Browse > Article
http://dx.doi.org/10.5207/JIEIE.2002.16.6.087

Countermeasures to Irregulor Abrasion of Section Insulators for Electric Railroad Catenary  

최규형 (한국철도기술연구원)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.16, no.6, 2002 , pp. 87-94 More about this Journal
Abstract
As a section insulator dividing the electric railroad catenaries with different phases, the AC/DC section insulator which divides AC and DC railroad catenary have the complex structure, and suffer irregular abrasion on the surface or insulator rods when it is installed at the underground railroad. This paper intended as an investigation of the irregular abrasion of section insulators, provides the field measurements of abrasion level along insulator length and the abrasion patterns. The height variation of insulator parts and the balding length of insulators against pantograph's contact force are analysed experimentally, and the irregular abrasion mechanism is clarified with the help of theoretical analysis on the interaction between pantographs and section insulators. On the basis of experimental and theoretical analysis, the countermeasures to reduce the irregular abrasion are provided too.
Keywords
electric railroad catenary; section insulator; FRP insulator; irregular abrasion; pantograph;
Citations & Related Records
연도 인용수 순위
  • Reference
1 M. Shimizu 외 2인, “Development of the methods of improving the contact loss between overhead rigid conductor line and pantograph”, RTRI Report Vol. 16, No.6, pp. 33-38, 2002. 6,
2 T.Gobida, “고속열차대응 가선재료설비의 현상”, 철도와 전기기술, Vol.8, No.4, pp.32-34, 1997. 4.
3 A.Sugahara, “A study of reducing strain of contact wire near a dead section”, RTRI Report, Vo. 16, No. 6, pp.15-20, 2002. 6.
4 JR 교본연구회 공저, “철도기술자를 위한 전기개론 전차선로 시리즈(3) 전차선 장치”, 일본철도전기기술협회, 1998.
5 O.Okiyama, Y.Fujii, “Current collection efficiency improved through an increased tension of the messenger wire in simple catenary equipment”, RTRI Report, Vo. 10, No. 7, pp.23-28, 1996. 7.
6 “SMSC 과천선 시운전 결과보고서”, 대우중공업, 1995. 8.
7 M.Aboshi, “Influence of wave motion of contact wire on contact force propagation”, RTRI Report, Vol.11, No.5, pp.19-24, 1997. 5.
8 “철도청 과천/분당선용 교직 전동차 시운전 보고서”, 철도청, 1993. 12.
9 “도시철도차량 표준화 국산화 연구개발보고서”, 건설교통부, 1997. 12.
10 “철도총합기술연구소편 : 전차선과 팬터그래프의 특성”, 硏友社, pp.50-51, 1993.
11 H.Nagasawa외 3인, “전차선의 고속용 데드섹션”, RRR 제10권, pp.27-32, 1992. 10.
12 최규형, 이기원, “Closed Type 절연구분장치 적용에 관한 연구” , 한국철도학회 춘계학술대회 논문집 , pp.498-502, 2002. 5.   과학기술학회마을
13 “과천선 건설 전기방식 검토 최종보고서”, 한국전기연구소, 1990. 3.
14 M.Ikeda, S.Nagasaka, “A study of diagnosis method for the overhead catenary system by contact force measurement”, RTRI Report Vol.16, No.6, pp.45-50, 2002.6.
15 J.I.Goroshkov, “Use of polymer materials inelectric railway overheads”, Rail International, pp.7-24, January 1977.