Browse > Article
http://dx.doi.org/10.5856/JKDS.2017.10.1.29

Evaluation of Marginal and Internal Integrity of Modified Resin-Bonded Fixed Partial Dentures: An In Vitro Study  

Ahn, Sung-Hyeon (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Choi, Jae-Won (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Jeon, Yong-Chan (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Jeong, Chang-Mo (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Yoon, Mi-Jung (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Lee, So-Hyoun (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Huh, Jung-Bo (Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University)
Publication Information
Journal of Korean Dental Science / v.10, no.1, 2017 , pp. 29-34 More about this Journal
Abstract
Purpose: The purpose of this study was to evaluate the microleakage of various types of resin-bonded fixed partial dentures (RBFPDs) after artificial aging. Materials and Methods: Forty models with missing first molar were fabricated using artificial resin teeth and were divided into four groups: Group A, conventional RBFPDs design; Group B, modified RBFPDs design; Group C, assembled 3-piece RBFPDs design; and Group D, assembled 3-piece RBFPDs with different occlusal rest positions. Half of the specimens underwent chewing simulation process (240,000 cycles, 50 N load, 1.7 Hz) and thermocycling (temperatures $5^{\circ}C{\sim}55^{\circ}C$, dwelling time 30 seconds) and the remaining 20 specimens didn't receive any treatment. All the specimens were immersed in 2% methylene blue solution for 24 hours to evaluate microleakage, and were sectioned at the middle part of abutment teeth. To evaluate the microleaskage, a dye penetration was calculated. Result: With artificial aging, cyclic loading and thermocycling, a 3-piece RBPFD and a 2-piece RBPFD using original tooth undercuts have significantly lower microleakge (P<0.05) compared to the conventional design of RBPFD and modified RBPFD. Conclusion: Within the limit of this experiment, the assembled RBFPDs exhibited a smaller microleakage than the conventional RBFPDs, implying that the assembled RBFPDs can be more effective for reducing the dislodgement of the RBFPDs.
Keywords
Artificial aging; Denture, partial, fixed, resin-bonded; Microleakage;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Arora V, Sharma MC, Dwivedi R. Comparative evaluation of retentive properties of acid etched resin bonded fixed partial dentures. Med J Armed Forces India. 2014; 70: 53-7.   DOI
2 Wei YR, Wang XD, Zhang Q, Li XX, Blatz MB, Jian YT, Zhao K. Clinical performance of anterior resinbonded fixed dental prostheses with different framework designs: a systematic review and metaanalysis. J Dent. 2016; 47: 1-7.   DOI
3 Livaditis GJ, Thompson VP. Etched castings: an improved retentive mechanism for resin-bonded retainers. J Prosthet Dent. 1982; 47: 52-8.   DOI
4 Simon JF, Gartrell RG, Grogono A. Improved retention of acid-etched fixed partial dentures: a longitudinal study. J Prosthet Dent. 1992; 68: 611-5.   DOI
5 Schillingburg HT, Hobo S, Whitsett LD. Fundamentals of fixed prosthodontics. 2nd ed. Chicago: Quintessence; 1981.
6 Doh RM, Lee KW. Dislodgement resistance of modified resin-bonded fixed partial dentures utilizing tooth undercuts: an in vitro study. J Adv Prosthodont. 2009; 1: 85-90.   DOI
7 Boeckler AF, Morton D, Kraemer S, Geiss-Gerstdorfer J, Setz JM. Marginal accuracy of combined tooth-implant-supported fixed dental prostheses after in vitro stress simulation. Clin Oral Implants Res. 2008; 19: 1261-9.   DOI
8 Kelvin Khng KY, Ettinger RL, Armstrong SR, Lindquist T, Gratton DG, Qian F. In vitro evaluation of the marginal integrity of CAD/CAM interim crowns. J Prosthet Dent. 2016; 115: 617-23.   DOI
9 Hussey DL, Pagni C, Linden GJ. Performance of 400 adhesive bridges fitted in a restorative dentistry department. J Dent. 1991; 19: 221-5.   DOI
10 Boening KW. Clinical performance of resin-bonded fixed partial dentures. J Prosthet Dent. 1996; 76: 39-44.   DOI