• Title/Summary/Keyword: evaluate a image

Search Result 2,306, Processing Time 0.034 seconds

The Use of the Unified Control Points for RPC Adjustment of KOMPSAT-3 Satellite Image (KOMPSAT-3 위성영상의 RPC보정을 위한 국가 통합기준점의 활용)

  • Ahn, Kiweon;Lee, Hyoseong;Seo, Doochun;Park, Byung-Wook;Jeong, Dongjang
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.5
    • /
    • pp.539-550
    • /
    • 2014
  • High resolution satellite images have to be oriented and geometrically processed from GCPs(Ground Control Points) to generate precise DEMs(Digital Elevation Models) and topographic maps. In Korea, thousands of national UCPS(Unified Control Points) are established and distributed all over the country by the Korean NGII(National Geographic Information Institute). For that reason, UCPs can be easily searched and downloaded by the national-control-point-record-issues system. Following the study, we suggested the sky-view and road-view from web-portals for searching and identifying UCPs on the images. To evaluate the usefulness of UCPs in RPCs(rational polynomial coefficients) adjustment of the high resolution satellite images, the one UCP, which of using simple the control point, has been applied to adjust the vendor-provided RPCs of the KOMPSAT-3 images. As a result, the positioning error of corrected RPCs was approximately one pixel and one meter. From this experiment, we conclude that the UCPs will be able to replace the survey GCPs for mapping with the satellite images or aerial images.

Study on Fabrication and Photoluminescent Properties of Fine Phosphor Film for Application of Radiation Image Sensor (방사선 영상센서 적용을 위한 미세 발광체 필름 제조 및 광학적 특성에 관한 연구)

  • Kang, Sang-Sik;Choi, Young-Zoon;Lee, Kwang-Oop;Moon, Yong-Soo;Kim, Mi-Young;Lee, Sang-Bong;Jung, Bong-Jae;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.25-28
    • /
    • 2010
  • In this paper, the fabrication and feasibility study of clinical application with euripium doped gadollium oxide ($Gd_2O_3$:Eu) nano phosphor derived by low-temperature solution combustion method. From the fabricated phosphor, the photoluminescent characteristic and linearity as a function of phosphor film thickness were investigated to evaluate x-ray converstion properties. From the experimental results, the luminescent intensity was $2945pC/cm^2$-mR at $270{\mu}m$ $Gd_2O_3$:Eu film and this value is higher 1.2 time the conventional bulk phosphor, which is possible to imaging acquisition. And good linearity was shown at x-ray exposure range for clinical diagnostic application.

A STUDY ON THE MICROLEAKAGE OF COMPOSITE RESIN AND GLASS IONOMER CEMENT WITH VARYING FILLING METHODS (수복방법에 따른 복합레진 및 글라스아이오노머 시멘트의 변연부 미세누출에 관한 연구)

  • Hwang, Ho-Keel;Park, Joo-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.174-186
    • /
    • 1996
  • The purpose of this study was to evaluate the adaptability to tooth structure of composite resin and glass ionomer cement according to filling methods. In this study. two class V cavities were prepared on the buccal and lingual surface of each tooth of forty extracted human premolars. and they were randomly assigned into 4 groups with 10 teeth. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin (Group 1). $Vitremer^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the $Vitremer^{TM}$ liner(Group 3). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling. specimens were immersed in 2% methylene blue solution and stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then. the specimens sectioned buccolingually. Degree of dye penetration at tooth-restoration interfaces were examined by Tool maker's microscope(x 200) and Image analyzer. The results were as follows : 1. On the occlusal margin. among the experimental groups. the group 2 showed the highest dye penetration($2.40{\pm}0.68$) and the group 3 showed the lowest dye penetration($1.15{\pm}0.37$). There was significant difference among the experimental groups(p<0.001). 2. On the gingival margin, among the experimental groups, the group 1 showed the highest dye penetration($3.30{\pm}0.57$) and the group 2 showed the lowest dye penetration($1.65{\pm}0.49$). There was significant difference among the experimental groups(p>0.001). 3. About total degree of dye penetration, the group 1 showed the highest dye penetration($2.25{\pm}1.17$) and the group 3 showed the lowest dye penetration ($1.43{\pm}0.55$). There was significant difference among the experimental groups(p<0.001). 4. The sum of dye penetration at occlusal margin was less than gingival margin. There was significant difference between occlusal margin and gingival margin (p<0.001). The results showed that differences were more pronounced at the gingival margin. Composite restorations inserted over the glass-ionomer liner demonstrated significantly less leakage than single restoration that used composite resin or glass-ionomer cement.

  • PDF

Imaging of Tumor Proliferation Using Iodine-131-Iodomethyluridine (Iodine-131-Iodomethyluridine을 이용한 종양세포증식의 영상화에 관한 실험적 연구)

  • Min Kyung-Yoon;Kim, Chang-Guhn;Kim, Hyun-Jeong;Lim, Hyung-Guhn;Rho, Ji-Young;Juhng Seon-Kwan;Won Jong-Jin;Yang, David J.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.344-350
    • /
    • 1996
  • Purpose : Noninvasive imaging of tumor cell proliferation could be helpful in the evaluation of tumor growth potential and could provide an early assessment of treatment response. Radiolabeled thymidine, uridine and adenosine have been used to evaluate tumor cell proliferation. These nucleoside analogs are incorporated into DNA during proliferation. Iodine-131-Iodomethyluridine, an analog of Iodine-131-Iododeoxyuridine, is also involved in DNA/RNA synthesis. The purpose of this study was to develop Iodine-131-Iodomethylurdine and image tumor proliferation using Iodine-131-Iodomethyluridine. Materials and Methods : Radiosynthesis of Iodine-131-5-Iodo-2'-O-methyluridine (Iodine-131-Iodomethyluridine) was prepared from 10 mg of 2'-O-methyluridine(Sigma chemical Co., St. Louis, Missouri) and 2.1 mCi(SP. 10Ci/mg) of Iodine-131-labeled sodium iodide in $100{\mu}l$ of water using iodogen reaction. Female Fischer 344 rats were inoculated in the thigh area with breast tumor cells(13765 NF, $10^5$ cells/rat S.C.). After 14 days, the Iodine-131-Iodomethyluridine $10{\mu}Ci$ was injected to three groups of rats(3/group). The percent of injected dose per gram of tissue weight was determined at 0.5-hours, 2-hours, 4-hours, and 24-hours respectively. Tumor bearing rats after receiving Iodine-131-Iodomethyluridine($50{\mu}Ci$ IV) were euthanized at 2 hours after injection. Autoradiography was done using freeze-dried $50{\mu}m$ coronal section. After injection of Iodine-131- Iodomethyluridine ($10{\mu}Ci$/rat, IV) in three breast tumor-bearing rats, planar scintigraphy was taken at 45 minutes, 90 minutes and 24 hours. Results : Iodine-131-Iodomethyluridine was conveniently synthesized using iodogen reaction. The biodistribution showed fast blood clearance and the tumor-to-tissue uptake ratios showed that optimal imaging time was at 2 hours postinjection. Autoradiogram and planar scintigram indicated that tumor could be well visualized. Conclusion : The findings suggest that Iodine-131-Iodomethyluridine, a new radio-iodinated nucleoside, has potential use for evaluation of active regions of tumor growth.

  • PDF

Mast Cells are Responsible for Expression of α-Smooth Muscle Actin in Stromal Cells of the Uterine Cervix during Epithelial Neoplastic Changes (자궁경부상피의 악성변화에서 비만세포가 간질세포의 α-Smooth Muscle Actin 발현에 미치는 영향)

  • Jekal, Seung-Joo;Choi, Young-Ja;Lee, Kwang-Joo;Roh, Jong-Sup
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • There is increasing evidence that stromal reaction in cancer has an important diagnostic and prognostic significance. The aim of our study is to analyze the relation between the increase in mast cell number and the expression CD34 and alpha-smooth muscle actin (${\alpha}$-SMA) in the stroma of cervical intraepithelial neoplasia (CIN) and squamous cell carcinoma (SCC). We investigated a total of 29 CIN (1,2,3) and 21 SCC (microinvasive and invasive) specimens and compared the distribution of $CD34^+$ stromal cells, ${\alpha}-SMA^+$ cells, transforming growth factor-${\beta}1$ $(TGF-{\beta}1)^+$ cells, and the density of mast cells using immunohistochemistry with antibodies against CD34, ${\alpha}$-SMA, TGF-${\beta}1$, and c-Kit (CD117) respectively. Computerized image analysis was to evaluate the positive area (%) and density of the respective immunoreactive cells. In CIN $CD34^+$ cells were abundant in the stroma but no ${\alpha}-SMA^+$ cells were identified except the wall of blood vessels. $CD34^+$ cells were progressively decreased along the continuum from CIN 2 to microinvasive SCC and not observed in the stroma of invasive SCC. Whereas ${\alpha}-SMA^+$ cells were only observed in the stroma of microinvasive and invasive SCC. We found more intense TGF-${\beta}1$ expression in the increased mast cells in the stroma of invasive SCCs than that in the stroma of CIN. These results indicate that disappearance of $CD34^+$ stromal cells and appearance of ${\alpha}-SMA^+$ cells are associated with the stromal change of CIN to SCC and the transformation of $CD34^+$ stromal cells into ${\alpha}-SMA^+$ cells is mediated by TGF-${\beta}1$ secretions in the stromal mast cell of SCC.

  • PDF

The Effect of Memory Load on Maintenance in Face and Spatial Working Memory: An Event-Related fMRI Study (기억부하가 얼굴과 공간 작업기억의 유지에 미치는 효과: 사건유관 fMRI 연구)

  • Kim, Jung-Hee;Jeong, Gwang-Woo;Kang, Heoung-Keun;Lee, Moo-Suk;Park, Tae-Jin
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.2
    • /
    • pp.359-386
    • /
    • 2010
  • In order to evaluate the domain-specific model and process-specific model of spatial and nonspatial working memory (WM), this study manipulated the memory load of the delayed response task and examined how the neural correlates of memory load effect was influenced by the stimulus domain (face and location) at the maintenance stage of WM using an event-related fMRI experiment. One or three face stimuli were presented as target stimuli and participants were asked to maintain the face itself (face WM) or the location of face stimuli (spatial WM). The results of recognition judgment accuracy showed no difference between face WM and spatial WM, and showed equivalent memory load effects of both WM. As a result of brian image analysis, memory load effect at maintenance stage showed that inferior, middle, and superior PFC were recruited by both face WM and spatial WM, and showed that VLPFC was the commonly activated area by both WM, supporting functional specialization of PFC by process components of WM. This study provides evidence for process-specific model in which maintenance of WM is associated with VLPFC.

  • PDF

THE EFFECT OF HUMAN DBM($GRAFTON^{(R)}$) GRAFT ON SKULL DEFECT IN THE RABBIT (가토의 두개골 결손부에 이식한 human DBM ($Grafton^{(R)}$)의 효과)

  • Kim, Jin-Wook;Park, In-Suk;Lee, Sang-Han;Kim, Chin-Soo;Jang, Hyun-Jung;Kwon, Tae-Geon;Kim, Hyun-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.2
    • /
    • pp.118-126
    • /
    • 2006
  • In oral and maxillofacial surgery, bone graft is very important procedure for functional and esthetic reconstruction. So, many researcher studied about bone graft material like autogenous bone, allograft bone and artificial bone materials. The purpose of this study is to evaluate the quantity of bone generation induced by $Grafton^{(R)}$ graft, human allogenic demineralized bone matrix. Total 24 sites of artificial bony defects prepared using trephin bur(diameter 8 mm) on parietal bone of six adult New Zealand White rabbits. Experimental group had six defect sites which grafted $Grafton^{(R)}$(0.1 cc). Active control group had nine defect sites, into which fresh autogenous bone harvested from own parietal bone was grafted and passive control group had nine defect sites without bone graft. After six weeks postoperatively, the rabbits were sacrificed. The defects and surrounding tissue were harvested and decalcified in 10% EDTA, 10% foamic-acid. Specimens were stained with H&E. New bone area percentage in whole defect area was measured by IMT(VT) image analysis program. Quantity of bone by $Grafton^{(R)}$ graft was smaller than that of autograft and larger than that of empty defects. In histologic view $Grafton^{(R)}$ graft site and autograft site showed similar healing progress but it was observed that newly formed bone in active control group was more mature. In empty defect, quantity and thickness of new bone formation was smaller than in $Grafton^{(R)}$-grafted defect. $Grafton^{(R)}$ is supposed to be a useful bone graft material instead of autogenous bone if proper maintenance for graft material stability and enough healing time were obtained.

Particle Spacing Analysis of Frozen Sand Specimens with Various Fine Contents by Micro X-ray Computed Tomography Scanning (Micro X-ray CT 촬영을 통한 동결 사질토 시료의 세립분 함유량에 따른 입자간 거리 분석)

  • Chae, Deokho;Lee, Jangguen;Kim, Kwang-Yeom;Cho, Wanjei
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.1
    • /
    • pp.31-35
    • /
    • 2017
  • The mechanical characteristics of frozen sand greatly depend on the frozen temperature and the fine contents according to the previous study by Chae et al. (2015). There are two hypotheses to explain this experimental results; one is the unfrozen water contents greatly affected by the fine contents and frozen temperature and the other is the sand particle spacing greatly affected by the pore-ice. To evaluate the latter hypothesis, the micro X-ray CT scan was performed. The micro X-ray CT scanning, one of the actively performed interdisciplinary research area, has a high resolution with micrometer unit allows to investigate internal structure of soils. In this study, X-ray CT technique was applied to investigate the effect of the frozen temperature and fine contents on the sand particle minimum and average spacing with the developed image processing techniques. Based on the spacing analysis, the frozen temperature and fine contents have little influence on the sand particle spacing in the frozen sand specimens.

Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue (소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가)

  • Choi, Kyunghwa;Kim, Misun;Lee, Koeun;Nam, Okhyung;Lee, Hyo-seol;Choi, Sungchul;Kim, Kwangchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2020
  • The purpose of this study was to evaluate the accuracy and precision of the three-dimensional (3D) imaging system of children's facial soft tissue by comparing linear measurements. The subjects of the study were 15 children between the ages of 7 and 12. Twenty-three landmarks were pointed on the face of each subject and 16 linear measurements were directly obtained 2 times using an electronic caliper. Two sets of 3D facial images were made by the 3D scanner. The same 16 measurements were obtained on each 3D image. In the accuracy test, the total average difference was 0.9 mm. The precision of 3D photogrammetry was almost equivalent to that of direct measurement. Thus, 3D photogrammetry by the 3D scanner in children had sufficient accuracy and precision to be used in clinical setting. However, the 3D imaging system requires the subject's compliance for exact images. If the clinicians provide specific instructions to children while obtaining 3D images, the 3D device is useful for investigating children's facial growth and development. Also the device can be a valuable tool for evaluating the results of orthodontic and orthopedic treatments.

Impact of Respiratory Motion on Breast Cancer Intensity-modulated Radiation Therapy (유방암 세기조절방사선치료에서의 호흡운동 영향)

  • Chung, Weon Kuu;Chung, Mijoo;Shin, Dong Oh;Kim, Dong Wook
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.93-97
    • /
    • 2016
  • In this study, we evaluate the effect of respiration on the dose distribution in patient target volume (PTV) during intensity-modulated radiation therapy (IMRT) and research methods to reduce this impact. The dose distributions, homogeneity index (HI), coverage index (CVI), and conformity index of the PTV, which is calculated from the dose-volume histogram (DVH), are compared between the maximum intensity projection (MIP) image-based plan and other images at respiration phases of 30%, 60% and 90%. In addition, the reducing effect of complication caused by patient respiration is estimated in the case of a bolus and the expended PTV on the skin. The HI is increased by approximately twice, and the CVI is relatively decreased without the bolus at other respiration phases. With the bolus and expended PTV, the change in the dose distribution of the PTV is relatively small with patient respiration. Therefore, the usage of the bolus and expended PTV can be considered as one of the methods to improve the accuracy of IMRT in the treatment of breast cancer patients with respiratory motion.