• Title/Summary/Keyword: dye laser

Search Result 208, Processing Time 0.024 seconds

The Characteristics of Dye Jet and Dye Laser Output Depending on the Reynold's Number (레이놀드 수에 따른 색소 젯트의 특성 및 색소레이저의 출력변화)

  • Kim, Sung Ho;Ko, Do-Kyeong;Lee, Jong-Min;Lim, Gwon;Jo, Jae-Heung;Chang, Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.461-465
    • /
    • 1994
  • The spatial flatness of dye jet depending on the Reynold's number has analyzed by using a Michelson interferometer. When the Reynold's number of dye jet was 600, the flatness of the flow was the best. Under this condition, the dye laser with Littman-type configuration has been operated in a single longitudinal mode at the pumping energy of 0.5~1.0 mJ/pulse. The conversion efficiency and beam divergence were 4.7% and 3 mrad, respectively. ively.

  • PDF

Fabrication and lasing performance of Pyrromethene 597 dye in solid-state host media (Pyrromethene 597 고체 색소 레이저의 제작 및 출력 특성)

  • Lee, Hee-Chul;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.2
    • /
    • pp.146-151
    • /
    • 2005
  • We fabricated pyrromethene 597(PM597) solid-state dyes which were dissolved in PMMA(poly- methylmethacrylate) and characterized the lasing characteristics. The laser was end-pumped by a frequency doubled Q-switched Nd : YAG laser. We obtained the slope efficiency of $76\%$ at lasing wavelength of 585 nm. We demonstrated the laser lifetime to be more than 100,000 shots with output energy of 250 mJ and repetition rate of 4 Hz by adding singlet oxygen quencher DABCO(1,4-diazabicyclo [2,2,2]octane) to the solid-state dye.

A Numerical Analysis for Optimum Design of Multi-Stage Amplifier System of High Power Dye Laser (고출력 색소 레이저의 다단 증폭 시스템의 최적설계에 관한 수치해석)

  • 고도경
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.281-288
    • /
    • 1993
  • We have investigated the output characteristics and optimal conditions of a multi-stage amplifier system of Rhodamine 6G dye laser. The parameters in this simulation work were the beam diameter of the dye laser oscillator, the size of dye cell, the dye concentration, the number of stages in the amplifier system, and the pumping energy ratio of each amplifier at given pump energy. As a result, the output energy 10 mJ and the conversion efficiency of 40% in the two stage amplifier system were obtained with the pumping energy of 25mJ and the oscillator energy of 0.01 mJ.

  • PDF

UV ultra-short laser pulse generation and amplification (UV 극초단 레이저 펄스의 발생과 증폭)

  • 이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.324-326
    • /
    • 2004
  • We have obtained ultra-short pulses with a wavelength of 616 nm from a Distributed Feedback Dye Laser pumped by excimer laser. Using the second harmonic generation, we obtained ultra-short pulse at 308nm in ultraviolet region and also performed amplification in 3 stages of XeCl amplifiers.

  • PDF

DETECTION OF EARLY PROXIMAL CARIES WITH LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증의 진단)

  • Seol, Jae-Heon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.236-246
    • /
    • 2004
  • Artificial carious lesions in various depths were observed with visual examination using light transillumination, bite-wing radiography, laser fluorescence, and dye-enhanced laser fluorescence to determine the reproducibility, correlation of each diagnostic method, diagnostic sensitivity and diagnostic specificity. And optical densities according to demineralized times were measured whether laser fluorescence could be used as a quantitative diagnostic method. The following results were obtained whether laser fluorescence could be used for diagnosis of initial proximal caries. 1. Tau-c values of visual examination was 0.08 which showed lowest reproducibility and those of bite-wing radiography, laser fluorescence, dye-enhanced laser fluorescence were 0.60, 0.48, and 0.64, respectively which showed relatively high reproducibility. 2. The correlation between demineralization time and each examination was the highest in dye-enhanced laser fluorescence$({\gamma}=0.51)$ followed by laser fluorescence$({\gamma}=0.43)$, bite-wing radiograph$({\gamma}=0.35)$, and visual examination$({\gamma}=0.33)$. Dye-enhanced laser fluorescence and laser fluorescence showed significant correlation with demineralization time. 3. The sensitivity of laser fluorescence and dye-enhanced laser fluorescence for diagnosing approximal caries based on bite-wing radiography were 67%, 100% and those of specificity were 57%, 11% which showed diagnostic specificity was relatively lower than sensitivity. 4. The difference in optical density(DFR) between sound teeth and carious lesions according to lesion depth was high with dye-enhanced laser fluorescence compared with laser fluorescence. DFR measured with laser fluorescence according to changes in lesion depth was statistically significant but was not statistically significant with dye-enhanced laser fluorescence. Based on these results, laser fluorescence and dye-enhanced laser fluorescence have comparable diagnostic power as bite-wing radiography in early diagnosis of proximal caries.

  • PDF

Incidental Ignition of a Pulsed Dye Laser Fiber During Laryngomicrosurgery : A Case Report

  • Suh, Yun Suk;Lee, Eun Jung;Kim, Min Ki;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.1
    • /
    • pp.51-53
    • /
    • 2016
  • Surgical fires require an ignition source, oxidizer, and fuel. The pulsed dye laser (PDL) has been shown to be effective in the treatment of hypertrophic scars and keloids in dermatology. With the increasing number of applications of $CO_2$, laser as ignition source has been associated with operating room fires in the otorhinolaryngologic field. There have been many case reports on PDL-induced fires in dermatology, but until now, there were no reports in the larynx. We describe a 57-year-old patient diagnosed with laryngeal hyperkeratosis treated by PDL-assisted laryngomicrosurgery. In this case, we experienced incidental PDL tip flaring during pulsed dye laser vaporization.

  • PDF

Novel Fabrication of Platinum Counter Electrode in Dye-sensitized Solar Cells Using Nano-second Pulsed Laser Sintering

  • Lee, Jin Ah;Yoo, Kicheon;Kim, Woong;Ko, Min Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.234-234
    • /
    • 2013
  • The counter electrodes in dye-sensitized solar cells (DSSCs) play roles in not only collecting electrons from external circuit but also reducing I3- to I- in electrolytes. Generally, conventional counter electrodes for DSSCs are prepared from the high temperature treatment of the H2PtCl6 precursor solution at $400^{\circ}C$ However, the more simplified fabrication process of counter electrodes is required for the commercialization of DSSCs. In this work, we developed novel fabrication process of counter electrodes using nano-second pulsed laser. DSSCs employing counter electrodes prepared by laser process showed conversion efficiency of 6.75% with short-circuit current of 12.73 mA/cm2, open-circuit voltage of 0.74 V and fill factor of 0.72. Closer investigating of photovoltaic properties will be reported.

  • PDF

Koebner Phenomenon Delays Therapeutic Effect of Pulsed Dye Laser on Refractory Psoriasis

  • Park, Jae Wan;Shin, Sun Hye;Han, Hye Sung;Yoo, Kwang Ho
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.62-64
    • /
    • 2020
  • Psoriasis is a common chronic inflammatory skin disease that is histopathologically characterized by abnormal differentiation and hyperproliferation of keratinocytes, infiltration of T lymphocytes, and alternations of the dermal vasculature. Pulsed dye laser (PDL) is commonly used to treat cutaneous vascular lesions, and it has been studied for the treatment of localized psoriatic lesions. A 30-year-old female patient with refractory psoriasis on her forehead was treated using PDL. After two sessions, the size of the psoriatic lesion increased, which might have occurred due to koebnerization. As the patient continued to receive PDL treatment, the lesion showed significant improvement with no recurrence on the one-year follow-up. We present here a case of refractory psoriasis treated with PDL and demonstrates an association between a delayed therapeutic effect and the Koebner phenomenon.

Construction and Study of Longitudinally Pumped single Mode Pulsed Dye Laser (종펌핑 단일 종모드 섹소레이저 제작 및 특성연구)

  • 이종훈
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.43-45
    • /
    • 1989
  • Single mode pulsed incidence dye laser which has TEMoo spatial beam pattern, near gaussian temporal shape and narrow band width(less than 500MHz) has been constructed The improved performance comes as a results of cavity length(~5cm) and definition of optical path by means of longitudinal pumping. Using 1.0X10-4M RH-6G dye, conversion efficiency was approximately 2.2% and tuning range was 548-564nm.

  • PDF