• Title/Summary/Keyword: equipment and materials

Search Result 1,795, Processing Time 0.034 seconds

Determinants of R&D Performance of Government-supported Research Institutes in the Field of Science and Technology - A Case Study of the Korea Institute of Science and Technology (KIST) - (과학기술계 정부출연연구기관의 연구개발성과 결정요인 - 한국과학기술연구원 (KIST) 사례연구 -)

  • Choi, Ho-Young;Choi, Chi-Ho;Kim, Jung-Soo
    • Journal of Korea Technology Innovation Society
    • /
    • v.14 no.4
    • /
    • pp.791-812
    • /
    • 2011
  • The aim of this paper is to address the factors that influence R&D performance of the Korea Institute of Science and Technology (KIST), the representative government-supported research institute in Korea, through an empirical case study. Using the KIST R&D project data from 2004 to 2008, we investigate the determinants of R&D performance through a logistic regression analysis, and compare the results with the survey data we collected from researchers. Our results indicate that total budget, high rate of temporary researchers, and the outcome of the research director's past publications affect publishing performance, while the size of equipment, materials expenditure, and whether the research is outsourced or not affect patent registration performance and technology transfer performance. Contrary to expectations, major factors of publishing performance and that of patent performance are different respectively, and even the results of the survey data we collected from researchers show the difference. Accordingly, the findings of our study suggest the need for research institutes to consider facilitating communication with researchers and enhancing research policy analysis for improving R&D performance.

  • PDF

Effectiveness of an Environment-friendly Fumigator for Microorganisms that Can Cause Biological Damage to Records in Japan, Malaysia, and Oman (일본, 말레이시아, 오만의 기록물에서 분리한 유해미생물에 대한 친환경 기록물 소독장비 효과검증)

  • Kim, Min Ji;Lee, Eon Sook;Choi, Young Nam;Choi, Young Sin
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.15 no.2
    • /
    • pp.165-179
    • /
    • 2015
  • Archives have historical and academic values. That is why the study of preservation conditions and the environment for the effective management of various records progress. However, materials such as paper and adhesives will inevitably cause biological damages. These damages spread into the inner side of archives, which would make it impossible to recover. For example, archival records from Malaysia and Oman are easily exposed to biological damage because of these countries' hot and humid climate. As such, once records are damaged, disinfection operations are customary in these areas. Methyl bromide (MeBr) and ethylene oxide (EtO) were used in the disinfection process as they showed good insecticidal effect. However their antibacterial effect are negligible. As such, the need for an environmental-friendly fumigator was evident. An environmental-friendly fumigator is designed to improve storage stability. Such equipment is expected to contribute to prevention of damages to cultural heritages through its use of vaporization technology, maintenance of a disinfection space (chamber), and self-generation of nitrogen.

Static and Fatigue Characteristics of Urethane Foam Cored Sandwich Structures (우레탄 폼 코아 샌드위치 구조물의 정적 및 피로 특성)

  • 김재훈;이영신;박병준;김덕회;김영기
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.74-82
    • /
    • 1999
  • The static and fatigue characteristics of polyurethane foam cored sandwich structures are investigated. Three types of the specimens with the glass fabric faces and the polyurethane foam core are used; non-stitched. stitched, and stiffened sandwich specimen. Especially additional structural reinforcements with the twisted polyester and glass fiber for thickness direction are made to stitched sandwich structure panel to minimize the delamination of structure which is stitched the upper and lower faces through the core and the resin is impregnated Into stitched fiber with the characteristics of low viscosity of resin at resin flow temperature and cured together with during the curing process. Bending strength of stitched specimen which is 50 mm $50{\times}50{\;}mm$ pitched is improved by 50 % as com-pared with non-stitched specimen and stiffened specimen is improved 10 times more than non-stitched structure. After fatigue testing of $10^6$cycles by 20% of ultimate load under monotonic load, the bending fatigue strength of non-stitched specimen is decreased by 27% of monotonic bending strength, 39% for stitched structure and 20% for stiffened specimen. To verify the aging effect of polyurethane form core, Ultrasonic C-scanning equipment is used to detect the damage of skin laminate alone after fatigue test. From results of UT C-scan images, there is no defect that can be damaged occurred during fatigue test. It is concluded that the decrease of bending strength for foam cored sandwich specimen is caused by the decrease of stiffness due to the aging of polyurethane foam core during fatigue cycles.

  • PDF

Analysis of Injection Efficiency for Cement Grouts by Model Test of Permeation in Soil (지반침투모형시험에 의한 시멘트그라우트의 주입성능 분석)

  • Song, Young-Su;Lim, Heui-Dae;Choi, Dong-Nam
    • Economic and Environmental Geology
    • /
    • v.43 no.2
    • /
    • pp.177-184
    • /
    • 2010
  • When cement grout is used for waterproofing of grounds, important roles are played by fluidity, particle size and bleeding. The most important element which determines their characteristics is the water/cement ratio of grout. Moreover in order to improve the efficiency of soil permeation, micro cement with a smaller average diameter is used in addition to ordinary portland cement. Besides the mixing ratio and cement diameter, the condition of ground is also of fundamental importance in the efficiency of permeation. In order to evaluate grout in terms of permeation ability into ground, we need a field test of grounting, which is cost and time consuming. In this paper we present a laboratory test method in which the suitability and efficiency of grouts are simply and more practically tested. In Korea neither a test standard nor devices are available to simulate grouting in a laboratory. We devised a grout injection equipment in which grouting was reproduced in the same condition with different materials, and suggested a standard for the production of specimens. Our tests revealed that the efficiency of injection increases with the water/cement ratio. We also found that more efficiently injected is the grout with the order of decreasing size; MS8000, micro cement, and ultra fine cements, and colloidal super cement.

Direct Bonding of SillSiO2/Si3N4llSi Wafer Fairs with a Fast Linear Annealing (선형가열기를 이용한 SillSiO2/Si3N4llSi 이종기판쌍의 직접접합)

  • 이상현;이상돈;송오성
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.4
    • /
    • pp.301-307
    • /
    • 2002
  • Direct bonded SOI wafer pairs with $Si ll SiO_2/Si_3N_4 ll Si$ the heterogeneous insulating layers of SiO$_2$-Si$_3$N$_4$are able to apply to the micropumps and MEMS applications. Direct bonding should be executed at low temperature to avoid the warpage of the wafer pairs and inter-diffusion of materials at the interface. 10 cm diameter 2000 ${\AA}-SiO_2/Si(100}$ and 560 $\AA$- ${\AA}-Si_3N_4/Si(100}$ wafers were prepared, and wet cleaned to activate the surface as hydrophilic and hydrophobic states, respectively. Cleaned wafers were pre- mated with facing the mirror planes by a specially designed aligner in class-100 clean room immediately. We employed a heat treatment equipment so called fast linear annealing(FLA) with a halogen lamp to enhance the bonding of pre mated wafers We kept the scan velocity of 0.08 mm/sec, which implied bonding process time of 125 sec/wafer pairs, by varying the heat input at the range of 320~550 W. We measured the bonding area by using the infrared camera and the bonding strength by the razor blade clack opening method, respective1y. It was confirmed that the bonding area was between 80% and to 95% as FLA heat input increased. The bonding strength became the equal of $1000^{\circ}C$ heat treated $Si ll SiO_2/Si_3N_4 ll Si$ pair by an electric furnace. Bonding strength increased to 2500 mJ/$\textrm{m}^2$as heat input increased, which is identical value of annealing at $1000^{\circ}C$-2 hr with an electric furnace. Our results implies that we obtained the enough bonding strength using the FLA, in less process time of 125 seconds and at lowed annealing temperature of $400^{\circ}C$, comparing with the conventional electric furnace annealing.

Designing a Molecular Diagnostic Laboratory for Testing Highly Pathogenic Viruses (고병원성 바이러스 검사를 위한 분자진단검사실 구축)

  • Jung, Tae Won;Jung, Jaeyoung;Kim, Sunghyun;Kim, Young-Kwon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.2
    • /
    • pp.143-150
    • /
    • 2021
  • The recent spread of novel and highly variant pathogenic viruses, including the coronavirus (SARS-CoV-2), has increased the demand for diagnostic testing for rapid confirmation. This has resulted in investigating the functional capability of each space, and preparing facility guidelines to secure the safety of medical technologists. During viral evaluations, there is a requirement of negative pressure facilities along with thread separation, during pre-treatment of samples and before nucleic acid amplification. Space composition therefore needs to be planned by considering unidirectional air flow. This classification of safety management facilities is designated as biosafety level 2, and personal protective equipment is placed accordingly. In case of handling dangerous materials, they need to be carried out of the biosafety cabinet, and sterilizers are required for suitable disposal of infectious agents. A common feature of domestic laboratories is maintenance of the sample pre-treatment space at a negative pressure of -2.5 Pa or less, and arranging separate pre-treatment and reagent preparation spaces during the test process. We believe that the data generated in this study is meaningful, and offers an efficient direction and detailed flow for separation of the inspection process and space functions. Moreover, this study introduces construction of the laboratory by applying the safety management standards.

Development of Real-Time Scheduling System for OHT Mission Planning (OHT 작업 계획을 위한 실시간 스케줄링 시스템 개발)

  • Lee, Bok-Ju;Park, Hee-Mun;Kwon, Yong-Hwan;Han, Kyung-Ah;Seo, Kyung-Min
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.7
    • /
    • pp.205-214
    • /
    • 2021
  • For smart manufacturing, most semiconductor sites utilize automated material handling systems(AMHS). As one of the AMHSs, the OHT control system(OCS) manages overhead hoist transports(OHT) that move along rails installed on the ceiling. This paper proposes a real-time scheduling system to efficiently allocate and control the OHTs in semiconductor logistics processes. The proposed system, as an independent subsystem within the OCS, is interconnected with the main subsystem of the OCS, so that it can be easily modified without the effect of other systems. To develop the system, we first identify the functional requirements of the semiconductor logistics process and classify several types of control scenarios of the OHTs. Next, based on SEMI(Semiconductor Equipment and Materials International) standard, we design sequence diagrams and interface messages between the subsystems. The developed system is interoperated with the OCS main subsystem and the database in real time and performs two major roles: 1) OHT dispatching and 2) pathfinding. Six integrated tests were carried out to verify the functions of the developed system. The system was normally operated on six basic scenarios and two exception scenarios and we proved that it is suitable for the mission planning of the OHTs.

Assessment of the Coupled Electric-Thermal Numerical Model for Microwave Sintering of KLS-1 (한국형 인공월면토(KLS-1) 마이크로파 소결을 위한 전기장-열 연계해석 모델 평가)

  • Jin, Hyunwoo;Go, Gyu-Hyun;Lee, Jangguen;Shin, Hyu-Soung;Kim, Young-Jae
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.5
    • /
    • pp.35-46
    • /
    • 2022
  • The in-situ resource utilization (ISRU) for sustainable lunar surface and deep space explorations has recently gained attention. Also, research on the development of construction material preparation technology using lunar regolith is in progress. Microwave sintering technology for construction material preparation does not require a binder and is energy efficient. This study applies microwave sintering technology to KLS-1, a Korean lunar simulant. It is crucial to secure the homogeneity to produce a sintered specimen for construction material. Therefore, understanding the interactions between microwaves, cavities, and raw materials is required. Using a numerical model in terms of efficient assessment of several cases and establishment of equipment operating conditions is a very efficient approach. Therefore, this study also proposes and verifies a coupled electric-thermal numerical model through cross-validation and comparison with experimental results. The numerical model proposed in this study will be used to present an efficient method for producing construction material using microwave sintering technology.

Evaluation of Carryover Contamination on Autopipetting System (자동분주기의 이월오염 평가)

  • Lee, Hyun-Ju;Min, Gyung-Sun;Shin, Sun-Young;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.189-192
    • /
    • 2009
  • Purpose: Autopipetting system is an efficient automated equipment pipetting patient samples and reagents for rapid and accurate test. However, it can cause carryover between high concentration sample and low concentration sample. We evaluated carryover contamination of TECAN freedom Evo 100 autopipetting system. Materials and Method: We studied carryover contamination of $\alpha$-fetoprotein (AFP) and carcinoembryonic antigen (CEA) test on TECAN freedom Evo 100 autopipetting system. Very low concentration control samples were pipetted for comparison to the contaminated very low concentration samples. Then, The contaminated very low concentration samples were pipetted following the high concentration samples were pipetted alternately. The difference of low concentration samples represents carryover. The target value to decide carryover was 1ppm (parts per million). Results: For AFP, the mean values of the uncontaminated control samples and the contaminated samples were less than 0.6 IU/mL (the l imit of detection (LoD)). Carryover did not occur even though the high concentration sample which value was 650000 IU/mL. For CEA, the values of the low concentration control samples and the contaminated samples were less than 0.2 ng/mL (LoD). Carryover did not occur even though the high concentration sample which value was 65,000 ng/mL. Conclusions: Sample carryover was not found on TECAN freedom Evo 100 autopipetting system for AFP, CEA. However, carryover is a potential problem with automated instruments and robotic pipetting systems. Therefore, Clinical laboratories must periodically verify carryover contamination for the accurate and confidential test results.

  • PDF

A Study on the Contact Resistance according to the Tightening and Overlapping area of Bus Bar (부스 바의 체결 및 중첩 구간에 따른 접촉 저항에 관한 연구)

  • Kim, Hyun-Woo;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.56-62
    • /
    • 2018
  • The bus bar is an electrical connection widely used for the power supply of skyscrapers and power distribution and industrial equipment electrical panels in industrial plants. There are various materials to be considered in the design of the bus bar, such as material based on the use environment, the sectional area according to the power capacity, the length of the surface circumference, and the tightening method. Even with a bus bar manufactured to a size of sufficient power capacity in the design, if the actual tightening is incorrect, it may lead to fire due to deterioration. For these reasons, a variety of research on the temperature rise of the electrical contact point has continued. However, the temperature rise of the contacts is a consequence of the result, not a direct cause. In this paper, the influence of contact resistance on the fastening force and the overlapping section of the bus bar are investigated by measuring the change in resistance from building the specimen. A total of eight bus bar specimens were manufactured and measured. Resistance was measured by varying the clamping force and the interval between overlapping sections when the specimens were crossed. We propose a safe power connection model by analyzing the contribution of these factors to the actual contact resistance change.