• Title/Summary/Keyword: electrical performance

Search Result 15,413, Processing Time 0.04 seconds

A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test (진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구)

  • Lee, Ki-Seon;Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

A Study on the Evaluation Algorithm for Performance Improvement in PV Modules

  • Kim, Byung-ki;Choi, Sung-sik;Wang, Jong-yong;Oh, Seung-Taek;Rho, Dae-seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1356-1362
    • /
    • 2015
  • The location of PV systems in distribution system has been increased as one of countermeasure for global environmental issues. As the operation efficiency of PV systems is getting decreased year by year due to the aging phenomenon and maintenance problems, the optimal algorithm for state diagnosis in PV systems is required in order to improve operation performance in PV systems. The existing output prediction algorithms considering various parameters and conditions of PV modules could have complicated calculation process and then their results may have a possibility of significant prediction error. To solve these problems, this paper proposes an optimal prediction algorithm of PV system by using least square methods of linear regression analysis. And also, this paper presents a performance evaluation algorithm in PV modules based on the proposed optimal prediction algorithm of PV system. The simulation results show that the proposed algorithm is a practical tool of the state diagnosis for performance improvement in PV systems.

A supervised-learning-based spatial performance prediction framework for heterogeneous communication networks

  • Mukherjee, Shubhabrata;Choi, Taesang;Islam, Md Tajul;Choi, Baek-Young;Beard, Cory;Won, Seuck Ho;Song, Sejun
    • ETRI Journal
    • /
    • v.42 no.5
    • /
    • pp.686-699
    • /
    • 2020
  • In this paper, we propose a supervised-learning-based spatial performance prediction (SLPP) framework for next-generation heterogeneous communication networks (HCNs). Adaptive asset placement, dynamic resource allocation, and load balancing are critical network functions in an HCN to ensure seamless network management and enhance service quality. Although many existing systems use measurement data to react to network performance changes, it is highly beneficial to perform accurate performance prediction for different systems to support various network functions. Recent advancements in complex statistical algorithms and computational efficiency have made machine-learning ubiquitous for accurate data-based prediction. A robust network performance prediction framework for optimizing performance and resource utilization through a linear discriminant analysis-based prediction approach has been proposed in this paper. Comparison results with different machine-learning techniques on real-world data demonstrate that SLPP provides superior accuracy and computational efficiency for both stationary and mobile user conditions.

Fuzzy Control of Discharge Pulse Duration for Electrical Discharge Machinery (방전가공기의 방전 펄스 시간의 퍼지제어)

  • Lee, Je-Hie;Park, Ho-Joon;Yang, Jik-Hyun;Huh, Uk-Youl;Lee, Sun-Woo;An, Sung-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1167-1169
    • /
    • 1996
  • As electrical discharge machinery(EDM) is industrial process which is manufactured by discharge energy, by producing discharge, EDM process finished material at the little micrometer air gap. Especially, EDM is used for the characteristic of heat-resisting material, it puts to use air-space industrial element, confusing shaping material such as jet engine, rocket elements. Working performance. is changed by environment of working, discharge current voltage and duration of discharge pulse. Evaluation of performance working is work speed, clearance smoothing of product surface, wasting of pole. In this paper, this machine is compensated by adaptive controller which corrects the weak points of classical machine which is observed and operated working condition by user in hands. The previous purpose is main object in this thesis. The adaptive controller automatically detect abnormal condition and working conditions. To improve performance, surface smoothing and working speed, the adaptive controller uses fuzzy control strategy. To evaluate performance, this controller is implemented by microprocessor i80c196 and is applied real experimental machine.

  • PDF

The Performance Improvement of Lightning Arrester Leakage Current Measuring Device for GIS (GIS용 피뢰기 누설전류 측정장치 성능개선)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1726-1731
    • /
    • 2014
  • This paper shows the developed new lightning arrester LCM (Leakage Current Measuring device) which is important element of GIS (Gas Insulated Switchgear) Preventive & Diagnostic system and verify its performance though strengthened test standards. The existing lightning arrester LCM was modified to solve measuring errors which happened frequently. At first, we explained the principle of measuring leakage current. Through analyzing some problems which the existing LCM have. we got some improvable items. For the performance verification of the improved LCM, we manufactured prototype LCM which is applied some improvable items such as improving LCM circuit, adding protection circuit, optimizing inner structure of LCM and changing ground design. After then we carried out the performance test. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria. Also, we confirmed the performance of the improved LCM installed & being operated at G Substation through the immunity test against the normal noise and open/close surge etc.

High Performance Controller of Induction Motor with Hybrid Artificial Intelligent Control (하이브리드 인공지능 제어기에 의한 유도전동기의 고성능 제어)

  • Park, Byung-Sang;Choi, Jung-Sik;Ko, Jae-Sub;Lee, Jung-Ho;Kim, Jong-Kwan;Park, Ki-Tae;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.737-738
    • /
    • 2006
  • This paper is proposed hybrid artificial intelligent controller for high performance of induction motor drive. The design of this algorithm based on fuzzy-neural network controller that is implemented using fuzzy control and neural network. The control performance of the hybrid artificial intelligent controller is evaluated by analysis for various operating conditions. The results of experiment prove that the proposed control system has strong high performance and robustness to parameter variation, and steady-state accuracy and transient response.

  • PDF

Composited Conductive Materials for Enhancing the Ultrafast Performance for Anode in Lithium-Ion Battery (리튬이온전지 음극의 고속 성능 향상을 위한 도전재 복합화)

  • Ki-Wook, Sung;Hyo-Jin, Ahn
    • Korean Journal of Materials Research
    • /
    • v.32 no.11
    • /
    • pp.474-480
    • /
    • 2022
  • Lithium-ion batteries (LIBs) are powerful energy storage devices with several advantages, including high energy density, large voltage window, high cycling stability, and eco-friendliness. However, demand for ultrafast charge/discharge performance is increasing, and many improvements are needed in the electrode which contains the carbon-based active material. Among LIB electrode components, the conductive additive plays an important role, connecting the active materials and enhancing charge transfer within the electrode. This impacts electrical and ionic conductivity, electrical resistance, and the density of the electrode. Therefore, to increase ultrafast cycling performance by enhancing the electrical conductivity and density of the electrode, we complexed Ketjen black and graphene and applied conductive agents. This electrode, with the composite conductive additives, exhibited high electrical conductivity (12.11 S/cm), excellent high-rate performance (28.6 mAh/g at current density of 3,000 mA/g), and great long-term cycling stability at high current density (88.7 % after 500 cycles at current density of 3,000 mA/g). This excellent high-rate performance with cycling stability is attributed to the increased electrical conductivity, due to the increased amount of graphene, which has high intrinsic electrical conductivity, and the high density of the electrode.

Hybrid Filter Design for a Nonlinear System with Glint Noise (글린트잡음을 갖는 비선형 시스템에 대한 하이브리드 필터 설계)

  • Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Ji-Bae;Shin, Jong-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.26-29
    • /
    • 2001
  • In a target tracking problem the radar glint noise has non-Gaussian heavy-tailed distribution and will seriously affect the target tracking performance. In most nonlinear situations an Extended Robust Kalman Filter(ERKF) can yield acceptable performance as long as the noises are white Gaussian. However, an Extended Robust $H_{\infty}$ Filter (ERHF) can yield acceptable performance when the noises are Laplacian. In this paper, we use the Interacting Multiple Model(IMM) estimator for the problem of target tracking with glint noise. In the IMM method, two filters(ERKF and ERHF) are used in parallel to estimate the state. Computer simulations of a real target tracking shows that hybrid filter used the IMM algorithm has superior performance than a single type filter.

  • PDF

Transient Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motors (단상 영구자석형 유도동기기의 과도상태해석)

  • Lee, Sun-Kwon;Kang, Gyu-Hong;Hong, Jung-Pyo;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.147-149
    • /
    • 2001
  • The single-phase line-start permanent magnet motor has been shown to be capable of very desirable steady state performance, but known to have undesirable starting performance. This is because magnetic braking torque. So, it is very important to predict starting performance accurately when designing the line-start motors. In this paper, starting performance was calculated by combination of d-q axis voltage equations and mechanical dynamic equations. D-q axis voltage components were derived by winding angle and turns ratio transformations.

  • PDF

Performance Assessment of SFM Pulse in Reverberation Environment

  • Shin Seung-Je;Lee Hyung-Soo;Bae Eun-Hyon;Park Do-Hyun;Lee Kyun-Kyung
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.254-257
    • /
    • 2004
  • In shallow water, the performance of the operating active sonar systems is usually limited by reverberation. One of the measure to overcome the negative effect of reverberation is of selecting an adequate transmission pulse. SFM(Sinusoidal Frequency Modulation) pulse has been received a considerable attention as a candidate for suppressing the reverberation effect. In this paper, we analyze the detection performance of SFM pulse with respect to modulation frequency and bandwidth. To conduct the analysis. we synthesize the signal at the receiver considering. the transmitter. the receiver, and the propagation medium characteristcs. The simulations provide the optimum modulation frequency and bandwidth under the given situation.

  • PDF