Performance Evaluation of High Strength Concrete with Composite Fibers in Accordance with High Temperature

복합섬유가 혼입된 고강도 콘크리트의 고온가열에 따른 성능 평가

  • 김승기 (금오공과대학교 일반대학원 건축공학과) ;
  • 김우석 (금오공과대학교 건축학부)
  • Received : 2015.05.22
  • Accepted : 2015.09.21
  • Published : 2015.11.01

Abstract

The objective of the present study is to investigate how elevated temperature ranging from $100^{\circ}C$ to $800^{\circ}C$ as well as room temperature affects the variation of mechanical properties of high strength concrete ($over\;f_{ck}=60MPa\;grade$). In this experiment, specimens were exposed for a period of $2^{\circ}C/min$ to temperatures of $20^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$ $400^{\circ}C$, $500^{\circ}C$, $600^{\circ}C$, $700^{\circ}C$ and $800^{\circ}C$, respectively. Accordingly, the study investigated the fire resistance performance of high strength concrete mixed with composite fibers which composed with hybrid fibers and steel fibers. After cooling down to ambient temperature, the following basic mechanical properties were then evaluated and compared with reference values obtained prior to thermal exposure: (i) compressive strength in room temperature; (ii) residual compressive strength; (iii) Poisson's ratio; (iv) weight change; (v) SEM analysis & XRD analysis In addition, XRD and SEM Images analyses were performed to investigate chemical and physical characteristics of high strength concrete with composite fibers according to high temperature.

본 연구는 섬유를 혼입한 고강도 콘크리트의 온도 변화에 따른 내화특성 분석에 관한 연구로 고강도 콘크리트에 고온이 가해질 경우 발생되는 폭렬현상에 대하여 방지효과가 있는 것으로 알려져 있는 하이브리드섬유와 강섬유를 함께 혼입하여 만든 복합섬유를 사용하여 온도 변화($100{\sim}800^{\circ}C$)에 따른 고강도 콘크리트의 내화특성 및 역학적 메커니즘을 분석하였다. 또한 본 논문에서는 고강도 콘크리트 구조물에서 가장 문제가 되는 폭렬현상을 막는 대책 중의 하나인 섬유 혼입을 통한 방법을 사용하여 SEM 및 XRD 분석 등의 방법으로 고온을 받은 고강도 콘크리트의 열적 특성 및 역학적 특성을 규명하고자 하였다.

Keywords

References

  1. Behnood, A., and Ghandehari, M. (2009), Comparison of Compressive and Splitting Tensile Strength of High-Strength Concrete with and without Polypropylene Fibers Heated to High Temperature, Fire Safety Journal, 44, 1015-1022. https://doi.org/10.1016/j.firesaf.2009.07.001
  2. Han, M. C., and Choi, H. K. (2011), The Effect on Mechanical Properties and Micro-structure of High Strength Concrete at Elevated Temperature, Journal of Architectural Institute of Korea, 27(3), 123-130.
  3. Han, C. G., and Kim, W. K. (2009), An Experimental Study on the Curing Method and PP Fiber Mixing Ratio on Spalling Resistance of High Strength Concrete, Journal of the Korea Institute of Building Construction, 9(6), 113-119. https://doi.org/10.5345/JKIC.2009.9.6.113
  4. Han, C. G., Kim, S. S., Kim, S. S., and Pei, C. C. (2008), Spalling Prevention of High Strength Concrete Due to Hybrid Organic Fiber and Different Lengths of Polypropylene Fibers, Journal of Architectural Institute of Korea, 24(2), 61-68.
  5. Jang, K. H., Pei, C. C., Jin, H. L., Jee, S. W., Yang, S. H., and Han, C. G. (2007), The fire resistance properties of the high strength concrete with various contents of nylon and polypropylene fibers, Proceeding of the Korea Institute for Structural Maintenance and Inspection, 11(1), 311-314.
  6. Kang, Y. H., Kang, C. H., Choi, H. G., Shin, H. J., and Kim, W. J.(2014), Compressive Properties of Ultra High Strength Concrete Exposed to High Temperature, Journal of the Korea Concrete Institute, 26(3), 377-384. https://doi.org/10.4334/JKCI.2014.26.3.377
  7. Kim, W. S., Kang, T. H.-K., and Kim, W. J. (2014), State-of- Art Research and Experimental Assessment on Fire-Resistance Properties of High Strength Concrete, Journal of the Korea Institute for Structural Maintenance and Inspection, 18(3), 28-39. https://doi.org/10.11112/jksmi.2014.18.3.028
  8. Kim, W. S., Kim, S. K., Lee, H. J., Lee, H. S., Kang, Y. H., and Kim, W. J. (2014), A Study of Characteristic Change of High Strength Concrete with Hybrid Fibers & Steel Fibers at High Temperature, Journal of the Korea Institute for Structural Maintenance and Inspection, 26(2), 435-436.
  9. Kim, H. Y., Seo, K. W., Lee, W. J., Kim, N. H., and Park, C. G. (2004), Effect of fiber blending on material property of hybrid fiber reinforced concrete, Proceedings of the Korea Concrete Institute, 16(2), 349-352
  10. Kim, J. H., Shin, Y. S., Moon, K. H., Park, C. G., and Kim, J. S. (2011), Fire Resistance Performance of High Strength Concrete Column with Hybrid Fiber Reinforcement, Journal of Architectural Institute of Korea, 27(5), 85-92.
  11. Kodur, V., and Sultan, M. A. (2003), Effect of Temperature on Thermal Properties of High-Strength Concrete, Journal of Materials in Civil Engineering, 15(2), 101-107. https://doi.org/10.1061/(ASCE)0899-1561(2003)15:2(101)
  12. Lee, H. S., Kang, Y. H., Kim, W. S., and Kim, W. J. (2014), Mechanical properties of high strength concrete mixed with hybrid fibers under high temperature, Proceeding of the Korea Concrete Institute, 26(2), 355-356.
  13. Park, J. M. (2009), An Experimental Study about Fire Resistance Characteristics of High Strength Concrete with Polypropylene Fiber and Steel Fiber, Master thesis, Konkuk Univ., Dept. of Architectural Engineering.
  14. Reis, M., Neves, I., Tadeu, A., and Rodrigues, J. (2001), High-Temperature Compressive Strength of Steel Fiber High-Strength Concrete, Journal of Materials in Civil Engineering, 13(3), 230-234. https://doi.org/10.1061/(ASCE)0899-1561(2001)13:3(230)
  15. Yoon, M. H., Kim, G. Y., Lee, T. G., Shin, K. S., Lee, W. J., and Lee, J. H. (2012), Spalling properties of ultra high strength concrete according to the melting and vaporization point of mixed fiber, Proceedings of the Korea Concrete Institute, 24(1), 865-866.