DOI QR코드

DOI QR Code

Countermeasures to Irregulor Abrasion of Section Insulators for Electric Railroad Catenary

전차선 절연구분장치 절연재의 이상마모 대책

  • Published : 2002.11.01

Abstract

As a section insulator dividing the electric railroad catenaries with different phases, the AC/DC section insulator which divides AC and DC railroad catenary have the complex structure, and suffer irregular abrasion on the surface or insulator rods when it is installed at the underground railroad. This paper intended as an investigation of the irregular abrasion of section insulators, provides the field measurements of abrasion level along insulator length and the abrasion patterns. The height variation of insulator parts and the balding length of insulators against pantograph's contact force are analysed experimentally, and the irregular abrasion mechanism is clarified with the help of theoretical analysis on the interaction between pantographs and section insulators. On the basis of experimental and theoretical analysis, the countermeasures to reduce the irregular abrasion are provided too.

전원위상이 다른 전차선 구간을 전기적으로 구분하기 위한 절연구분장치 중에서 특히, 지하구간에 설치된 교/직 절연구분장치는 강체가선 및 조가선 가선이 혼합된 특수한 가선구조로 되어 있어, 전동차 팬터그래프와 습동하는 절연재에 불규칙한 파상마모 현상이 발생한다. 본 논문에서는, 이와 같은 절연구분장치 절연재의 마모현상에 대하여, 현장 측정을 통하여 마모정도 및 마모형태를 조사하고, 전기철도 운행 및 유지보수에 미치는 영향을 분석하였다. 그리고. 절연재 이상마모에 영향을 미칠 수 있는 요인으로서, 절연구분장치의 설치높이 편차와 팬터그래프 압상력에 대응한 절연구분장치의 변위에 대한 실험적 분석을 수행하였고, 절연구분장치와 팬터그래프간에 작용하는 접촉력에 대한 이론적 분석을 통하여 그 발생원인을 규명하였다. 이와 같은 실험적, 이론적 분석을 토대로, 효과적인 절연구분장치 개량방법을 제시하였다.

Keywords

References

  1. JR 교본연구회 공저, “철도기술자를 위한 전기개론 전차선로 시리즈(3) 전차선 장치”, 일본철도전기기술협회, 1998.
  2. “과천선 건설 전기방식 검토 최종보고서”, 한국전기연구소, 1990. 3.
  3. H.Nagasawa외 3인, “전차선의 고속용 데드섹션”, RRR 제10권, pp.27-32, 1992. 10.
  4. “철도청 과천/분당선용 교직 전동차 시운전 보고서”, 철도청, 1993. 12.
  5. T.Gobida, “고속열차대응 가선재료설비의 현상”, 철도와 전기기술, Vol.8, No.4, pp.32-34, 1997. 4.
  6. 최규형, 이기원, “Closed Type 절연구분장치 적용에 관한 연구” , 한국철도학회 춘계학술대회 논문집 , pp.498-502, 2002. 5.
  7. “도시철도차량 표준화 국산화 연구개발보고서”, 건설교통부, 1997. 12.
  8. “SMSC 과천선 시운전 결과보고서”, 대우중공업, 1995. 8.
  9. J.I.Goroshkov, “Use of polymer materials inelectric railwayoverheads”, Rail International, pp.7-24, January 1977.
  10. M.Aboshi, “Influence of wave motion of contact wire oncontact force propagation”, RTRI Report, Vol.11, No.5,pp.19-24, 1997. 5.
  11. M. Shimizu 외 2인, “Development of the methods ofimproving the contact loss between overhead rigidconductor line and pantograph”, RTRI Report Vol. 16,No.6, pp. 33-38, 2002. 6,
  12. “철도총합기술연구소편 : 전차선과 팬터그래프의 특성”, 硏友社, pp.50-51, 1993.
  13. M.Ikeda, S.Nagasaka, “A study of diagnosis method forthe overhead catenary system by contact forcemeasurement”, RTRI Report Vol.16, No.6, pp.45-50,2002.6.
  14. A.Sugahara, “A study of reducing strain of contact wirenear a dead section”, RTRI Report, Vo. 16, No. 6,pp.15-20, 2002. 6.
  15. O.Okiyama, Y.Fujii, “Current collection efficiencyimproved through an increased tension of themessenger wire in simple catenary equipment”, RTRIReport, Vo. 10, No. 7, pp.23-28, 1996. 7.