• Title/Summary/Keyword: electromagnetic shielding

Search Result 356, Processing Time 0.027 seconds

Preparation of Amine-functionalized Graphene Fiber and Its Application (아민 분자로 개질된 그래핀 섬유의 제조 및 응용)

  • Lee, Wonoh;Yoon, Sang Su;Um, Moon-Kwang;Lee, Jea Uk
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.265-269
    • /
    • 2015
  • Development of simple and efficient method for large-scale production of mechanically strong and electrically conductive graphene fiber is highly desirable for practical applications, such as fiber-reinforced composites, wearable electronics, and electromagnetic irradiation shielding. Here, we present a facile approach for the preparation of amine-functionalized graphene fibers by simple wet-spinning of diamine-functionalized graphene oxide (GO-$NH_2$), which is used because of its synthetic convenience, good dispersity, and scalable production with low cost. The amine-functionalized graphene fiber shows high electrical and mechanical properties compared to pristine graphene oxide fiber due to the electrostatic interaction between amine groups and electronegative functional groups of graphene oxide.

Compensation Method of Parameters to Evaluate a Sheilding Coefficient of Electromagnetic Induction Voltage (전자유도전압 차폐계수 산정을 위한 파라미터 보정 방법)

  • Lee, Sangmu;Choi, Mun Hwan;Cho, Pyung-dong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.503-506
    • /
    • 2013
  • The shielding coefficient of a conductive length structure is calculated by a ratio of induced voltage with that structure to without that structure. The environments are different between with a structure and without a structure. Beside the corresponding structure, all the parameters related to induced voltage should be normalized to a presumable same environment conditions. Basically each parameter must be compensated, which is a bottom-up type method. In this case, some parameter is not possible to be so because of its unknowing function. Then as a calculated voltage already has all characteristics of parameters, seeking a ratio of calculated induction voltages themselves will include the compensation of all parameters automatically. This is a top-down method.

  • PDF

Evaluation of Flow Characteristics in Water Supply Pipes Shielding Electromagnetic Pulse of 100 dB with Concentric and Eccentric Reducers (Concentric Reducer와 Eccentric Reducer를 사용한 EMP 차폐 100dB급 급수관의 유동특성 평가)

  • Pang, Seung-Ki;Ahn, Hye-Rin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, the flow characteristics of water in the water supply pipes of a WBC array were evaluated. We simulated the flow velocities and pressures for a standard pipe, an expansion pipe with a concentric reducer, and an expansion pipe with an eccentric reducer using computational fluid dynamics. In the case of the standard pipe, when the inlet flow velocities were 0.5 m/s and 2.0 m/s, the maximum flow velocities at the center of the WBC array were 0.54 m/s and 2.74 m/s, respectively, which were the greatest values among those of all the pipe models considered. In the case of the expansion pipe, the maximum flow velocities at the center of the WBC array were almost the same under the same conditions regardless of the type of reducer. The pressure losses in the pipe due to the concentric and eccentric reducers were found to be (165.09 ${\times}$ inlet $velocity^{1.6677}$) and (210.98 ${\times}$ inlet $velocity^{1.6478}$), respectively. The coefficient of determination at this time was greater than 0.99 and was the same for both the models. As a simulation result, it was found that in order to reduce the pressure loss when pipe with WBC array is connected with a conventional pipe, diameter of the pipe with WBC array at that section should be enlarged by one step, and then connected to the conventional pipe with a concentric reducer.

The Development of Lightning Outage Rate Calculation Program (송전선로 뇌 사고율 예측계산 프로그램 개발)

  • Kang, Yeon-Woog;Shim, Eung-Bo;Kweon, Dong-Jin;Kwak, Ju-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.118-125
    • /
    • 2008
  • The outages of transmission lines give big damages to the industrial world Lightning outages occupy above 50[%] among the outages of transmission lines. To decrease the lightning outage rates, it is necessary to try countermeasures considering economical points. For the lightning protection of power transmission lines, it is very important to accurately predict the lightning outage rate because the reliability criterion for transmission line is normally specified as the number of flashovers per 100[km] per year. The phenomenon of an insulator flashover by a lightning stroke is a very complex electromagnetic event. And to calculate the lightning outage rates of transmission lines, so many calculation should be repeated because there are many overhead lines and power lines. Therefore it is necessary to develope a program for it. In this paper, we briefly introduce the basic concept for lightning outage calculation algorithm and the program.

Effect of Reductants and their Properties of Electric Resistivity on the Preparation of Ag coated Cu Powders by Chemical Reduction Method (화학환원법을 이용한 은 코팅 구리 분말 제조 시 환원제의 영향 및 전기비저항 특성)

  • Ahn, Jong-Gwan;Yoon, Chi-Ho;Kim, Dong-Jin;Cho, Sung-Wook;Park, Je-Shin
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.12
    • /
    • pp.1097-1102
    • /
    • 2010
  • Silver coated copper powders were prepared by a chemical reduction method with controlling the deposition process variables such as the feeding rate of the silver ionic solution and concentration of the reductants at room temperature. The characteristics of the products were evaluated by scanning electron microscope (SEM), X-ray diffractometer (XRD), atomic absorption spectrophotometer (AA) and a 4 probe resistivity measurement system. The optimum condition of the preparation of Ag coated Cu powders was at 0.05 M of potassium sodium tartrate and 2 ml/min of the feeding rate of the silver ionic solution. Our method successfully produced dense, uniform, and well-dispersed Ag coated Cu powder of $2{\sim}2.5{\mu}m$ witha silver layer of 100~200 nm. Additionally, we found that thespecific resistivity of the 30 wt.% Ag coated Cu powder was similar to that of pure silver, so that the composite powder could be used as an alternative electromagnetic shielding material for silver.

Effect of Multi-walled Carbon Nanotube Dispersion on the Electrical, Morphological and Rheological Properties of Polycarbonate/Multi-walled Carbon Nanotube Composites

  • Han, Mi-Sun;Lee, Yun-Kyun;Kim, Woo-Nyon;Lee, Heon-Sang;Joo, Jin-Soo;Park, Min;Lee, Hyun-Jung;Park, Chong-Rae
    • Macromolecular Research
    • /
    • v.17 no.11
    • /
    • pp.863-869
    • /
    • 2009
  • The effect of a multiwalled carbon nanotube (MWCNT) dispersion on the electrical, morphological and rheological properties of polycarbonate (PC)/MWCNT composites was investigated, with and without pretreating the MWCNTs with hydrogen peroxide oxidation and lyophilization. The resulting PC/treated MWCNT composites showed higher electrical conductivity than the PC/untreated MWCNT composites. The morphological behavior indicated the treated composites to have greater dispersion of MWCNTs in the PC matrix. In addition, the electromagnetic interference shielding efficiency (EMI SE) of the treated composites was higher than that of the untreated ones. Rheological studies of the composites showed that the complex viscosity of the treated composites was higher than the untreated ones due to increased dispersion of the MWCNTs in the PC matrix, which is consistent with the electrical conductivity, EMI SE and morphological studies of the treated composites. The latter results suggested that the increased electrical conductivity and EMI SE of the treated composites were mainly due to the increased dispersion of MWCNTs in the PC matrix.

Model Experiments and Behavior Analyses of The Tunnel Support Using TDR Sensor (TDR센서를 이용한 터널 지보재의 모형 실험과 거동해석)

  • Park, Min-Cheol;Han, Heui-Soo;Cho, Jae-Ho;Yang, Nam-Young
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.9
    • /
    • pp.35-45
    • /
    • 2011
  • This paper is to analyze the behaviors of tunnel support by TDR(Time Domain Reflectometry) sensor using electrical pulse. To analysis the behaviors of tunnel support, Copper tape as sensing materials was studied for on-site installation. Copper tape to the top of the glass tape, foam tape, and shielding the lower part was used electromagnetic shield sheet. For a high sensitivity to load and fill out the measurement noise emissions has been developed for the production of materials. This sensing material through the tunnel model tests for the change by surcharge load in TDR data were analyzed. Varing stiffness and support of conditions were determined the change of TDR data through PVC pipe tunnel section model tests. By comparing TDR data and finite element analysis, the behaviors of the tunnel support materials were analyzed qualitatively.

Block Media Communication System for Implementation of a Communication Network in Welding Workplaces (용접 작업장 통신네트워크 구축을 위한 블록매체통신시스템)

  • Kim, Hyun Sik;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.4
    • /
    • pp.556-561
    • /
    • 2022
  • In this paper, we present a block media communication (BMC) system which employs powerline communication to the equipments used in the welding process for ship-assembly and uses metal block as a communication medium. Inductive couplers are installed on digital feeder and pin jig. Information signal is added to the current generated by the welding gun, and applied to the block. When the welding operation starts, information generated in the field is transmitted to the monitoring server in real-time. The field test on the BMC system confirms that the transmitted data are correctly received at the server. Since the proposed system can be built without any changes to the existing welding process, it is helpful to increase competitiveness of the shipbuilding industry through smart factory of shipyards. It is also possible to quickly respond to emergency situations that may occur to workers in an electromagnetic wave shielding environment or a closed space, the effect of preventing industrial accidents will be great.

Technical Trends of Ti3C2TX MXene-based Flexible Electrodes (Ti3C2TX MXene 기반 유연 전극 기술 개발 동향)

  • Choi, Su Bin;Meena, Jagan Singh;Kim, Jong-Woong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.1
    • /
    • pp.17-33
    • /
    • 2022
  • Ti3C2TX MXene, first reported by Naguib et al. in 2011, has attracted tremendous attention due to its excellent hydrophilicity, electrical conductivity, and mechanical/chemical stability. Since MXene is a two-dimensional material with a thickness of few nanometers, which ensure its flexibility. In last few years, due to these properties many researchers used Ti3C2TX MXene into various fields such as flexible smart sensors, energy harvesting/storage devices, supercapacitors and electromagnetic interference shielding systems. In this review article, we have briefly discussed the various synthesis processes and characteristics of Ti3C2TX MXene. Moreover, we reviewed the latest development of Ti3C2TX MXene as flexible electrode material to be used into different applications.

Analysis and Improvement of False Alarm Phenomenon of Emergency Hydraulic Warning Light by Shielded RF Radiation Signal (RF 방사 신호 차폐를 통한 비상 유압경고등의 비정상 점등 현상의 원인분석 및 개선)

  • Jung-Hyuk Kwon;Gyeong-Nam Kim;Byeong-Kwon Jeon;Wang-Sang Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.68-78
    • /
    • 2023
  • In this paper, improvement measures were studied for false alarm (abnormal lighting) of emergency hydraulic warning light due to RF radiation signals in aircraft. When the warning lamp of the emergency hydraulic system is lit during flight due to electromagnetic interference caused by RF radiation signals, it affects flight mission and safety which can result in efficiency degradation and maintenance of flight mission. For false alarm of emergency hydraulic warning light, root cause analysis and troubleshooting were carried out. By shielding a composite strip under fuselage of the aircraft located in the path of the RF radiation signal, the RF radiation signal flowing into the emergency hydraulic indicator was blocked. Results of applying the improvement method through ground and flight monitoring were also described.