Thermoresin LC, all experimental composite resin groups showed more rougher than control group after finishing and polishing(p<0.1). 2. A surface as smooth as control group was obtained by $Al_{2}O_{3}$ disc all filling composite resin groups except Charisma and all veneering composite resin groups except Thermoresin LC(p<0.05). 3. In case of Thermoresin LC, there were no statistically significant differences before and after finishing and polishing(p>0.1). 4. Carbide bur, diamond bur showed rough surfaces in all composite resin groups, so these were inappropriate for the final polishing instruments.

  • PDF

Beam Pattern Optimization of Hexagonal Array Transducer Using Finite Element Method (유한 요소기법에 의한 육각형 배열 변환기의 지향성 최적화)

  • 장순석;이제형;안흥구
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.123-128
    • /
    • 2000
  • This paper describes the optimization of the hexagonal array transducer using finite element method. The transducer consists of the disc type sensors. Three dimensional beam patterns of each element and the array transducer are analysed using the finite element code ATILA. Beam patterns were analyzed for the disc type transducer. To optimize beam patterns of the array transducer, Chebyshev polynomial weight is applied to each element. In case of applying optimized weight, a 30 degree width beam pattern is presented at 10kHz. This paper also includes the effect of rubber filling material instead of using the water inside the transducer array.

  • PDF

Study on shear fracture behavior of soft filling in concrete specimens: Experimental tests and numerical simulation

  • Lei, Zhou;Vahab, Sarfarazi;Hadi, Haeri;Amir Aslan, Naderi;Mohammad Fatehi, Marji;Fei, Wu
    • Structural Engineering and Mechanics
    • /
    • v.85 no.3
    • /
    • pp.337-351
    • /
    • 2023
  • In this paper, the shear behavior of soft filling in rectangular-hollow concrete specimens was simulated using the 2D particle flow code (PFC2D). The laboratory-measured properties were used to calibrate some PFC2D micro-properties for modeling the behavior of geo-materials. The dimensions of prepared and modeled samples were 100 mm×100 mm. Some disc type narrow bands were removed from the central part of the model and different lengths of bridge areas (i.e., the distance between internal tips of two joints) with lengths of 30 mm, 50 mm, and 70 mm were produced. Then, the middle of the rectangular hollow was filled with cement material. Three filling sizes with dimensions of 5 mm×5 mm, 10 mm×5 mm, and 15 mm×5 mm were provided for different modeled samples. The parallel bond model was used to calibrate and re-produce these modeled specimens. Therefore, totally, 9 different types of samples were designed for the shear tests in PFC2D. The shear load was gradually applied to the model under a constant loading condition of 3 MPa (σc/3). The loading was continued till shear failure occur in the modeled concrete specimens. It has been shown that both tensile and shear cracks may occur in the fillings. The shear cracks mainly initiated from the crack (joint) tips and coalesced with another one. The shear displacements and shear strengths were both increased as the filling dimensions increased (for the case of a bridge area with a particular fixed length).