As a section insulator dividing the electric railroad catenaries with different phases, the AC/DC section insulator which divides AC and DC railroad catenary have the complex structure, and suffer irregular abrasion on the surface or insulator rods when it is installed at the underground railroad. This paper intended as an investigation of the irregular abrasion of section insulators, provides the field measurements of abrasion level along insulator length and the abrasion patterns. The height variation of insulator parts and the balding length of insulators against pantograph's contact force are analysed experimentally, and the irregular abrasion mechanism is clarified with the help of theoretical analysis on the interaction between pantographs and section insulators. On the basis of experimental and theoretical analysis, the countermeasures to reduce the irregular abrasion are provided too.
전원위상이 다른 전차선 구간을 전기적으로 구분하기 위한 절연구분장치 중에서 특히, 지하구간에 설치된 교/직 절연구분장치는 강체가선 및 조가선 가선이 혼합된 특수한 가선구조로 되어 있어, 전동차 팬터그래프와 습동하는 절연재에 불규칙한 파상마모 현상이 발생한다. 본 논문에서는, 이와 같은 절연구분장치 절연재의 마모현상에 대하여, 현장 측정을 통하여 마모정도 및 마모형태를 조사하고, 전기철도 운행 및 유지보수에 미치는 영향을 분석하였다. 그리고. 절연재 이상마모에 영향을 미칠 수 있는 요인으로서, 절연구분장치의 설치높이 편차와 팬터그래프 압상력에 대응한 절연구분장치의 변위에 대한 실험적 분석을 수행하였고, 절연구분장치와 팬터그래프간에 작용하는 접촉력에 대한 이론적 분석을 통하여 그 발생원인을 규명하였다. 이와 같은 실험적, 이론적 분석을 토대로, 효과적인 절연구분장치 개량방법을 제시하였다.