• Title/Summary/Keyword: electronic charge distribution

Search Result 117, Processing Time 0.028 seconds

Development of a stand-alone solar street light controller integrated (독립형 태양광 가로등 통합제어기 개발)

  • Kim, Hee-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.6
    • /
    • pp.641-647
    • /
    • 2014
  • Stand-alone PV systems and grid-connected distribution lines operating independently with out the advantage that it is simple, and construction equipment, but the advantage of less expensive MPPT converter and production, including the energy stored in the battery charging circuit and battery for managing circuitry is required. The use of existing alternative energy in the form of combined-cycle power generation than the one adopted by the form, but primarily solar / wind power system to optimize complex to design and improve the ability to install a battery that canrationalize the price you need an integrated control system be.

Measurement of Voltage Transfer Curve in AC PDP (AC-PDP특성평가를 위한 전압전달곡선 계측에 관한 연구)

  • 손진부;이성현;김동현;김영대;조정수;박정후
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.395-398
    • /
    • 1999
  • In ac PDP(plasma Display Panel), the discharge characteristics is very important to display clear images. In this paper, we have studied the measurement of voltage transfer curves which show the discharge characteristics in AC PDP. The change of the effective wall capacitance during a discharge is also studied. These depend on lateral spreading of charge distribution and the strength of the discharge. As a parameter of the frequency, we observed the effects of the frequency in voltage transfer curves and in effective wall capacitance changes. As frequency increases, minimum sustain voltage and firing voltage decrease. In upper region of gap voltage the chance of the effective wall capacitance is independent of frequency.

  • PDF

Theoretical studies on the stabilization and diffusion behaviors of helium impurities in 6H-SiC by DFT calculations

  • Obaid Obaidullah;RuiXuan Zhao;XiangCao Li;ChuBin Wan;TingTing Sui;Xin Ju
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2879-2888
    • /
    • 2023
  • In fusion environments, large scales of helium (He) atoms are produced by a radical transformation along with structural damage in structural materials, resulting in material swelling and degradation of physical properties. To understand its irradiation effects, this paper investigates the stability, electronic structure, energetics, charge density distribution, PDOS and TDOS, and diffusion processes of He impurities in 6HSiC materials. The formation energy indicates that a stable, favorable position for interstitial He is the HR site with the lowest energy of 2.40 eV. In terms of vacancy, the He atom initially prefers to substitute at pre-existing Si vacancy than C vacancy due to lower substitution energy. The minimum energy paths (MEPs) with migration energy barriers are also calculated for He impurity by interstitial and vacancy-mediated diffusion. Based on its calculated energy barriers, the most possible diffusion path includes the exchange of interstitial and vacancy sites with effective migration energies ranging from 0.101 eV to 1.0 eV. Our calculation provides a better understanding of the stabilization and diffusion behaviors of He impurities in 6H-SiC materials.

Implementation of a CAN Based Real-Time Simulator for FCHEV (하이브리드 연료전지 자동차의 CAN기반 실시간 시뮬레이터 구현)

  • Shim, Seong-Yong;Lee, Nam-Su;Ahn, Hyun-Sik;Kim, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.410-413
    • /
    • 2004
  • In this paper, a simulator system for Fuel Cell Hybrid Electric Vehicles(FCHEV) is implemented using DSP boards with CAN bus. The subsystems of a FCHEV i.e., the fuel cell system, the battery system, the vehicle dynamics with the transmission mechanism are coded into 3 DSP boards. The power distribution control algorithm and battery SOC control are also coded into a DSP board. The real-time monitoring program is also developed to examine the control performance of power control and SOC control algorithms.

  • PDF

Initial oxidation process on viinal Si(001) surface: ReaxFF based on molecular dynamics simulation

  • Yun, Gyeong-Han;Lee, Eung-Gwan;Choe, Hui-Chae;Hwang, Yu-Bin;Yun, Geun-Seop;Kim, Byeong-Hyeon;Jeong, Yong-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.300-300
    • /
    • 2011
  • Si oxidation is a key process in developing silicon devices, such as highly integrated metal-oxide-semiconductor (MOS) transistors and antireflection-coating (ARC) on solar cell substrate. Many experimental and theoritical studies have been carried out for elucidating oxidation processes and adsorption structure using ab initio total energy and electronic structure calcultaions. However, the initial oxidation processes at step edge on vicinal Si surface have not been studied using the ReaxFF reactive force field. In this work, strucutural change, charge distribution of oxidized Si throughout the depth from Si surface were observed during oxidation processes on vicinal Si(001) surface inclined by $10.5^{\circ}$ of miscut angle toward [100]. Adsorption energys of step edge and flat terrace were calculated to compare the oxidation reaction at step edge and flat terrace on Si surface.

  • PDF

Electrostatic Analysis and Protection of the Industrial Type Inkjet Plotter (산업용 잉크젯 플로터의 정전기 해석 및 차폐)

  • Choi, Geun-Soo;Baek, Soo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.159-167
    • /
    • 2006
  • According to industrial development, all fields using chemical instrument and material are generated an electrostatics. Electrostatic problems were very important part to all these components, moving system, printer, clothe machines etc. This paper was represented an analysis of electrostatic electrification by FEM (finite element method) of industrial type Inkjet plotter. Here electrostatics distribution analysis is accomplished by Maxwell-2D. We are showed an electrostatics generation source by rubbing and meager profits of electric charge. It know electronic values with each system position by experiment. These are decreased through earth and electricity shielding. Therefore this paper is proved by the simulation and experiment result.

Protection and Electrostatic Analysis of the Industrial Type Inkjet Plotter using FEM (유한요소법을 이용한 산업용 잉크젯 플로터의 정전기 해석과 대책)

  • Yoon, S.Y.;Choi, G.S.;Kim, Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1496-1499
    • /
    • 2005
  • This paper was represented an electrostatics distribution analysis using FEM(finite element method) with industrial type Inkjet plotter. Here, we know electronic value with each system position by experiment. these were decreased by discharge through earth and electricity shielding. According to industrial development, all fields using chemical instrument and material are generated an electrostatics. Based on these, the big large position of electrostatics was obtained metal base of controller, nonconductor fiber between two rubber roller, head controller by moving roller etc., Therefore these were showed an electrostatics generation source and by rubbing and meager profits electric charge.

  • PDF

Utilization of Evidence-Based Clinical Nursing Practice Guidelines in Tertiary Hospitals and General Hospitals (상급종합병원과 종합병원의 근거기반 임상간호실무지침의 활용도)

  • Eun, Young;Jeon, Mi Yang;Gu, Mee Ock;Cho, Young Ae;Kim, Jung Yeon;Kwon, Jeong Soon;Kim, Kyeong Sug
    • Journal of Korean Clinical Nursing Research
    • /
    • v.27 no.3
    • /
    • pp.233-244
    • /
    • 2021
  • Purpose: The purpose of this study was to investigate the actual utilization of clinical practice guidelines developed by Hospital Nurses Association. Methods: The subjects were 70 nurses who were in charge of guideline distributions in 70 advanced general hospital and general hospitals with 500 beds or more nationwide. Data were collected between June and August, 2020 by mail (return rate: 88.6%). Data were analyzed using descriptive statistics, t-test, and ANOVA with SPSS/WIN 24.0. Results: Among the clinical practice guidelines developed by Hospital Nurses Association, 72.9~90.1% were placed with book and electronic file in nursing department and 24.3~35.8% were placed with book and electronic file in each nursing unit at hospital. The average number of utilized clinical practice guidelines were 3.96±3.88, and average score of guideline utilization was score 2.85±0.79 which means 'use sometimes'. Conclusion: To improve the distribution and utilization of the clinical practice guidelines, it is necessary to enhance the recognition of values of evidence based nursing practice targeting head of nursing department and to stimulate the distribution and utilization of the clinical practice guidelines using diverse education programs for staff nurses.

Efficient Signal Integrity Verification in Complicated Multi-Layer VLSI Interconnects (복잡한 다층 VLSI 배선구조에서의 효율적인 신호 무결성 검증 방법)

  • Jin, U-Jin;Eo, Yun-Seon;Sim, Jong-In
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.3
    • /
    • pp.73-84
    • /
    • 2002
  • Fast and accurate new capacitance determination methodology for non-uniform complicated multi-layer VLSI interconnects is presented. Since a capacitance determination of intricate multi-layer interconnects using 3-dimensional field-solver is not practical, quasi-3-dimensional methodology is presented. Interconnects with discontinuity (i.e., bend structure and different spacing between lines, etc.) are partitioned. Then, each partial capacitance of divided parts is extracted by using 2-dimensional extraction methodology. For a multi-layer interconnects with shielding layer, the system can be simplified by investigating a distribution of charge in it. Thereby, quasi-3-dimensional capacitance for multi-layer interconnects can be determined by combining solid-ground based 2-dimensional capacitance and shielding effect which is independently determined with layout dimensions. This methodology for complicated multi-layer interconnects is more accurate and cost-efficient than conventional 3-dimensional methodology It is shown that the quasi-3-dimensional capacitance methodology has excellent agreement with 3-dimensional field- solver-based results within 5% error.

Evaluation of Material Characteristics of Suspension-Type Porcelain Insulators for 154 KV Power Transmission Lines

  • Choi, In-Hyuk;Park, Joon-Young;Kim, Tae-gyun;Yoon, Yong-Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.4
    • /
    • pp.207-210
    • /
    • 2017
  • The suspension arrangement of insulators provides flexibility and assists in power transmission in transmission lines. The performance of the insulator string is strongly influenced by the environmental conditions to which it is exposed, its shape and the inherent material properties of suspension-type insulators. The suspension-type insulators are mostly made from glass, porcelain and ceramic material due to their high resistivity. Irregularity in charge distribution throughout the porcelain insulator may lead to accelerated aging and electrical breakdown. A very high and steep lightning impulse voltage may also cause breakdown of suspension-type insulators. We investigated various material characteristics such as alumina addition, surface morphology, x-ray diffraction pattern and relative density of suspension porcelain insulators manufactured in 1989 (36,000 lbs.), 1995 (36,000 lbs.) and 2001 (36,000 lbs.) by the KRI Company for use in 154 kV high power transmission lines. We compared the material characteristics of these porcelain insulators with that of the top-of-the-line porcelain insulators (36,000 lbs.) manufactured by the NGK Company in 2000. These suspension-type porcelain insulators were exposed to arc and flashover tests to examine their electrical and mechanical strength. It was noted that alumina addition (17 wt.%) for K-2001 was one of the major contributors to the enhancement of the performance of the porcelain insulators and to their ability to withstand very high current generation during the arc test. The porcelain insulators manufactured during 2001 also showed the highest relative density of 95.8% as compared to the other insulators manufactured in 1989 and 1995 respectively 94.2% and 91.5%. We also discuss reports of various failure modes of suspension-type porcelain insulators.