• 제목/요약/키워드: fiber mixed concrete

검색결과 166건 처리시간 0.041초

바잘트 섬유 및 하이볼륨 플라이애시를 사용한 모르타르의 유동특성에 관한 실험적 연구 (The Experimental Study on the Fluidity Properties of Mortar Using Basalt Fiber and High Volume Fly Ash)

  • 최연왕;오성록;박만석;최병걸
    • 한국건설순환자원학회논문집
    • /
    • 제2권4호
    • /
    • pp.345-353
    • /
    • 2014
  • This study was evaluated influence of fluidity properties according to basalt fiber and high volume fly ash in the mortar level, as part of a basic study for development of fiber reinforced concrete using basalt fiber and high volume fly ash. In the first step, it was evaluated that fluidity properties of mortar according to replacement ratio 6 level of fly ash(10, 20, 30, 40, 50 and 60mass%) and fluidity properties of mortar according to content 5 levels of SP(1.3, 1.5, 1.7, 1.9 and 2.1%) and content 5 levels of VA(0.2, 0.4, 0.6, 0.8 and 1.0%) for dispersion of the basalt fiber, in the second step, it was evaluated that fluidity properties of mortar using High-volume fly ash (50mass%) on 3 levels of basalt fiber length (6, 20 and 30mm). Results of assessment, if after a fiber mixed, it showed that viscosity agent is more effective to improve the fluidity and fiber dispersion than superplasticizer, high volume fly ash (50%) applying the mixing, due to three properties of fly ash, showed that the improved fiber dispersibility and flow improvement.

방수보호재 및 방근재로서의 활용을 위한 토목용 보강섬유의 실험적 연구 (Experimental Study on Reinforcing Fiber for Civil Engineering used for Waterproofing Protection and Root Resistance Performance)

  • 김범수;이정훈;송제영;송영찬;김용로;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.67-68
    • /
    • 2017
  • This paper discusses the application of civil structure use reinforcing fiber mixed with concrete to be used as protection layer of waterproofing material and root resistant layer installed in below-grade parking lot upper slab of residential building. A performance evaluation under the prescribed method outlined in KS F 4938 was used for this new material. The testing results showed that the fiber reinforcement can be used to strengthen the protection for the waterproofing material. Also, plants that were planted in June 2016 have not yet penetrated the specimens used for root resistance testing. The domestic root resistance performance testing usually covers the period of 2 years, thus further observation to make any conclusion about the root resistance property is required.

  • PDF

터널 내화용 고강도 습식 스프레이 폴리머 모르타르의 화재 발생시 내부온도분포 (Temperature Distribution of Wet-Mixed High Strength Sprayed Polymer Mortar for Fire Resistance of Tunnel)

  • 원종필;최석원;박찬기;박해균
    • 대한토목학회논문집
    • /
    • 제26권4C호
    • /
    • pp.283-290
    • /
    • 2006
  • 콘크리트는 열전도열이 작은 불연성의 재료이다. 그렇지만 콘크리트는 화재에 저항하도록 설계되지 않으면 열을 받을시 공극압과 내부인장응력이 발생하여 폭렬이 발생한다. 본 연구에서는 터널 내화용 습식 고강도 스프레이 폴리머 모르타르의 성능을 실험적 및 수치해석적으로 평가하였다. 이를 위하여 화재시험을 수행하였다. 시험은 RABT 온도가열곡선을 이용하여 내화로에서 수행하였으며, 터널 내화용 습식 스프레이 모르타르의 피복두께에 따른 온도분포를 평가하였다. 실험 및 수치해석적 분석 결과를 기본으로 하여 터널 내화용 습식 고강도 스프레이 폴리머 모르타르의 적정 피복두께는 4cm이상으로 결정하였다.

Experimental and numerical studies of concrete bridge decks using ultra high-performance concrete and reinforced concrete

  • Shemirani, Alireza Bagher
    • Computers and Concrete
    • /
    • 제29권 6호
    • /
    • pp.407-418
    • /
    • 2022
  • This paper numerically investigates the effect of changes in the mechanical properties (displacement, strain, and stress) of the ultra-high-performance concrete (UHPC) without rebar and the reinforced concrete (RC) using steel re-bars. This reinforced concrete is mostly used in the concrete bridge decks. A mixture of sand, gravel, cement, water, steel fiber, superplasticizer, and micro silica was used to fabricate UHPC specimens. The extended finite element method as used in the ABAQUS software is applied for considering the mechanical properties of UHPC, RC, and ordinary concrete specimens. To calibrate the ABAQUS, some experimental tests have been carried out in the laboratory to measure the direct tensile strength of UHPC by the compressive-to-tensile load converting (CTLC) device. This device contains a concrete specimen and is mounted on a universal tensile testing apparatus. In the experiments, three types of mixed concrete were used for UHPC specimens. The tensile strength of these specimens ranges from 9.24 to 11.4 MPa, which is relatively high compared with ordinary concrete specimens, which have a tensile strength ranging from 2 to 5 MPa. In the experimental tests, the UHPC specimen of size 150×60×190 mm with a central hole of 75 mm (in diameter)×60 mm (in thickness) was specially made in the laboratory, and its direct tensile strength was measured by the CTLC device. However, the numerical simulation results for the tensile strength and failure mechanism of the UHPC were very close to those measured experimentally. From comparing the numerical and experimental results obtained in this study, it has been concluded that UHPC can be effectively used for bridge decks.

경량골재와 팽창펄라이트를 활용한 경량 시멘트복합체의 특성 (Quality Characteristics of Lightweight Cement Composite using Lightweight Aggregates and Expanded Perlite)

  • 김득모;문경주;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.533-536
    • /
    • 2004
  • This study aims to manufacture and to evaluate lightweight cement composite using lightweight aggregate and expanded perlite. The expanded perlite and lightweight aggregates were mixed with cement, water, SP(superplasticizer), forming-agent and poly-propylene fiber. The specimens were cured at $20^{\circ}C$ for 24h and then at steam curing of $60^{\circ}C$, RH $100\%$ for 12h. As a result, We could make lightweight cement composite of satisfaction about ALC properties. However it is need to improve the properties of density and water absorption.

  • PDF

강섬유와 묶음철근 보강을 통한 고성능 연결보의 이력거동 평가 (Hysteretic Behavior Evaluation of a RC Coupling Beam using a Steel Fiber and Diagonal Reinforcement)

  • 오해철;이기학;한상환;신명수;조영욱
    • 콘크리트학회논문집
    • /
    • 제27권3호
    • /
    • pp.291-298
    • /
    • 2015
  • 본 논문은 시공성과 내진성능을 증대하기 위해 고성능 강섬유를 혼합한 묶음대각철근 연결보를 제시한다. 연결보의 실험은 4개의 실험체로 구성하고 고성능 강섬유를 혼합한 실험체에 반복하중을 가하여 이력거동을 비교 평가하였다. 실험의 주요 변수는 강섬유의 혼합에 따라 대각철근의 묶음 여부와 스터럽의 철근량이다. 기준이 되는 실험체는 묶음대각철근에 ACI318에서 요구하는 스터럽의 철근량을 100% 적용하였다. 이와 함께, 동일한 묶음대각철근을 적용한 상태에서 스터럽의 철근량을 75%와 50%로 조절하여 두 실험체를 추가적으로 만들고 일반대각철근을 고려, 총 4개의 실험체가 제작되었다. 이번 실험에서 연결보의 콘크리트 타설시 고성능 강섬유를 함유율 1%로 혼합하였다. 모든 실험체는 1/2스케일로 형상비 3.5(l/h=1050/300)으로 이루어졌다. 본 실험결과에서 강섬유를 1% 혼입한 고성능 시멘트를 적용한 연결보는 스터럽 철근양을 75%, 50% 줄인 것과 기준실험체로 적용된 스터럽 철근양 100%의 강도 및 강성, 에너지소산능력에서 큰 차이를 보이지 않았다.

세그먼트 라이닝의 PP섬유 혼입량과 공기량 변화에 따른 화재저항 특성 평가 (Evaluation of Segment Lining Fire Resistance Based on PP Fiber Dosage and Air Contents)

  • 최순욱;강태성
    • 터널과지하공간
    • /
    • 제31권6호
    • /
    • pp.469-479
    • /
    • 2021
  • 콘크리트의 폭렬방지 재료로서 PP섬유는 그 효과가 이미 확인되었다. 그러나 화재 시 발생하는 최대온도에 대한 고려가 필요하고 배합량에 따라 발생하는 믹싱문제 및 강도저하 문제의 해결이 필요하다. 본 연구에서는 RABT화재시나리오 하에서 PP섬유 함유량과 공기량에 따른 터널 세그먼트 라이닝의 화재저항성능을 살펴보았다. 그 결과, 모든 시험체에서 폭렬과 단면손실은 발생하지 않았으며, PP섬유 함유량이 작을 경우 상대적으로 최대온도가 높고 최대온도 도달시간 역시 빠른 것으로 나타났다. 반면, 공기량 차이에 따른 최대온도와 도달시간에 대한 어떤 경향을 발견하지 못했다. PP섬유 혼입량 0.75, 1.0, 1.5, 2.0 kg/m3인 경우에 대한 시험체 내부 온도분포 결과에서는 0.75와 1.0 kg/m3의 결과가 유사한 온도분포를 보였으며, 1.5와 2.0 kg/m3의 결과가 유사하게 나타났다. PP섬유 혼입량이 많을 경우 동일 깊이에서 내부 온도분포가 낮아지는 경향이 있는 것을 확인할 수 있었으며, PP섬유 혼입량 1.0 kg/m3와 1.5kg/m3의 결과에서 주목할 만한 차이가 발생함을 확인하였다.

오버레이용 투수성 콘크리트의 개발에 관한 연구 (A Study on the Development of Water-Permeable Concretes for Overlay)

  • 은재기;김완기;조영국;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.223-226
    • /
    • 1999
  • The purpose of this study is no examine the combination effect on strength preperties of water-permeable concretes mixed with redispersible polymer, silica fume and polypropylene fibers for overlay in pavement. The water-permeable concrete with a water-cement ration of 25%, polymer-cement ratios of 0 to 10%, silica fume contents of 0 to 10% and polypropylene fiver contents of 0 to 1.5% are prepared, and tested for flexural strength, compressive strength and water permeability. It is concluded concretes are obtained at a polypropylene fiber content of 1.0% and a silica fume content of 10% with a void filling ratio of 50%. And the water-permeable concretes with a flexural strength of 14.1~28.0kgf/$\textrm{cm}^2$, a compressive strength of 71.2~128.0kgf/$\textrm{cm}^2$, and a coefficient of permeability of 1.22~2.52cm/s at a void filling ratio of 30% can be prepared. Also water-permeable concretes having flexural strength of 24.9~57.9kgf/$\textrm{cm}^2$, a compressive strength of 83.8~268.5kgf/$\textrm{cm}^2$, and a coefficient of permeability of 0.24~1.04cm/s at a void filling ratio of 50% can be prepared in the consideration of the mix proportioning factors.

  • PDF

섬유의 보강 형태에 따른 섬유-시멘트 혼합토의 일축압축강도특성 (Unconfined Compressive Strength of Fiber-reinforced Cemented Sands by Fiber Reinforcement Form)

  • 박성식;김영수;이종천
    • 한국지반공학회논문집
    • /
    • 제23권8호
    • /
    • pp.159-169
    • /
    • 2007
  • 취성적인 파괴를 보이는 시멘트 혼합토의 역학적 특성을 개선하기 위하여 단섬유를 사용한 섬유시멘트 혼합토에 관한 연구를 수행하였다. 낙동강 유역에서 채취한 모래, 보통포틀랜드시멘트 그리고 최근 콘크리트와 시멘트 보강재로 많이 사용되고 있는 폴리비닐알코올(PVA) 섬유를 사용하였다. PVA 섬유는 시멘트와 접착성이 매우 우수하며 비중이 1.3으로 물보다 약간 큰 것이 특징이며 시멘트 보강재로 사용되고 있는 일반 PVA 섬유보다는 다소 직경이 큰 0.1mm의 PVA 섬유를 사용하였다. 깨끗한 낙동강 모래에 시멘트와 섬유를 최적함수비로 잘 섞은 후 5층으로 나누어 층당 55회 다짐하여 공시체를 만든 후 7일간 양생시켰다. 모든 공시체의 시멘트 혼합율은 4%로 동일하지만 섬유의 혼합위치를 다르게 시료를 제작하여 일축압축시험을 실시하였다. 강도시험에서 섬유의 보강 형태와 위치에 따른 일축압축강도의 특성을 비교하였으며, 동일한 양의 섬유가 균일하게 보강된 경우의 일축압축강도가 그렇지 않은 경우보다 약 2배 증가하였다. 층당 섬유 혼합율이 동일할 경우 섬유 보강율이 증가함에 따라 일축압축강도도 증가하였으며, 전층이 보강되었을 때의 일축압축강도는 중간층만 보강된 경우보다 1.5배 이상 강도가 증가하였다. 섬유-시멘트 혼합토 거동에서 섬유의 혼합율과 섬유가 골고루 잘 분산되도록 하는 방법 또는 분산이 용이한 섬유를 선택하는 것이 중요하였다.

복합섬유가 혼입된 고강도 콘크리트의 고온가열에 따른 성능 평가 (Performance Evaluation of High Strength Concrete with Composite Fibers in Accordance with High Temperature)

  • 김승기;김우석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권6호
    • /
    • pp.63-71
    • /
    • 2015
  • 본 연구는 섬유를 혼입한 고강도 콘크리트의 온도 변화에 따른 내화특성 분석에 관한 연구로 고강도 콘크리트에 고온이 가해질 경우 발생되는 폭렬현상에 대하여 방지효과가 있는 것으로 알려져 있는 하이브리드섬유와 강섬유를 함께 혼입하여 만든 복합섬유를 사용하여 온도 변화($100{\sim}800^{\circ}C$)에 따른 고강도 콘크리트의 내화특성 및 역학적 메커니즘을 분석하였다. 또한 본 논문에서는 고강도 콘크리트 구조물에서 가장 문제가 되는 폭렬현상을 막는 대책 중의 하나인 섬유 혼입을 통한 방법을 사용하여 SEM 및 XRD 분석 등의 방법으로 고온을 받은 고강도 콘크리트의 열적 특성 및 역학적 특성을 규명하고자 하였다.