• Title/Summary/Keyword: dose distribution characteristics

Search Result 122, Processing Time 0.031 seconds

Studies on Development of Breeding Technique to Increase Hanwoo(Bos taurus coreanae) I. Survey of Reproductive Status and Effect of Intraovarian $\textrm{PGF}_{2a}$ Administration on Luteolysis and Subsequent Estrus Induction (한우의 신속한 증식을 위한 번식기술 개발에 관한 연구 I. 한우 번식실태 및 $\textrm{PGF}_{2a}$의 난소실질 내 투여효과)

  • 이병천
    • Journal of Embryo Transfer
    • /
    • v.15 no.1
    • /
    • pp.77-83
    • /
    • 2000
  • The purpose of this study was to develop a breeding technique to increase Hanwoo of superior characteristics. In the present study, reproductive status of Hanwoo such as size of farm, breeding system and gestationi length was investigated. In addition, effect of low dose administration of prostaglandin F2$\alpha$(PGF2$\alpha$) on luteolysis was examined. The size of farm was classified by the total number of cows and the number of breeding stocks, respectively. The distribution of herd size of < 5, 6~10, 11~30, 31~50 and > heads was 31%, 15%, 39%, 4% and 11%, respectively. Furthermore, the distribution of breeding stock size of <5, 6~10, 11~30, 31~50 and > 50 heads was 36%, 28%, 31%, 3% and 3%, respectively. Average parity was 2.1 in breeding stock. In breeding pattern, artificial in semination(A.I), estrus synchronization-A.I and natural mating was 92.7%, 2.4% and 4.9% respectively. Gestational length of Hanwoo was ranged 253~316 days (average length : 285 days) after estrus( estrus=0). To induce luteolysis, PGF2$\alpha$ was injected into ovarian parenchyma by a modified ovarian injector. The effect of administration of 6mg PGF2$\alpha$ on luteolysis and estrus induction was betweer (P<0.01) when PGF2$\alpha$ was administered into ovarian parechyma than when administered intramuscluarly (71 vs. 91%). When PGF2$\alpha$ was injected into ovarian parenchyma, a decreased concentration to 3 mg did not significantly decreaed its luteolytic effect(92%). When AI was performed following PGF2$\alpha$ treatment, the intraovarian injection group yielded a higher pregnancy rate(69 vs. 88%) than the IM injection groups, regardless of the dosage. In conclusion these results suggest that increasing herd size and regular reproductive management are needed to improve reproductive efficiency in Hanwoo industry. Furthermore, intraovarian administration of PGF2$\alpha$ is effective way to induce luteolysis compared with intramuscular injection.

  • PDF

The Characteristics of Two-dimensional Radiation Monitoring System (2차원 방사선준위 분포측정 시스템의 제작 및 특성 조사)

  • Kim, S.H.;Han, S.H.;Kim, K.R.;Kang, H.D.;Choi, Y.S.;Lee, Y.B.;Lee, J.M.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.290-297
    • /
    • 1997
  • In this study, the radiation monitoring system using CsI(TI) scintillation counter is developed for the measurement of radiation distribution in the field of high dose level. When the inner diameter of collimator is 8 mm, we have realized the optimum detecting efficiency and spatial resolution. At that time, the position resolution was 10 cm at 1 m from the system. And experimental results indicated that the energy resolution of the system were 10 % for 662 keV of Cs-137, 7.6 % for 1.17 MeV of Co-60, and 5.8 % for 1.33 MeV of Co-60. Also, we have shown that the real radiation distribution images may be obtained by our measurement system.

  • PDF

The Radiation Dose and The Relationship between Proof Alcohol Takju Preliminary Research (방사선 조사선량과 탁주 알콜도수와의 상관관계 사전조사)

  • Kim, Seon-Chil;Cho, Young-Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.197-200
    • /
    • 2012
  • This research investigated Takju alcohol content in the case of irradiation changes in the statistical analysis was performed to visually. Lower proof alcohol fermentation Takju traditional and largely maintained 6 degrees, from the heat sterilization process is controlled through the distribution period. Most of the existing irradiation is focused on preservation of the product, but this study of the quality characteristics of the mechanical changes in alcohol was to seek value. Takju Celsius to $15^{\circ}C$, while maintaining the experiment were kept in the state. Radiation devices Varian Clinac ix, 2010 (Max. 10MV) using the field size $150mm{\times}150mm$, SSD 100 cm at 40kVp 1, 4, 7, 10, 13, 15, 20Gy were vertical. KJELDAHL APPARATUS, C-H6 Alcohol frequency was measured using. The results according to the change of the radiation dose alcohol did not show the sudden change of frequency, were observed at similar levels decreased. This study simply due to the radiation dose to be served, but to find the change in the future with a greater sense of quality changes should be considered.

Pharmacokinetics of Arsenic Hexaoxide, a Anticancer Compound, in Rats (흰쥐에서 항암성화합물인 육산화비소의 체내동태)

  • Lee, Pung-Sok;Shin, Dae-Hwan;Lee, So-Young;Lee, Jung-Yeol;Lee, Kyoung-Mi;Kwon, Koo-Hyun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.6
    • /
    • pp.377-383
    • /
    • 2006
  • The purpose of the present study was to examine the pharmacokinetic characteristics of arsenic hexaoxide($As_4O_6$), a novel anticancer compound, after i.v. bolus and oral administration in rats. We developed an ICP-Mass based method to analyze arsenic hexaoxide levels in plasma, bile, urine, feces, and tissue and validated the method. Arsenic hexaoxide rapidly disappeared from the plasma by 10 min($\alpha$ phase) after i.v. administration, which was followed by the late disappearance in the $\beta$ phase. The mean plasma half-lives($t_{1/2}$) of arsenic hexaoxide at the a and $\beta$ phase when administered at a dose of 5 mg/kg were 1.57 and 29.8 min, respectively. The maximum plasma concentration($C_{max}$) was 230 ng/mL, after oral administration of arsenic hexaoxide at a dose of 50 mg/kg. The bioavailability, which was calculated from the dose-adjusted ratio, of the oral administered arsenic hexaoxide was 1.61%. Of the various tissues tested, arsenic hexaoxide was mainly distributed in the spleen, lung, liver and kidney after oral administration. Arsenic hexaoxide levels in the spleen or lung at 24 hr after oral administration were higher than those of maximum plasma concentration($C_{max}$). The cumulative amounts of arsenic hexaoxide found in the urine by 48 hr after the administration of 50 mg/kg were 5-fold higher than those in the bile. However, the cumulative amounts in the feces were 10-fold higher compared with those of urine, suggesting that arsenic hexaoxide is mostly excreted in the feces. In conclusion, our observations indicated that arsenic hexaoxide was poorly absorbed from the gastro-intestinal tract to the blood circulation and transferred to tissues such as the spleen and lung at 24 hr after oral administration. Moreover, the majority of arsenic hexaoxide appears to be excreted in the feces by 48 hr after oral administration.

A Comparative Study on the Head and Neck Radiation Therapy for Dynamic Conformal Arc Therapy and Volumetric Modulated Arc Therapy (두경부 방사선 치료 시 입체조형동적회전조사치료와 용적변조회전조사치료에 관한 연구)

  • Kim, Deok-Ki;Choi, CheonWoong;Choi, Jae-hyock;Won, Hui-su;Park, Cheol-soo
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.208-218
    • /
    • 2015
  • Recently, radiation therapy is used in the CT existing conventional two-dimensional radiation image, and set the size and location of the tumor in a manner that the image is going to change the treatment plan. After using the simulation using CT, radiation therapy it is four-dimensional or three-dimensional treatment made possible. and radiation therapy became the more effective ever before. High technology radiation therapy such as the treatment of SRS,IMRT, IGRT, SBRT, is a need to try contemplating the possibility to apply appropriate analysis and situation, so it has its own characteristics. and then it is believed that it is necessary to analyze and try it worries the proper applicability of the situation. The configuration of the various treatment that is applicable in many hospitals is necessary to try to determine how to practically apply the patients. Critical organs surrounding tumor give a small dose to avoid side effects and then the tumor has the therapeutic effect by providing a larger dose than before the radiation treatment.

Effect of Fouling Reducing Additives on Membrane Filtration Resistance of Activated Sludge (막오염 감소제가 활성슬러지의 여과저항에 미치는 영향)

  • Chung, Tai Hak;Lee, Jong Hoon;Kim, Hyoung Gun;Bae, Young Kyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.406-413
    • /
    • 2012
  • Effect of three additives, chitosan, ferric chloride, and MPE50 on membrane fouling reduction was studied. They were introduced with various dosing rate into activated sludge, and changes in filtration resistance measured by the batch cell filtration test were evaluated. Both the filtration resistance and the specific cake resistance were minimized at 20 mg/g-MLSS with chitosan, 70 mg/g-MLSS with ferric chloride, and 20 mg/g-MLSS with MPE50 addition, respectively. Introduction of the additives into the activated sludge resulted in reduction of not only cake resistance, but also fouling resistance. However, the chitosan addition to three different activated sludge resulted in three different optimal dose of 10, 20, 30 mg/g-MLSS, respectively. This implies that the optimal dose is dependent on sludge characteristics rather than a constant value. Overdose above the optimal dosage always aggravated filterability in all cases. Zeta potential of sludge flocs, relative hydrophobicity, floc size distribution, soluble EPS concentration and supernatant turbidity were measured in order to analyze fouling reduction mechanism. Nearly neutral surface charge along with the largest particle size was observed at the optimal dose. This could be explained by particle destabilization and restabilization mechanism as positively charged additives were injected into sludge flocs of negative surface charge. Both soluble EPS concentration and supernatant turbidity also showed the lowest value at the optimal dose. These foulants are believed to be coagulated and entrapped in sludge flocs during flocculation. Chitosan and MPE50 which are cationic polymeric substances showed higher reduction in both soluble EPS and fine particles comparing with ferric chloride.

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF

A Study of Epidemiological Characteristics and Related factors in School Personnel with Hypertension (서울시 교직원의 고혈압 실태파악과 그 요인에 관한 연구)

  • Shin, Sun-Mi;Kim, Jong-Hee;Han, Kyu-Jong;Lee, Hee-Woo
    • Journal of the Korean Society of School Health
    • /
    • v.17 no.1
    • /
    • pp.55-69
    • /
    • 2004
  • Purpose : To describe epidemiological characteristics and related factors in school personnel with hypertension. Method : 5,384 school personnel (2,638 males and 2,746 females) received physical examination at the Seoul School Health Center in 2002. blood pressure(BP) was classified by JNC 7th report. Normal BP is systolic BP <120 and diastolic BP<80, prehypertension BP is 120-139 or 80-89mmHg, stage 1 hypertension BP is 140-159 or 90-99, and stage 2 hypertension >=160 or >=100 mmHg. each group was evaluated by gender. We used multiple regression and logistic regression. Results : Normotension was 20.13% in males and 48.65% in female, prehypertension 43.4% in males and 38.06% in females, stage 1 hypertension 26.38% in males and 10.99% in females, stage2 hypertension 9.59% in males and 3.2% in females. the older age group had higher distribution of stage 1 hypertension and stage 2 hypertension. The means and abnormal rates of BMI, blood sugar, total cholesterol, GOT, GPT, and GTP was higher when their blood pressure was higher. However, an alcohol habit among lifestyle factors had an inverse effect. Higher Bp was correlated to a higher BMI, FBS, and cholesterol-like dose response. In stage 1 hypertension, the related factors of hypertension for males were BMI, amount of cigarettes smoked, exercise, blood sugar, total cholesterol, and GTP. In stage 1 hypertension, age, BMI, exercise, blood sugar, total cholesterol were related factors in female. In stage 2 hypertension, age and smoking were related factors in male, and age, BMI, and cholesterol in female. Conclusions : It is possible to intervene in all related factors of hypertension except age through life-style modification and appropriate medical management. Active health promotion is needed in School personnel.

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF