• Title/Summary/Keyword: dye penetration

Search Result 181, Processing Time 0.028 seconds

MARGINAL FITNESS AND MARGINAL LEAKAGE OF FIBER-REINFORCED COMPOSITE CROWNS DEFENDING UPON LUTING CEMENTS (섬유강화형 복합레진전장관의 변연적합도 및 변연누출에 관한 연구)

  • Kim, Sun-Jong;Shin, Sang-Wan;Han, Jung-Suk;Suh, Kyu-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.618-630
    • /
    • 2000
  • As Fiber-reinforced composite restorations cannot be made without leaving a marginal gap, luting cements play a pivotal role in sealing the margins as a prevention against margnal leakage. A recently introduced adhesive resin cement system is claimed to adhere chemically, as well as mechanically, to tooth substances, dental alloys and porcelain. But when considering the clinical variation conventional cementation using Zinc Phosphate and Glass-Ionomer can be requested. A vitro study was undertaken to compare microleakage and marginal fitness of Fiber-reinforced composite crowns(Targis/Vectris) depending upon luting cements. Fifty non-carious human premolar teeth were randomly divided into five experimental groups of 10 teeth each and luted with five luting cements. ($Bistite\;II^(R),\;Super-bond^(R),\;Variolink\;II^(R)$), Zinc phosphate and Glass-Ionomer cement) After 24 hours of being luted, all specimens were thermocycled 300 times through water bath of $5^{\circ}C\;and\;55^{\circ}C$ in each bath, then the quality of the marginal fitness was measured by the Digital Microscope and marginal leakage was characterized using Dye Penetration technique and the Digital Microscope The results were as follows : 1. The mean values of marginal fit were Bistite II($46.78{\mu}m$), Variolink II($56.25{\mu}m$), Super-Bond($56.78{\mu}m$), Glass-Ionomer($99.21{\mu}m$), Zinc Phosphate($109.49{\mu}m$) indicated a statistically significant difference at p<0.001. 2. The mean microleakage values of tooth-cement interface, restoration-cement interface were increased in the order of Variolink II, Bistite II, Super-Bond, Glass-Ionomer, Zinc Phosphate 3. Crowns luted with resin cement (Bistite II, Super-Bond, Variolink II, etc) exhibited less marginal gap and marginal leakage than those luted with conventional Glass-Ionomer and Zinc Phosphate cement. 4. The results indicated that all five luting systems yielded comparable and acceptable marginal fit.

  • PDF

AN EXPERIMENTAL STUDY ON THE SEALING ABILITY OF A CALCIUM HYDROXIDE PLUG TREATED WITH DENTIN BONDING AGENT (상아질 결합제로 처리된 수산화칼슘 plug의 근단부 폐쇄능에 관한 연구)

  • Kim, Pyung-Sik;Hwang, Ho-Keel;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.187-201
    • /
    • 1996
  • The purpose of this study was to evaluate the sealing ability of a calcium hydroxide plug treated with a bonding agent. Ninety extracted human anterior teeth and premolars with single canal were used in this study. Crowns were removed. the canal's were instrumented. and the roots were randomly divided into three groups of 30 each. In control group. a single apical seat was prepared with #60 K file 1mm short of the apex and the root canal was obturated with Gutta-percha and Sealapex by the lateral condensation method. In experimental group 1 and group 2. to prepare an apical isthmus of 1mm in length. the first apical seat was prepared with a #45 K file 1mm short of the anatomical apex and with a #60 K file 2mm short for the second apical seat. Dry calcium hydroxide powders were packed in the apical isthmus with a hand plugger and #60 K file and then. the root canal was obturated with Gutta-percha and Seal apex by the lateral condensation method. In experimental group 2. following an application of the bonding agent to the plug. the root canal was obturated in the same way. The teeth of each group were immersed in a 2% methylene blue dye solution. for 1, 2, and 4 weeks. The distance from the tip of the cone to the deepest penetration was measured using the Tool maker's microscope. The results were as follows : 1. The teeth having the calcium hydroxide plug treated with the dentin bonding agent (experimental group 2) showed the lowest leakage with 1.4705mm and the control group without apical plug(no apical isthmus) showed the highest leakage with 3.1735mm. 2. The control group without apical plug showed higher leakage than experimental group 1 having the calcium hydroxide plug treated without the dentin bonding agent(p>0.05). 3. The control group without apical plug and experimental group 1, having the calcium hydroxide plug treated without the dentin bonding agent. showed higher leakage than experimental group 2. having the calcium hydroxide plug treated with the dentin bonding agent(p<0.001). 4. The immersion time had no significant effect on the degree of leakage. In conclusion, the results showed that the calcium hydroxide plug treated with the dentin bonding agent could decrease the microleakage from the root apex effectively.

  • PDF

INFLUENCE OF HEATED SPREADER ON THE SEALING ABILITY OF LATERAL CONDENSATION (측방가압충전시 Heated Spreader 사용유무가 근관밀폐에 미치는 영향)

  • Chung, Won-Gyun;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.222-232
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of heated spreader on the sealing ability of lateral condensation, compared with regular cold spreader. Forty two extracted human teeth with single canal were randomly placed into 3 experimental groups, and four additional teeth were used as positive and negative controls. Each group was prepared with Ni-Ti Profile #40 using step-down technique and obturated with standardized colored gutta-percha cone by standard(cold) lateral condensation technique, warm lateral condensation technique with Endotec and hot spreader soaked in glass bead sterilizer, each with Sealapex sealer. Control groups were not obturated, but prepared. After 2 days in 2% methylene blue, the teeth were invested and made into transparent resin blocks. And then, each block was sectioned horizontally with microtome at 1, 2, 3, 4, 5 mm levels from the apex. The linear extent of dye penetration was examined with stereomicroscope at ${\times}$20 magnification. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using an analysis of variance(ANOVA) and Scheffe test. The results were as follows ; 1. All experimental groups produced the apical microleakage. 2. The mean leakage was 1.57${\pm}$0.76mm for cold spreader group, 0.86${\pm}$0.95mm for Endotec spreader group, and 0.64${\pm}$0.93mm for hot spreader group. The difference between hot spreader group and cold spreader group was statistically significant(p<0.05). 1. At the 1 mm level, the mean ratio of area of gutta-percha was 74.58${\pm}$13.15(%) for cold spreader group, 65.42${\pm}$14.62(%) for Endotec spreader group, and 80.72${\pm}$14.63(%) for hot spreader group. There was statistically significant difference between hot spreader group and Endotec spreader group(p<0.05). 2. At the 2mm level, the mean ratio of area of gutta-percha was 87.86${\pm}$11.22(%) for cold spreader group, 66.55${\pm}$14.02(%) for Endotec spreader group, and 92.93${\pm}$7.24(%) for hot spreader group. There was statistically significant difference between Endotec spreader group and other two spreader groups(p<0.05). 3. At the level 3, 4, 5 mm, there was no statistically significant difference between each group. Within the limits of the results of this experiment, warm lateral condensation technique with hot spreader soaked in a glass bead sterilizer demonstrated favorable apical sealing effect and improved density of gutta-percha mass. Thus, it is thought that this obturation technique is effective for clinical use and beneficial to reduce condensation forces, also economical and easy. Lateral condensation, Heated spreader, canal sealing, Microleakage.

  • PDF

POLYMERIZATION SHRINKAGE, HYGROSCOPIC EXPANSION AND MICROLEAKAGE OF RESIN-BASED TEMPORARY FILLING MATERIALS (레진계 임시수복재의 중합수축, 수화팽창과 미세누출)

  • Cho, Nak-Yeon;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.115-124
    • /
    • 2008
  • The purpose of this study was to measure the polymerization shrinkage and hygroscopic expansion of resin-based temporary filling materials and to evaluate microleakage at the interface between the materials and cavity wall. Five resin-based temporary filing materials were investigated: Fermit (Vivadent), Quicks (Dentkist), Provifil (Promedica), Spacer (Vericom), Clip (Voco). Caviton (GC) was also included for comparison. Polymerization shrinkage of five resin-based temporary filling materials was measured using the bonded disc method. For the measurement of hygroscopic expansion, the discs of six cured temporary filling materials were immersed in saline and a LVDT displacement sensor was used to measure the expansion for 7 days. For estimating of microleakage, Class I cavities were prepared on 120 extracted human molars and randomly assigned to 6 groups of 20 each. The cavities in each group were filled with six temporary filling materials. All specimens were submitted to 1000 thermocycles, with temperature varying from $5^{\circ}C/55^{\circ}C$. Microleakage was determined using a dye penetration test. The results were as follows: 1. Fermit had significantly less polymerization shrinkage than the other resin-based temporary fill ing materials. Fermit (0.22%) < Spacer (0.38%) < Quicks (0.64%), Provifil (0.67%), Clip (0.67%) 2. Resin-based temporary filling materials showed 0.43-1.1% expansion in 7 days. 3. Fermit showed the greatest leakage, while Quicks exhibited the least leakage. 4. There are no correlation between polymerization shrinkage or hygroscopic expansion and microleakage of resin-based temporary filling materials.

Relationships between Airborne Droplet and Impression Diameters in Small Droplets (작은 분무입자(噴霧粒子)에 있어서 원형분무입자(原形噴霧粒子) 직경(直徑)과 살포(撒布)된 입자직경(粒子直徑)의 관계(關係))

  • Lee, Sang-Woo
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.2
    • /
    • pp.192-197
    • /
    • 1979
  • Spread factors were tried to determine the diameter of airborne droplet emitted: from the sprayer by the measurements of airborne droplet diameter emitted from the uniform size droplet producer and impression diameter on Kromekote card or Eucalypt's leaf in the different dilute concentration with Geigy Red Herbicide Dye from 0.5% to 2% by weight. The results abtained were as follows; The general form of the equation in the relationship between airborne droplet and impression diameter on Kromekote card or Eucalypt's leaf was an exponential equation as follows; $$Y=aX^b$$ which gave a linear relation on log-log graph paper. The spread factor seemed to be larger in the thin dilute concentration than in the thick dilute concentration. The spread factor was remarkably smaller on Eucalypt's leaf than on Kromekote card due to the penetration of liquid into the leaf and the stomata of the epidermis. The calculated equation of the mean depth of the droplet sprayed on Eucalypt's leaf was the same form as $Y=aX^b$, which implied that the spray liquid was distributed in surplus in accordance with the diameter of the droplet larger than the optimum size droplet to control insect and disease.

  • PDF

Evaluation of Marginal and Internal Integrity of Modified Resin-Bonded Fixed Partial Dentures: An In Vitro Study

  • Ahn, Sung-Hyeon;Choi, Jae-Won;Jeon, Yong-Chan;Jeong, Chang-Mo;Yoon, Mi-Jung;Lee, So-Hyoun;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the microleakage of various types of resin-bonded fixed partial dentures (RBFPDs) after artificial aging. Materials and Methods: Forty models with missing first molar were fabricated using artificial resin teeth and were divided into four groups: Group A, conventional RBFPDs design; Group B, modified RBFPDs design; Group C, assembled 3-piece RBFPDs design; and Group D, assembled 3-piece RBFPDs with different occlusal rest positions. Half of the specimens underwent chewing simulation process (240,000 cycles, 50 N load, 1.7 Hz) and thermocycling (temperatures $5^{\circ}C{\sim}55^{\circ}C$, dwelling time 30 seconds) and the remaining 20 specimens didn't receive any treatment. All the specimens were immersed in 2% methylene blue solution for 24 hours to evaluate microleakage, and were sectioned at the middle part of abutment teeth. To evaluate the microleaskage, a dye penetration was calculated. Result: With artificial aging, cyclic loading and thermocycling, a 3-piece RBPFD and a 2-piece RBPFD using original tooth undercuts have significantly lower microleakge (P<0.05) compared to the conventional design of RBPFD and modified RBPFD. Conclusion: Within the limit of this experiment, the assembled RBFPDs exhibited a smaller microleakage than the conventional RBFPDs, implying that the assembled RBFPDs can be more effective for reducing the dislodgement of the RBFPDs.

A STUDY ON THE MICROLEAKAGE OF COMPOMER RESTORATIONS IN CERVICAL CAVITIES OF PRIMARY MOLARS ACCORDING TO THE LENGTH OF ETCHING TIME (유치 치경부 와동 Compomer 수복에 있어서의 산부식시간에 따른 미세누출에 관한 연구)

  • Kim, Sung-Ki;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.229-236
    • /
    • 2000
  • For the purpose of evaluating the microleakage of compomer restorations in cervical cavities of primary molars according to the length of etching time, an experiment was performed through next procedures. 48 extracted human primary molars were divided into 6 groups according to applied compomers and the etching time of 0, 15, 30 seconds. All the restorations were filled under the manufacturer's direction, and the degree of dye penetration was evaluated with stereomicroscope. The microleakage of etch group was measured and statistically analyzed and obtained the results as follows: 1. Compared with groups without etching, the degree of microleakage was reduced by acid etching the cavities (p<0.05). 2. There revealed similar preventive effects of microleakage when the teeth were etched for 15 seconds and 30 seconds respectively(p>0.05). 3. No significant difference was observed between two compomers examined in this study(p>0.05). It was, therefore, thought acid etching is effective to minimize the microleakage of compomer restorations in primary teeth, and in cases of performing, 15 seconds is adequate for etching.

  • PDF

THE INFLUENCE OF IRM TEMPORARY RESTORATIONS ON MARGINAL MICROLEAKAGE OF DENTIN ADHESIVES (IRM 임시수복이 상아질 접착제의 변연 미세누출에 미치는 영향)

  • Cho, Young-Gon;Kim, Hyun-Kyung;Lee, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • This study investigated the influence of IRM on marginal microleakage of 5th generation adhesives. Class V cavities with gingival margins in dentin were prepared on both buccal and lingual surfaces of 60 extract-ed human molar teeth. Prepared teeth were randomly divided into six groups. Group 1 and 4 received no temporary restoration with IRM. Group 2 and 5 were covered with IRM mixed at P/L ratio(10g/1g). Group 3 and 6 were covered with IRM mixed at P/L ratio(10g/2g). The temporary restorations were removed mechanically with an ultrasonic scaler after one-week storage in distilled water. The cavities were restored using one of two adhesives and composites ; Single Bond/Filtek Z 250(Croup 1, 2 and 3), UniFil Bond/UniFil F(Group 4, 5 and 6). Following one day storage in distilled water, the restored teeth were thermocycled for 500 cycles(between $5^{\circ}C{\;}and{\;}55^{\circ}C$) and immersed in 2 % methylene blue for dye penetration testing. The results were analysed using Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked test at a significance level of 0.05. The results of this study were as follows 1. Ranking of mean microleakage scores at the enamel margins was Group 10.05) 4. At the dentin margins, the microleakage of the group not pretreated with IRM was lower than that of the group pretreated with IRM. And the microleakage of UniFil Bond was lower than that of Single Bond. 5. Compared with microleakages between the enamel and dentin margins of each groups, Group 1, 2, 3, 4, 5 and 6 at dentin margin were higher microleakage than those at enamel margin. There were significant difference between enamel and dentin microleakage of Group 2 and 3(p<0.05).

A STUDY ON THE CLINICAL USAGE OF THE FLOWABLE COMPOSITE RESIN (유동성 복합레진의 임상적 용도에 관한 검토 연구)

  • Park, So-Young;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.255-261
    • /
    • 2002
  • The purpose of this study was to compare the microleakage pattern of flowable composite resin to sealant, composite resin used in preventive resin restoration and glass ionomer cement used as liner. 120 extracted sound human molars were divided into 6 groups : group 1 and 2:sealant ; group 3 and 4:preventive resin restoration ; group 5 and 6:sandwich technique restoration. For the experimental groups(group 2, 4 and 6), flowable composite resin(Tetric flow) was used. For the control group, Concise was used as sealant material(group 1), Z-100 with Concise were used as preventive resin restoration(group 3), and Vitrebond was used as cavity liner(group 5). All the restorations were thermocycled and the degree of dye penetration was evaluated with stereomicroscope. The microleakage of each group was measured and statistically analyzed. The results of the present study were as follows : 1. In group 1 and 2, there was no statistically significant difference in microleakage between Concise and Tetric flow(p>0.05). 2. In groups of preventive resin restorations, there was no statistically significant difference in microleakage between Z-100 with Concise and Tetric flow(p>0.05). 3. The microleakage of Vitrebond and Tetric flow used as liner showed no statistically significant difference(p>0.05).

  • PDF

THE EFFECTS OF ND:YAG LASER AND IRRIGANTS ON CANAL SEALING ABILITY (근관치료시 Nd:YAG Laser 사용과 세척액에 따른 치근단 폐쇄효과의 비교)

  • Kim, Jin-Woon;Lee, Hee-Ju;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.307-315
    • /
    • 2001
  • The application of Nd:YAG laser and irrigants to the root surface can change its surface configurations. The purpose of this study was to investigate the effects of Nd:YAG laser and irrigants on the apical seal of obturated canals. In this study, 66 single rooted teeth were randomly assigned to 4 group of 14 teeth each. 8 teeth were served us positive and negative controls. The teeth were divided into 6 groups as follows. Group A: Nd:YAG laser, 5% NaOCl + Rc-prep Group B: Nd:YAG laser, Saline Group C: 5% NaOCl + Rc-prep Group D: Saline Group E: Positive control Group F: Negative control 66 teeth were instrumented using Maillefer ProFile$^{\circledR}$ (Orifice Shapers, .04 taper, .06 taper Dentsply, Switzerland). Two of each group were selected at random, and the canal wall surfaces were examined under a SEM. 12 teeth of each group were obturated using by lateral condensation technique. Specimens were immersed in india ink for 7days, decalcified by 10% nitric acid, dehydrated by 75. 80. 85, 90, 95 and 100% alcohol in order cleared by methyl salicylate and then measured of dye penetration with stereomicroscope($\times$15 magnification) and Image Pro plus. The data were analyzed statistically by one-way ANOVA test and Duncan's Multiple Range test. The results were as follows : 1. The mean leakage was 0.128$\pm$0.376 for group A, 0.237$\pm$0.325 for group B, 0.397$\pm$0.468 for group C, 0.586$\pm$0.402 for group D, and there were statistically significant differences between group A and group D, group B and group D. (p<0.05). 2. Group A had better sealing ability than Group C, but there was statistically no significant differences. (p>0.05). 3. Group B had better sealing ability than Group D and there was statistically significant difference. (p<0.05). 4 Group A had better sealing ability than Group B, but there was statistically no significant difference. (p>0.05). 5. Group C had better sealing ability than Group D, but there was statistically no significant difference. (p>0.05). 6. As a result of observation under SEM, Smear layers were removed in Group A, B. but Smear layers were partially removed and smear plugs were remained in Group C, Smear layers were not removed in Group D. To be specially, Melting of smear layer were showed in Group C. 7. These results suggests that the laser has a potential in reducing the apical microleakage of obturated canals.

  • PDF