• 제목/요약/키워드: energy FWHM

검색결과 163건 처리시간 0.027초

Characteristics of $In_xGa_{1-x}N/GaN$ single quantum well grown by MBE

  • Kang, T.W.;Kim, C.O.;Chung, G.S;Eom, K.S.;Kim, H.J.;Won, S.H.;Park, S.H.;Yoon, G.S.;Lee, C. M.;Park, C.S.;Chi, C.S.;Lee, H.Y.;Yoon, J.S.
    • 한국진공학회지
    • /
    • 제7권s1호
    • /
    • pp.15-19
    • /
    • 1998
  • Structural and optical properties of $In_xGa_{1-X}N$ as well as $In_{0.1}Ga_{0.9}N$/GaN single quantum we11 (SQW) grown on sapphire (0001) substrate with an based GaN using rf-plasma assisted MBE have been investigated. The quality of the InXGal.,N fdm was improved as the growth temperature increased. In PL measurements at low temperatures, the band edge emission peaks of $In_xGa_{1-X}N$ was shifted to red region as an indium cell and substrate temperature increased. For $In_{0.1}Ga_{0.9}N$/GaN SQW, the optical emission energy has blue shift about 15meV in PL peak, due to the confined energy level in the well region. And, the FWHM of the $In_{0.1}Ga_{0.9}N$/GaN SQW was larger than that of the bulk Ino,la.9N films. The broadening of FWHM can be explained either as non-uniformity of Indium composition or the potential fluctuation in the well region. Photoconductivity (PC) decay measurement reveals that the optical transition lifetimes of the SQW measured gradually increased with temperatures.

  • PDF

Effects of Growth Rate and III/V Ratio on Properties of AlN Films Grown on c-Plane Sapphire Substrates by Plasma-Assisted Molecular Beam Epitaxy

  • Lim, Se Hwan;Shin, Eun-Jung;Lee, Hyo Sung;Han, Seok Kyu;Le, Duc Duy;Hong, Soon-Ku
    • 한국재료학회지
    • /
    • 제29권10호
    • /
    • pp.579-585
    • /
    • 2019
  • In this study, we investigate the effect of Al/N source ratios and growth rates on the growth and structural properties of AlN films on c-plane sapphires by plasma-assisted molecular beam epitaxy. Both growth rates and Al/N ratios affect crystal qualities of AlN films. The full width at half maximum (FWHM) values of ($10{\bar{1}}5$) X-ray rocking curves (XRCs) change from 0.22 to $0.31^{\circ}$ with changing of the Al/N ratios, but the curves of (0002) XRCs change from 0.04 to $0.45^{\circ}$ with changing of the Al/N ratios. This means that structural deformation due to dislocations is slightly affected by the Al/N ratio in the ($10{\bar{1}}5$) XRCs but affected strongly for the (0002) XRCs. From the viewpoint of growth rate, the AlN films with high growth rate (HGR) show better crystal quality than the low growth rate (LGR) films overall, as shown by the FWHM values of the (0002) and ($10{\bar{1}}5$) XRCs. Based on cross-sectional transmission electron microscope observation, the HGR sample with an Al/N ratio of 3.1 shows more edge dislocations than there are screw and mixed dislocations in the LGR sample with Al/N ratio of 3.5.

ZnO 기반의 투명 박막 트랜지스터 제작을 위한 Active-layer의 최적화에 대한 연구 (Optimization of active layer for the fabrication of transparent thin film transistor based on ZnO)

  • 장성필;이상규;손창완;임재현;송용원;주병권;이상렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.94-95
    • /
    • 2007
  • We have observed electrical properties of ZnO thin films for the fabrication of transparent thin film transistor. ZnO thin films were deposited on $Al_2O_3$(0001) substrate at various temperatures by pulsed laser deposition(PLD). The third of harmonic(355nm) Nd:YAG laser was used for pulsed laser deposition. X-ray diffraction(XRD), field emission-scanning electron microscope(FE-SEM), and photoluminescence were used to characterize physical and optical properties of ZnO thin film.. The results indicated the ZnO film showed good optical properties as increasing temperatures, with low FWHM of exciton-related peak and XRD(0002) peak.

  • PDF

SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가 (The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels)

  • 신병호;김승정;윤석환;김태엽;임정진;우재룡;오소원;김유경
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.53-58
    • /
    • 2013
  • 본 연구에서는 각기 다른 에너지의 방사성동위원소를 이용하여 CT를 기초로 한 attenuation correction (AC)과 scatter correction (SC)을 적용했을 때 영상의 질을 비교분석하고 영상보정기법의 유용성에 대해 알아보고자 하였다. Resolution 평가를 위해 사용된 spatial resolution phantom 내부에 물을 채우고 각각의 동위원소 $^{99m}Tc$ (140 keV, 2.22 kBq), $^{201}Tl$ (70 keV, 2.22 kBq), $^{131}I$ (364 keV, 2.22 kBq)을 line에 주입하여 제작하였다. Contrast 평가를 위해 이용한 Jaszczak phantom은 배후방사능과 열소원통의 비율이 1:8이 되도록 각각의 동위원소를 주입하여 제작하였다. GE Infinia Hawkeye4 SPECT/CT (GE Medical System, USA)로 영상을 획득하고, non-correction (NC), AC, SC, AC와 SC가 동시에 적용된(ACSC) 4가지 조건으로 OSEM (2 iterations, 10 subsets)을 이용하여 영상을 각각 재구성하였다. FWHM값은 paired samples t-test를 통하여 유의수준 관계를 분석하였고, percent contrast (%)값은 MATLAB (Ver.7.0)$^{(R)}$과 MRIcro$^{(R)}$를 이용하여 각각의 수치를 비교하였다. $^{99m}Tc$의 resolution test에서 NC, AC, SC, ACSC를 각각 적용했 을 때 FWHM (mm)값은 각각 $4.97{\pm}0.46$, $4.73{\pm}0.27$, $49.7{\pm}0.39$, $4.60{\pm}0.26$, $^{201}Tl$에서는 $5.26{\pm}0.28$, $5.14{\pm}0.21$, $5.25{\pm}0.25$, $5.05{\pm}0.23$, $^{131}I$에서는 $6.24{\pm}0.73$, $5.84{\pm}0.57$, $6.24{\pm}0.69$, $5.98{\pm}0.52$의 값을 얻을 수 있었다. 각 방사성 동위원소의 결과 값에서 NC와 비교하여 AC, ACSC를 적용했을 때 통계적으로 유의한 차이를 보였고(P<0.05), SC만을 적용했을 때는 유의한 차이가 없음을 보여주었다(P>0.05). Contrast test에서는 percent contrast(%) 를 4개의 원통에 대한 값을 구했고, NC와 비교했을 때 AC, SC, ACSC의 percent difference (%)가 $^{99m}Tc$은 24.73, 38.10, 67.31, $^{201}Tl$은 30.90, 51.82, 86.02, $^{131}I$에서는 18.60, 46.26, 73.67의 차이를 보였다. 본 연구의 결과에 따르면 $^{99m}Tc$, $^{201}Tl$ 과 같은 낮은 에너지를 가진 핵종에 대해서는 ACSC를 동시에 적용한 영상에서 resolution 향상이 가장 크게 나타났지만, $^{131}I$ 같은 높은 에너지의 핵종에서는 AC만 적용되었을 때 ACSC를 적용했을 때보다 영상의 질이 더 향상됨을 알 수 있었다. 그러므로 SPECT/CT 검사 시 사용되는 핵종의 에너지에 따라 적절한 영상보정기법을 적용한다면 정확한 진단을 위한 최적의 영상을 얻을 수 있을 것으로 사료된다.

  • PDF

non-polar a-plane GaN growth on r-plane sapphire substrate by MOCVD

  • Son, Ji-Su;Baek, Kwang-Hyun;Kim, Ji-Hoon;Song, Hoo-Young;Kim, Tae-Geun;Hwang, Sung-Min
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.229-229
    • /
    • 2010
  • We report a high crystalline nonpolar a-plane (11-20) GaN on r-plane (1-102) sapphire substrates with $+0.15^{\circ}$, $-0.15^{\circ}$, $+0.2^{\circ}$, $-0.2^{\circ}$ and $+0.4^{\circ}$ misoriented by metalorganic chemical-vapor deposition (MOCVD). The multi-quantum wells (MQWs) active region is consists of 5 periods the nonpolar a-plane InGaN/GaN (a-InGaN/GaN) on a high quality a-plane GaN (a-GaN) template grown by using the multibuffer layer technique. The full widths at half maximum (FWHMs) of x-ray rocking curve (XRC) obtained from phiscan of the specimen that was grown up to nonpolar a-plane GaN layers with double crystal x-ray diffraction. The FWHM values of $+0.4^{\circ}$ misoriented sapphire substrate were decreased down to 426 arc sec for $0^{\circ}$ and 531 arc sec for $-90^{\circ}$, respectively. Also, the samples were characterized by photoluminescence (PL).

  • PDF

Impact of aperture-thickness on the real-time imaging characteristics of coded-aperture gamma cameras

  • Park, Seoryeong;Boo, Jiwhan;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1266-1276
    • /
    • 2021
  • The mask parameters of a coded aperture are critical design features when optimizing the performance of a gamma-ray camera. In this paper, experiments and Monte Carlo simulations were performed to derive the minimum detectable activity (MDA) when one seeks a real-time imaging capability. First, the impact of the thickness of the modified uniformly redundant array (MURA) mask on the image quality is quantified, and the imaging of point, line, and surface radiation sources is demonstrated using both cross-correlation (CC) and maximum likelihood expectation maximization (MLEM) methods. Second, the minimum detectable activity is also derived for real-time imaging by altering the factors used in the image quality assessment, consisting of the peak-to-noise ratio (PSNR), the normalized mean square error (NMSE), the spatial resolution (full width at half maximum; FWHM), and the structural similarity (SSIM), all evaluated as a function of energy and mask thickness. Sufficiently sharp images were reconstructed when the mask thickness was approximately 2 cm for a source energy between 30 keV and 1.5 MeV and the minimum detectable activity for real-time imaging was 23.7 MBq at 1 m distance for a 1 s collection time.

$^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성 (Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$)

  • 신채호;표성재;김봉수;조용귀;조진우;김창호
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.65-71
    • /
    • 2011
  • 근래의 심근 관류 SPECT를 위한 검사 장비는 진단의 정확도가 높아졌을 뿐만 아니라 검사 시간을 단축함으로써 환자의 편의성을 높이고 움직임에 대한 artifact를 줄이는 방향으로 발전되고 있다. 본 연구에서는 기존의 심근 관류 SPECT와 비교하여 IQ SPECT에 맞는 protocol을 design 하고 IQ SPECT의 특성과 유용성에 대하여 알아 보고자 하였다. Simens사의 Symbia T6 SPECT/CT를 이용하여 LEHR collimator와 Multiple confocal collimator에 대하여 acrylic dish에 $^{99m}Tc$ 37MBq을 넣고 5 cm, 10 cm, 20 cm, 30 cm, 40 cm 거리에서 각각 sensitivity ($cpm/{\mu}Ci$)를 측정 하였다. 그리고 Sensitivity 측정 결과를 바탕으로 기존의 일반적인 심근관류 SPECT를 기준으로 IQ SPECT protocol을 design 후 Anthropomorphic torso phantom을 사용하여 심근 관류 SPECT를 시행하여 비교하고, LEHR collimator의 영상 재구성에 따른 FWHM 비교를 위해 $^{99m}Tc$ Line source를 이용하여 기존의 심근 관류 SPECT의 재구성법인 FBP법과 IQ SPECT의 3D OSEM법에 대하여 알고리즘만 변화시켜 FWHM을 측정 비교하였다. Collimator senstivity 측정 결과 IQ SPECT의 multiple confocal collimator의 sensitivity가 LEHR collimator와 비교하여 30 cm 거리에서 sensitivity가 약 4배 정도 더 많아짐을 알 수 있었다. Sensitivity 결과를 바탕으로 IQ SPECT의 기하학적 특성에 맞게 심근 관류 SPECT protocol을 design 하여 phantom 실험을 시행한 결과 기존에 비해 검사시간을 1/4로 단축할 수 있었으며, LEHR collimator를 사용하여 SPECT 검사 후 FBP법과 3D OSEM 법의 재구성 알고리즘에 따른 FWHM 비교에서는 3D OSEM법에서 FWHM이 2배 정도 향상된 결과를 얻었다. 본 연구를 통해 IQ SPECT는 심근관류 SPECT에서 Multiple confocal collimator를 사용하여 감도를 향상시키고 심장에 특화된 기하학적인 영상 획득 방식과 영상 재구성 방법을 통하여 검사 시간을 단축하고 영상의 화질 개선에 도움을 준다. 이로 인해 환자는 전보다 더욱 편안하고 정확한 검사를 수행 할 수 있을 것이며, 추가적으로 더 많은 임상 자료를 통한 연구가 필요할 것이다.

  • PDF

CMOS 공정에 적합한 AlN 압전 마이크로 발전기의 제작 및 특성 (Fabrication of AlN piezoelectric micro power generator suitable with CMOS process and its characteristics)

  • 정귀상;이병철
    • 센서학회지
    • /
    • 제19권3호
    • /
    • pp.209-213
    • /
    • 2010
  • This paper describes the fabrication and characteristics of AlN piezoelectric MPG(micro power generator). The micro energy harvester was fabricated to convert ambient vibration energy to electrical power as a AlN piezoelectric cantilever with Si proof-mass. To be compatible with CMOS process, AlN thin film was grown at low temperature by RF magnetron sputtering and micro power generators were fabricated by MEMS technologies. X-ray diffraction pattern proved that the grown AlN film had highly(002) orientation with low value of FWHM(full width at the half maximum, $\theta=0.276^{\circ}$) in the rocking curve around(002) reflections. The implemented harvester showed the $198.5\;{\mu}m$ highest membrane displacement and generated 6.4 nW of electrical power to $80\;k{\Omega}$ resistive load with $22.6\;mV_{rms}$ voltage from 1.0 G acceleration at its resonant frequency of 389 Hz. From these results, the AlN piezoelectric MPG will be possible to suitable with the batch process and confirm the possibility for power supply in portable, mobile and wearable microsystems.

핵의학 계측기기 및 감마카메라의 정도관리 연구 (A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.103-112
    • /
    • 2001
  • 목적: 최근 국내의 핵의학 계측기기 및 감마카메라의 정도관리 수행현황을 파악하고, 핵의학 계측기기와 감마 카메라의 정도관리를 수행하고자 하였다. 방 법: 최근 국내의 핵의학 계측기기 및 감마 카메라의 정도관리 수행현황은 총 53개 병원을 대상으로 설문조사방법을 이용하여 수행하였다. 이들의 정도관리 연구는 Capintec의 CRC-15 기종의 dose calibrator와 Tc-99m 35.52 MBq을 사용하여 2분 간격으로 정밀도를 측정하였다. Nucleus사의 기종의 Thyroid Uptake system은 Tc-99m 5.14 MBq을 이용하여 1분 간격으로 10초동안 정밀도를 측정하였다. 지름이 15 cm이고 높이가 각각 12 cm, 30 cm인 원통형 팬텀과 TC-99m을 이용하여 저에너지 고해상도 조준기가 부착된 CeraSPECT$^{TM}$의 예민도를 측정하였다. CeraSPECT$^{TM}$와 일반 평면카메라와의 예민도에 대한 특성비교를 위하여 Varicam (Elscint Ltd, Israel) 감마 카메라로 영상을 얻었다. CeraSPECT$^{TM}$로 획득한 자료로 각 슬라이스에 대한 보정상수를 계산하였다. Elscint 사의 Varicam 감마 카메라의 정도관리를 위해 저에너지 고해상도 조준기를 부착하고 140 keV 중심20% 에너지창, 256$\times$256 또는 512$\times$512 메트릭스 크기를 이용하여 시스템의 평면 예민도, 균일도, 계수율 및 공기중과 산란매질에서의 공간 분해능을 측정하였다. 결 과: 핵의학 계측기기 및 감마 카메라의 정도관리 수행율은 dose calibrator와 well counter의 경우 매우 저조한 수행율을 나타내었으며 그 외 감마 카메라 등은 대체로 양호한 수행율을 나타내었다. dose calibrator의 정밀도 측정은 $\pm$1.4%(<$\pm$5%)의 결과를 얻었고, thyroid uptake system의 정밀도 측정은 chi^2=29.7(>16.92)의 결과를 얻었다. Varicam 감마 카메라의 경우 슬라이스들간에 전반적으로 균일한 민감도를 보여주었으나 CeraSPECT$^{TM}$ 의 경우는 위쪽과 아래쪽 부분의 슬라이스들은 민감도가 두드러지게 떨어져 있었고 팬텀의 중심부분 슬라이스들은 민감도가 매우 높은 것으로 나타났다. 계산한 보정 상수를 이용하여 CeraSPECT$^{TM}$로 얻은 환자 자료를 보정하였을 때 보정전에 비하여 전반적으로 균일한 영상을 얻을 수 있었다. 감마 카메라의 시스템 평면 예민도 측정 결과는 4.39 CPM/MBq 이었으며, 시스템 균일도는 첫 번째 검출기와 두번째 검출기가 각각 2.14%, 3.79%로 나타났다. 시스템 계수율 측정의 경우 입력 계수율 R_20%가 각각 102,407 counts/sec (head 1), 113,427 counts/sec (head 2)일 때 20% 계수율 손실이 발생했을 때의 측정된 계수율 C_20%는 각각 81,926 counts/sec (head 1), 90,741 counts/sec (head 2) 이었다. 공기 중에서의 시스템의 공간 분해능은 FWHM이 8.16 m, FWTM이 14.85 mm이었고, 산란매질에서는 시스템의 공간 분해능은 FWHM이 8.87 mm, FWTM이 18.87 mm이었다. 결 론: 정확하고 신뢰도 높은 검사를 위해 정도관리는 필수이며, 이에 대한 명확한 인식과 실질적인 수행이 반드시 뒤따라야 할 것으로 사료되었다

  • PDF

이중 모드 컴프턴 카메라의 측면 흡수부 제작을 위한 신호처리회로 개발 (Development of Signal Processing Circuit for Side-absorber of Dual-mode Compton Camera)

  • 서희;박진형;박종훈;김영수;김찬형;이주한;이춘식
    • Journal of Radiation Protection and Research
    • /
    • 제37권1호
    • /
    • pp.16-24
    • /
    • 2012
  • 본 연구에서는 이중 모드 컴프턴 카메라의 측면 흡수부 개발을 위해 CsI(Tl) 섬광체에 실리콘 광다이오드를 결합한 섬광 검출기를 제작하였고, 이를 위한 신호처리회로를 설계 및 제작하였다. 개발된 신호처리회로는 에너지를 결정하는 파트와 타이밍을 결정하는 파트로 구성되어 있으며, 트리거 신호를 발생시키기 위해 상승 에지 선별기 및 TTL-to-NIM 로직 변환기를 포함하도록 개발하였다. 검출기와 초단의 신호처리회로(front-end electronics, FEE)는 AC 커플링 구조로 구성하였다. FEE의 잡음 특성은 전체 시스템의 성능에 크게 기여하므로 설계 시 고려해야 할 몇 가지 조건들에 대해 논의하였다. 이후 제작된 감마선 검출 시스템의 에너지 분해능 및 시간 분해능을 결정하였다. 평가된 에너지 분해능은 662 keV 피크와 511 keV 피크에 대해서 각각 12.0% 및 15.6% FWHM이었다. 시간 분해능은 59.0 ns로 평가되었다. 본 연구를 통해 제작된 섬광 검출기 및 신호처리회로의 성능이 기대에 다소 미치지 못하므로 결론에서는 성능 향상을 위한 추가 연구 방향에 대해 논의하였다.