• Title/Summary/Keyword: evacuation measures

Search Result 109, Processing Time 0.026 seconds

A Study on the Development of Intelligent Guiding Exit Sign System (지능형 피난유도 시스템 개발에 관한 연구)

  • Kim, Yoo-Shik;Sug, Dong-Sub
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.131-134
    • /
    • 2006
  • As modern buildings grow to become diversified, toxic gases and smoke coupled with characteristics of space during a fire increase the risk of large-scaled disaster. It is now urgent to take measures for evacuation and escape directly linked to personal damage. Existing fixed one-way emergency exit light is not enough for efficient evacuation and rescue. Therefore, to ensure quicker escape and evacuation during a fire, two-way radio data system should be devised, which linked with fire detector, helps people in danger to escape quickly and is able to control by a central control system, and the system was found to enhance the efficiency of escape and contribute to safer escape.

Analysis of the Effectiveness of Emergency Response Measures during the Design Basis Accident of the Research Reactor 'HANARO' using MACCS2 Code (MACCS2 코드를 이용한 연구용원자로 '하나로' 설계기준사고시 비상대응조치 효과분석)

  • Lee, Goan-Yup;Kim, Jong-Su;Lee, Hae-Cho;Kim, Bong-Suk
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.2
    • /
    • pp.109-117
    • /
    • 2014
  • Nuclear emergency planning is to plan sheltering, evacuation and iodine prophylaxis for the residents living in the area where the emergency plan is needed, the area is confirmed based on the dose assessment using the source-term through an accident analysis and the data measured from meteorological tower. In this study, the does change before and after protective measures was assessed stochastically based on the one year meteorological data in the condition of the maximum hypothetical accident which can be considered at the research reactor 'HANARO', and the optimized protective measures were derived based on the reference levels defined as a residual dose by ICRP 2007 recommendation which can be applied in a emergency exposure situation. The optimized protective measures for the HANARO in the maximum hypothetical accident were the evacuation to radius 300 m, the sheltering from 300 m to 800 m, the iodine prophylaxis only for the emergency workers under the protective measures for non emergency workers.

Analyzing Accessibility of Emergency Shelters Based on Service Population: The Case of Outdoor Evacuation Places for Earthquake in Jung-gu, Seoul (생활인구를 고려한 대피시설 접근성 분석: 서울 중구지역 지진 옥외 대피장소를 사례로)

  • Kim, Sang-Gyoon;Shin, Sang-Young;Nam, Hyeon-Jung
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.51-62
    • /
    • 2022
  • Purpose: This study analyzes accessibility of outdoor evacuation places for earthquake and the accessibility improvement effects when expanding the evacuation places in accessibility-deficient areas. In order to consider real-world evacuees, the accessibility analysis is based on service population not on resident population. Method: Location-allocation model as a GIS-based spatial optimization mode is used to analyze accessibility and vulnerable areas to evacuation places. Of location-allocation problem types, 'Maximize Coverage' method is chosen to allocate as many potential evacuees as possible to evacuation places. And impedence cutoffs or evacuation distances (times) are applied to three classes: 500m (7.5 minutes), 1,000m (15 minutes), and 1,500m (22.5 minutes). Case study area is Jung-gu areas, Seoul as a high-density downtown area. Result: Results show that accessibility-deficient areas and population to evacuation places are much more in service population than in resident population. Accessibility is significantly improved when increases when expanding the evacuation places in accessibility-deficient areas. Yet, accessibility-deficient areas are still remained since available lands are insufficient in the high-density downtown area. Conclusion: The study suggests that temporary evacuation facilities like outdoor evacuation places for earthquake need to consider real potential evacuees based not only on resident population but also on service population. Also, policy measures to provide emergency shelters need to more utilize spatial optimization tools like location-allocation model.

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

A Study on Identifying Problems by the Comparative Analysis of High-Rise Apartment Evacuation Design Codes (고층 아파트 피난설계기준 비교분석을 통한 문제점 도출 연구)

  • Hwang, Eun-Kyoung;Seo, Dong-Goo
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.47-52
    • /
    • 2017
  • The recent tragic outbreak of fire at the Grenfell Tower in the United Kingdom compels all branches of government to reexamine and reassess the safety measures against fires in high-rise buildings from a broad perspective. Accordingly, this study examined what problems stem from the current evacuation codes by comparative analysis of the high-rise apartment evacuation codes that range over various individual laws before introducing a new evacuation code. The outcome of this study can be utilized as basic data for amending the existing evacuation codes for high-rise buildings. The codes related to high-rise building evacuation include the Building Act, the Housing Act, the Skyscraper Disaster Management Act, and the Fire-Fighting System Act. Some local governments have also drawn up their own codes and put them into practice. Comparative analysis of the major evacuation codes has helped identify a variety of problems, such as different codes being applied to each individual law and ordinance, the use of additional codes other than the provisions of laws and ordinances, and the in effectiveness of evacuation codes. Most of these problems occur when diverse codes are applied to a single building, which means that cooperation among the relevant ministries is urgently needed to improve the related codes in the future.

A Study on the Efficiency of Evacuation Exterior Stairs in High-rise Buildings (고층빌딩에서 옥외피난계단의 효용성에 관한 연구)

  • Choi, Kyu-Chool
    • Fire Science and Engineering
    • /
    • v.23 no.1
    • /
    • pp.63-69
    • /
    • 2009
  • Article 36 of the Building Code Enforcement Ordinance requires that an exterior evacuation stairs be installed for the buildings of three stories and over with cultural facilities or gathering places which have over $1,000\;m^2$ floor area of public performance halls or recreational facilities. The concentration of population together with the increase of high-rise buildings in cities call for various precautionary measures to be taken against human disasters. For the past ten years high-rise buildings showed 85% of increase, marking a steep rise. This increase of high-rise buildings may lead to human disasters in urban areas and, in case of fire breakout, may cause great loss of human lives and property damages. The most difficult fire-fighting activities in high-rise building fires are those of evacuation. Because smoke spreads through the upper floors, the securement of evacuation route in high-rise buildings may be the only way to minimize loss of lives. In high-rise buildings exterior escape stairs are necessary because it is difficult to secure evacuation route with only direct stairs or interior stairs. The Building Code now in force provides insignificant coverage on the exterior evacuation route installment and therefore becomes an inadequate means for evacuation route securement in high-rise building fires. To compensate for this inadequacy the Building Code should be revised to include a mandatory clause that an exterior evacuation stairs be established for the buildings of ten stories and over which can be categorized into high-rise building group.

Mapping Inundation Areas by Flash Flood and Developing Rainfall Standards for Evacuation in Urban Settings (GIS를 이용한 도시지역 돌발홍수 침수예상지도 작성 및 대피강우기준 개발)

  • Shin, Sang-Young;Yeo, Chang-Geon;Baek, Chang-Hyun;Kim, Yoon-Jong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.71-80
    • /
    • 2005
  • As local flash flood exceeding planned capacity occurs frequently, localized preparedness and response to flood inundation are increasingly important. Using XP-SWMM model and GIS techniques, this study analyzes inundation areas by local flash flood and develops rainfall standards for evacuation with the case of Sadang-Cheon area, a local stream and its nearby highly populated watershed in the southern part of metropolitan Seoul, Flood inundation areas overflowed from drainage systems are analyzed and mapped by amount of rainfall that is derived from reference levels of stream flow. Rainfall standards for evacuation are comprised of 'watch' (40mm/hr) in preparing for near-future inundation and 'evacuation' (65mm/hr) in responding to realized inundation. The methods suggested by this case study may be applied to other urban areas for sound flood prevention policy measures and thus risk minimization.

  • PDF

Status of Local Disaster Prevention by Regional Types - Focusing on Gangwon-do - (지역유형별 지역방재력에 관한 실태분석 - 강원도를 중심으로 -)

  • Kim, Kyoung-Nam;Kwon, Gun-Ju;Back, Min-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.33-46
    • /
    • 2010
  • The 14 cities and guns within Gangwon-do were divided into three regions (urban-rural-integrated type, urban type, and ruralcoastal type), and local voluntary disaster prevention organizations in those regions were surveyed as sample groups. As a result, the urban-rural-integrated type and the urban type were found to be lower than the rural-coastal type in all domains including recognition of disaster crisis, evacuation guidance, preparation of voluntary evacuation, maintenance of disaster prevention system, surveillance & guard, and information delivery. In particular, three types had higher information delivery but considerably lower preparation of voluntary evacuation. As for information delivery, foundations for rapid delivery of disaster information due to establishment and extension of systems for forecasting and warning of local governments were prepared, but as for preparation of voluntary evacuation, it is needed not only to perform consistent training and promotion for preparation for disasters for residents to accurately understand status of disasters but to take measures to secure safe places for evacuation beforehand.

Effectiveness of BIM-based Human Behavior Simulation on Architectural Design Education -Focused on Exploration and Evaluation of Barrier-Free and Fire Evacuation Performances- (BIM 기반의 인간행동 시뮬레이션이 건축설계교육에 미치는 효과에 관한 연구 -무장애와 안전 및 피난설계의 성능탐구와 평가를 중심으로-)

  • Hong, Seung-Wan;Park, Ji-Young
    • Journal of KIBIM
    • /
    • v.10 no.4
    • /
    • pp.1-10
    • /
    • 2020
  • While the importance of barrier-free and fire evacuation design is highlighted in architectural design education, systemic analysis, and examination on such performances are still challenging due to methodological lacks. The present study investigates the effectiveness of BIM-based human behavior simulation for architecture major students' analytical examinations to promote barrier-free and fire evacuation performances. To achieve such an aim, quasi-experiments were conducted, which compare 50 students' analysis and examination scores according to the use and non-use of the simulation, and the data were collected via participants' survey and interview. As a result, T-Test and MANOVA analyses indicate that, compared with its non-use counterpart, the use of human behavior simulation better facilitates the students' (1) examination of the physical properties and dimensions for the disabled's accessibility and evacuation, (2) understanding of the bodily capacity and handicap of the disabled, (3) examination on the spatial layouts and locations of exits, (4) understanding on evacuees' urgent behaviors, and (5) responsibility as an architect. Based on previous studies, the reasons of statistical results are interpreted as the explicit observation and analytical measures of multiple numbers of virtual-evacuees and direct-experience from body range of the disabled responding to the populated occupants as what they face in authentic reality.

Considerations of the Optimized Protective Action Distance to Meet the Korean Protective Action Guides Following Maximum Hypothesis Accidents of Major KAERI Nuclear Facilities

  • Goanyup Lee;Hyun Ki Kim
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.1
    • /
    • pp.52-57
    • /
    • 2023
  • Background: Korea Atomic Energy Research Institute (KAERI) operates several nuclear research facilities licensed by Nuclear Safety and Security Commission (NSSC). The emergency preparedness requirements, GSR Part 7, by International Atomic Energy Agency (IAEA) request protection strategy based on the hazard assessment that is not applied in Korea. Materials and Methods: In developing the protection strategy, it is important to consider an accident scenario and its consequence. KAERI has tried the hazard assessment based on a hypothesis accident scenario for the major nuclear facilities. During the assessment, the safety analysis report of the related facilities was reviewed, the simulation using MELCOR, MACCS2 code was implemented based on a considered accident scenario of each facility, and the international guidance was considered. Results and Discussion: The results of the optimized protective actions were 300 m evacuation and 800 m sheltering for the High-Flux Advanced Neutron Application Reactor (HANARO), the evacuation to radius 50 m, the sheltering 400 m for post-irradiation examination facility (PIEF), 100 m evacuation or sheltering for HANARO fuel fabrication plant (HFFP) facility. Conclusion: The results of the optimized protective actions and its distances for the KAERI facilities for the maximum postulated accidents were considered in establishing the emergency plan and procedures and implementing an emergency exercise for the KAERI facilities.