• Title/Summary/Keyword: equivalent link

Search Result 125, Processing Time 0.024 seconds

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

Optimal Pressure Condition and V-t Characteristic of Macro Interface between Epoxy and EPDM (Epoxy/EPDM 거시계면의 최적조건과 V-t 특성)

  • 박우현;이동규;이상극;안준호;김충혁;이기식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.439-442
    • /
    • 2002
  • The interface between two different materials in the insulation systems is the weak-link in the underground power transmission systems, In this paper, Optimum conditions of the interface between Epoxy and EPDM is studied. The variation factor condition of interface is roughness of surface, spreading of oils, interfacial pressure and temperature. The breakdown times under the constant voltage below the breakdown voltage were also gained. The breakdown voltage at the after laying time equivalent to is calculated by the V-t characteristic and the inverse power law. When this is done, the characteristic life exponent n is used and the long time breakdown voltage can be evaluated.

  • PDF

Design of a 2.5Gbps Serial Data Link CMOS Transceiver (2.5Gbps 시리얼 데이터 링크 CMOS 트랜시버의 설계)

  • 이흥배;오운택;소병춘;황원석;김수원
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1185-1188
    • /
    • 2003
  • This paper describes a design for a 2.5Gb/s serial data link CMOS transceiver based on the InfiniBand$^{TM}$ specification. The transceiver chip integrates data serializer, line driver, Tx PLL, deserializer, clock recovery, and lock detector. The designed transceiver is fabricated in a 0.25 ${\mu}{\textrm}{m}$ CMOS mixed-signal, 1-poly, 5-metal process. The first version chip occupies a 3.0mm x 3.3mm area and consumes 450mW with 2.5V supply. In 2.5 Gbps, the output jitter of transmitter measured at the point over a 1.2m, 50Ω coaxial cable is 8.811ps(rms), 68ps(p-p). In the receiver, VCO jitter is 18.5ps(rms), 130ps(p-p), the recovered data are found equivalent to the transmitted data as expected. In the design for second version chip, the proposed clock and data recovery circuit using linear phase detector can reduce jitter in the VCO of PLL.L.

  • PDF

Call control considering other cell interference and multi-rate traffic in DS-CDMA cellular systems (DS-CDMA 셀룰라 시스템에서 외부셀 간섭 및 multi-rate traffic을 고려한 호 제어)

  • 전형구;권수근;강창언
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.1-8
    • /
    • 1997
  • In this paper, we propose a call admission control scheme which can be used in real environment for the traffic cibtrik if a base station if DS-CDNA cellular systems. The proposed scheme estimates the mean and variance of other cell interference by using the values used for the closed loop power control. The reerse link capacity of the base station can be calculated by using the estimated mean and variance of other cell interference. The base station admits a call only if the number of users is less than the calculated reverse link capacity. In addition, we propose a simple method to obtain the equivalent number of voice call users per one data call user in multi-rate traffic environment. The method can be applied to call admission control in multi-rate traffic environment.

  • PDF

Erlang Capacity Analysis For DS/CDMA Cellular System Considering Multipath Fading (다중경로 페이딩을 고려한 DS/CDMA 셀룰라 시스템의 얼랑용량 분석)

  • Kim, Hang-Rae;Kim, Nam
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.126-129
    • /
    • 1999
  • In this paper, it is assumed that a mobile radio channel is a Rayleigh distributed multipath fading channel and Erlang capacity and equivalent channel numbers are calculated for the reverse link of a imperfect power controlled DS/CDMA cellular system considering both shadowing and multipath fading. The DS/CDMA blocking probability is calculated based on a new analysis method that considers Erlang capacity and ICF(interference correction factor) using the median value of $E_{b(i)}$/ $I_{o}$ corresponding to each reverse link user. It is showed that the effect of multipath fading must not be ignored in Erlang capacity of the IS-95 DS/CDMA cellular system and the Erlang capacity is decreased according to the increase of the deviation of the imperfect power control, to the decrease of the processing gain, to the increase of the voice activity.y.

  • PDF

Vibration Control of a Very Flexible Robot Arm-via Piezoactuators (압전 작동기를 이용한 매우 유연한 로봇 팔의 진동 제어)

  • 신호철;최승복
    • Journal of KSNVE
    • /
    • v.6 no.2
    • /
    • pp.187-196
    • /
    • 1996
  • A new control strategy to actively control the vibration of a very flexible single link manipulator is proposed and experimentally realized. The control scheme consists of two actuators; a motor mounted at the beam hub and a piezoceramic bonded to the surface of the flexible link. The control torque of the motor to produce a desired angular motion is firstly determined by employing a sliding mode control theory on the equivalent rigid dynamics. The torque is then applied to the flexible manipulator in order to activate the commanded motion. During the motion, underirable oscillation is actively suppressed by applying a feedback control voltage to the piezoceramic actuator. Consequently, the desired tip position is favorably accomplished without vibration. Measured control responses are presented in order to demonstrate the efficiency of the proposed control methodology.

  • PDF

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.

Two-Link Manipulator Control Using Indirect Adaptive Fuzzy Controller

  • N., Waurajitti;J., Ngamwiwit;T., Benjanarasuth;H., Hirata;N., Komine
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.445-445
    • /
    • 2000
  • This paper proposes the MIMO indirect adaptive fuzzy controller to control the two-link manipulators. The input-output linearization technique, equivalent control input plus integral term, augmented error model and recursive least square adaptive law are used fer the controller. The linear type of fuzzifier-defuzzifier fuzzy logic system used for nonlinear function makes easy to farm the error model and able to follow the adaptive system approach. Such that control approach, the control system is not required joint speed and accerelation measurement and easy to implement and tune. The simulation results showed that the proposed controller has good control performance, stability, very small tracking error, decoupling, fast convergence, robust to parameter variation and load.

  • PDF

Development of a Dimming Ballast for Electrodeless Fluorescent Lamps by Controlling DC-Link Voltage (직류링크전압가변에 의한 무전극램프의 조광제어 안정기 개발)

  • Jang, Mog-Soon;Lim, Byoung-Loh;Shin, Dong-Seok;Lee, Young-Man;Park, Chong-Yeun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.103-109
    • /
    • 2008
  • This paper presents a new method for designing a ballast that can provide dimming control of an electrodeless fluorescent lamp. Frequency control of lamp power is inappropriate because the lamp coefficients such as equivalent impedance, coupling coefficient of the transformer, and plasma resistance are a function of lamp power. In this paper, the dimming is achieved by controlling the DC_Link voltage in relation to the lamp power. The DC_Link voltage is controlled by a buck converter. Simulation and experimental results of the proposed design method are presented in order to validate the proposed method.

Traffic Accident Analysis of Link Sections Using Panel Data in the Case of Cheongju Arterial Roads (패널자료를 이용한 가로구간 교통사고분석 - 청주시 간선도로를 사례로 -)

  • Kim, Jun-Young;Na, Hee;Park, Byung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.3
    • /
    • pp.141-146
    • /
    • 2012
  • This study deals with the accident model using panel data which are composed of time series data of 2005 through 2007 and cross sectional data of link sections in Cheongju. Panel data are repeatedly collected over time from the same sample. The purpose of the study is to develop the traffic accident model using the above panel data. In pursuing the above, this study gives particular attentions to deriving the optimal models among various models including TSCSREG (Time Series Cross Section Regression). The main results are as follows. First, 8 panel data models which explained the various effects of accidents were developed. Second, $R^2$ values of fixed effect models were analyzed to be higher than those of random effect models. Finally, such the variables as the sum of the number of crosswalk on intersections and sum of the number of intersections were analyzed to be positive to the accidents.