• 제목/요약/키워드: electric railroad catenary

검색결과 67건 처리시간 0.022초

교류 급전시스템 보호를 위한 전차선로 고장특성 분석 (Analysis of fault characteristics in Catenary system for protection of AC feeding system)

  • 정호성;박영;김주락;권삼영;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1089-1090
    • /
    • 2006
  • This paper analyzes impedance convergence characteristics and harmonics of electric locomotives operation and fault condition. To simulate the various fault and operation condition, AT feeding system and various locomotives are modeled using PSCAD/EMTDC. Analysis shows that impedance are converged into protection area in the case of short fault between catenary and rail or catenary and feeder line but in the case of disconnection fault, impedance is rater bigger so protective relay can't detect the fault. Therefore more analysis of overload and high impedance fault caused disconnection fault is needed.

  • PDF

고속철도 전차선로 드로퍼 클램프 내구성 기준 정립에 관한 연구 (A Study on Durability Standard Specification of the Dropper Clamp of Catenary for High Speed Railway)

  • 오완식;양인동;박병곤;홍석진;김성철
    • 전기학회논문지
    • /
    • 제66권9호
    • /
    • pp.1431-1436
    • /
    • 2017
  • The high-speed railway of catenary system, supplies a stable electric power supply to the train by satisfying the special conditions between pantograph and trolley wire, which operates more than 250km/h mutually sliding and feeding electric lines. According to Korean Railway Standard KRS PW 0026-13 (R), the standard for the grip strength of the dropper clamp in conventional line is established, but the high-speed railway line is not yet. When the grip strength of the dropper clamp is detached from the catenary line of the high-speed railway line, various problems may occur, such as damage to the pantograph due to the collision and arcing. In this paper, it is expected to be used as a basic data for establishing the durability criteria of the high-speed railway dropper clamp by verifying the dropper clamp on the Gyeong-bu and Honam high-speed line.

조가선 전류 검측 시스템의 활용기술 연구 - 고속선 경부2단계 시험결과를 중심으로 - (Utilizing Technology in Measurement System for Catenary Current: - Focusing on Testing Results for Kyoungbu High-speed Line in Korea -)

  • 박영;정호성;이기원
    • 전기학회논문지
    • /
    • 제62권10호
    • /
    • pp.1465-1469
    • /
    • 2013
  • The resent developed high speed train called HEMU-430X (Highspeed Electric Multiple Unit - 430km/h eXperiment) recorded a 421.4 km/h in Kyoungbu high speed line in Korea. A verity of measurement systems are used to check the performance between pantograph and catenary system. An innovative measurement system is adopted to check the current of catenary wire in the track side during HEMU-430X test running. This paper presents the measurement results of catenary current in kyoungbu high-speed line and describe its utilizing technology in the experimental results of catenary current. In order to analyze field testing results, the current ratio between contact and catenary current have been analyzed by means of Carson-Pollaczek equation. And the current wave forms between catenary and contact wire are presented based on the simulation results.

전차선로용 곡선당김금구의 성능향상에 관한 연구 (A Study on the Performance Improvement of Pull-off Fitting for Catenary)

  • 김찬영;류근배;정용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1417-1420
    • /
    • 2001
  • This paper presents the results of materials and mechanical analyses and performance improvement of pull-off fitting used for catenary. The pull-off fitting is supporting the trolley wire which supplies the electricity. However, the pull-off fitting is repeatedly suffered by the mechanical stresses which produce cracks in the swivel clip, resulting in interruption of an electric car. The characteristic analyses of the swivel clip were performed and the improved swivel clip was suggested.

  • PDF

전차선 절연구분장치 절연재의 이상마모 대책 (Countermeasures to Irregulor Abrasion of Section Insulators for Electric Railroad Catenary)

  • 최규형
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.87-94
    • /
    • 2002
  • 전원위상이 다른 전차선 구간을 전기적으로 구분하기 위한 절연구분장치 중에서 특히, 지하구간에 설치된 교/직 절연구분장치는 강체가선 및 조가선 가선이 혼합된 특수한 가선구조로 되어 있어, 전동차 팬터그래프와 습동하는 절연재에 불규칙한 파상마모 현상이 발생한다. 본 논문에서는, 이와 같은 절연구분장치 절연재의 마모현상에 대하여, 현장 측정을 통하여 마모정도 및 마모형태를 조사하고, 전기철도 운행 및 유지보수에 미치는 영향을 분석하였다. 그리고. 절연재 이상마모에 영향을 미칠 수 있는 요인으로서, 절연구분장치의 설치높이 편차와 팬터그래프 압상력에 대응한 절연구분장치의 변위에 대한 실험적 분석을 수행하였고, 절연구분장치와 팬터그래프간에 작용하는 접촉력에 대한 이론적 분석을 통하여 그 발생원인을 규명하였다. 이와 같은 실험적, 이론적 분석을 토대로, 효과적인 절연구분장치 개량방법을 제시하였다.

9도체 전기철도 모델링을 이용한 고장점 표정 방안 연구 (A Study for Fault Location Scheme Using the 9-Conductor Modeling of Korean Electric Railway System)

  • 이한상;이장무;이한민;장길수;창상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.411-413
    • /
    • 2006
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because there is a long distance, 40 km or longer, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, the catenary system must be modeled exactly to analyze fault current magnitude and fault location. In this paper, before suggestion for the novel scheme of fault location, a 9-conductor modeling technique that includes boost wires and impedance bonds is introduced, based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and suggest a powerful model for fault analysis on electric railway systems.

  • PDF

활차식 자동장력조정장치 성능진단 및 유지보수 개선에 관한 연구 (A Study on Performance Diagnosis of the Pulley Type Automatic Tensioning Device and Improvement of Maintenance)

  • 박현;노영환
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1103-1107
    • /
    • 2016
  • The automatic tensioning device of the catenary system constantly maintains the tension of the trolley wire by absorbing the variations due to the elasticity of the line caused by temperature variation. The tension plays an important role in affecting the electric motorcar operation directly. This paper suggests the methodology of the life cycle extension and the maintenance of the automatic tensioning device by means of performance diagnosis of the pulley type automatic tensioning device which has been commonly used for the electric railway system. Through conducting performance diagnosis and comparative test for the wornout pulley type automatic tensioning device by replacing the components such as the bearing and the bearing shaft without replacing all the assembly, the tensioning device is analyzed whether it is properly functioned. Provided that the maintenance regulation is reinforced so as to implement the bearing replacement through periodical precise inspection along with random check-up inspection which is now carried out by the operating organizations, it is ensured that the life cycle extension and the reduction of maintenance cost of the tensioning device could be achieved.

전차선로시스템의 순환전류에 대한 안정성 향상에 관한 고찰 (Considerations in the reliability improvement against Circulation Current in the Catenary System for Electirc Railway of Korea)

  • 김인철;강승욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.24-26
    • /
    • 2006
  • In these days, Korea Railway apply simple catenary system to general lines and high speed lines of Korea Electric Railway. Circulation Current in catenary system frequently bring undesirable consequences. Namely, the Connector wire has many problems according to a flow of excessive circulation (or traction current) and a sudden rise of temperature on catenary when electric car or locomotive is running in high speed. The occurrence of events by the load increasement do considerable damages to peoples, organizations and systems. In this paper, we proposed the improved changes on the catenary system of a improvement and change of a messenger wire protector, improvement of connector wire,s institution angle and of a replacement the connector wire with a dropper. A case of Circulation Current continually has broken out in Yongdungpo Electric Office's own bailiwick. By or through the medium of these obstacles, we have further use of many studies and considering countermeasures. Therefore, we have to deal with the question in design and execution of catenary system for High Speed Railway because we will spend a lot of time and more money for maintenance than for construction of that.

  • PDF

전기철도 전차선로 지지애자의 염해지역 열화특성 사례 연구 (A Case Study of Degradation Characteristics for Rod-Insulator on Catenary System in Electric Railway)

  • 정호성;박영
    • 한국전기전자재료학회논문지
    • /
    • 제32권4호
    • /
    • pp.263-266
    • /
    • 2019
  • In the Airport Railroad, the Yeongjong Bridge has a length of 4,420 m and connects Yeongjong Island with the mainland of Incheon City. The bridge is a two-level structure, consisting of a six-lane road at the upper level and a combination of a road and railroad at the lower level. The environmental conditions for the electric railway come mainly from the salt injury area and a heavy industry zone, and the maintenance cycles are determined differently depending on these conditions. This study analyzed the deterioration characteristics of long rod insulators produced with a movable ceramic bracket and polymer materials in the Yeongjong Bridge section of the Airport Railway operating in the salt injury area according to the material characteristics. Comparison of the corona measurements when the insulators were cleaned at the same time showed that the polymer insulator had a higher insulation performance than the ceramic insulator.

무선기반 전차선로의 해빙 감지시스템 구현 (An Implementation of Wireless Based Sensing System for Catenary Deicing)

  • 김주욱;나경민;박영
    • 한국전기전자재료학회논문지
    • /
    • 제32권6호
    • /
    • pp.512-515
    • /
    • 2019
  • Overhead contact systems (OCS) consist of contact and messenger wires, in which the contact wire supplies electric energy to the railway vehicle by contacting a pantograph. However, this mechanical contact is interrupted during frosts or temperatures below $0^{\circ}C$ in the winter. In these conditions, railway vehicle accidents can occur during operation because of the low energy efficiency that results from the increase in the arcing between the contact wire and pantograph. Therefore, the detection of frost or freezing temperatures is necessary to maintain the stable operation of these trains. In this study, we proposed the development of a frost or freezing condition monitoring system on the OCSs that utilizes wireless communication.