• Title/Summary/Keyword: dissolved oxygen

Search Result 1,366, Processing Time 0.03 seconds

Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions (세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석)

  • Jang, Jiwoon;Hwang, Insook;Lee, Jongmok;Lee, Sunmin;Kang, Sora;Kim Pak, Youngmi;Kim, Nayoung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

Extent and persistence of dissolved oxygen enhancement using nanobubbles

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Environmental Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.427-435
    • /
    • 2016
  • In this study, change in water-dissolved oxygen (DO) was analyzed under various synthetic water qualities and nanobubbles (NBs) application conditions, such as gas type, initial DO as well as water dissolved, suspended and organic matters contents. When oxygen, rather than air, was introduced into nitrogen-desorbed ultra-pure water, the stagnation time was significantly increased. It took ten days for DO concentration to drop back to saturation. The higher the initial DO concentration, the longer particles were observed above saturation due to particle stability improvement. The oxygen mass transfer rate of 0.0482 mg/L/min was found to reach a maximum at an electrolytic concentration of 0.75 g/L, beyond which the transfer rate decreased due to adsorption of negative ions of the electrolyte at the interface. High levels of turbidity caused by suspended solids have become a barrier to dissolution of NBs oxygen into the water solution, and thus affected the transfer performance. On the other hand, by applying NBs for just an hour, up to 7.2% degradation of glucose as representative organic matter was achieved. Thus, NBs technology would maintain a high DO extent for an extended duration, and thus can improve water quality provided that water chemistry is closely monitored during its application.

On The Distribution Of Dissolved Oxygen Off The East Coast Of Korea (한국동해의 용존산소 분포의 특성에 관한 연구)

  • Park, Chung Kil
    • 한국해양학회지
    • /
    • v.14 no.2
    • /
    • pp.67-70
    • /
    • 1979
  • The characteristics of distribution of dissolved oxygen off the east coast of Korea were studied. The oxygen minimum layer was not clearly appeared on the vertical distribution of dissolved oxygen through the year. The dissolved oxygen content of the proper cold water of Japan Sea was 5.1-6.0ml/l which is very higher than those of the North Pacific region, and it means that the speed of transportation of a new and oxygen rich water from surface to deeper layer is relatively fast. Water masses in east coast of Korea can be classified by using of O$\_$2/-Salinity relations.

  • PDF

Separation of dissolved gases from water using synthesized gases based on exhalation characteristics

  • Heo, Pil Woo;Park, In Sub
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1347-1353
    • /
    • 2014
  • It's possible for a human to breathe under water, if dissolved oxygen is effectively used. Fish can stay under water using the gill which extracts dissolved oxygen from water. Water includes small amounts of oxygen, so a human needs larger amounts of water to acquire oxygen enough for underwater breathing. The exhalation gas from a human is another method to get higher amounts of oxygen under water. It mainly composes of oxygen, nitrogen and carbon dioxide. So, if only carbon dioxide is decreased, the exhalation gas has good characteristics for breathing of a human under water. In this paper, composition of the exhalation gas from a human was analyzed using GC. Based on these results, the synthesized gas was prepared and mixed into water which was used for experimental devices to analyze separation characteristics of dissolved gases from water. Experimental devices included a water pump, a hollow fiber membrane module and a vacuum pump. The effects of pressure and water flow on separation characteristics of synthesized gas were investigated. The compositions of gases separated from water using synthesized gas were investigated using GC. These results expect to be applied to the development of underwater breathing technology for a human.

Statistical Analysis of Water Quality in a Land-based Fish Farm (육상 수조식 양식장 수질 환경의 통계적 분석)

  • Kim, Hae-Ran;Ceong, Hee-Taek
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.6
    • /
    • pp.637-644
    • /
    • 2010
  • The purpose of this study is to analyze characteristics of water quality factor scientifically and develop the multiple regression model predicting dissolved oxygen to save periodic replacement costs for dissolved oxygen sensor. Correlation analysis using the environmental data obtained from 2 different land-based fish farms of the Geogeum-do, Geheung-gun coastal area during the periods from November 2008 to January 2009 shows that water temperature was negatively correlated with dissolved oxygen and pH butpH was positively correlated with salinity and dissolved oxygen. The information of Keumho fish farm in 2009 is presented by the tables which are monthly statistics of water quality factors and seasonable difference by the Duncan's post-test. Also we developed multiple regression model predicting dissolved oxygen, the usefulness of which was verified by the comparison graph between estimates and actual observations. The developed regression model shows that seawater temperature and salinity give negative affect to dissolved oxygen while pH gives positive affect to it. Lastly the seawater temperature has much higher explanatory power than pH factor.

Dissolved Oxygen Trend in Sapgyo Stream Watershed (삽교천유역의 용존산소 추세)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.6
    • /
    • pp.667-681
    • /
    • 2013
  • In this study, monthly and seasonal dissolved oxygen trends of 19 water quality measurement stations in Sapgyo stream watershed were analyzed using monthly dissolved oxygen (DO) data measured for 16 years (1995~2010). Mann-Kendall trend test and Sen's slope estimator were carried out for trend analysis. Furthermore, Sapgyo stream watershed was divided into four different sections (Sapgyo stream, Muhan stream, Gykgyo stream, and Sapgyo lake) and chi-square test of homogeneity for DO trend was carried out for four different sections. The study results indicated that most of water quality measurement stations showed increasing or non-significant trend of DO on a monthly and seasonal basis. The chi-square test of homogeneity for each water quality measurement station showed the statistical homogeneity in seasonal DO trend; however, the test results showed the statistical non-homogeneity in monthly DO trend for the stations located in the reservoir. Overall, the dissolved oxygen trend in each water quality measurement station showed different patterns depending on the location of each station and season.

The Relationship between the Characteristics of Dissolved Oxygen and the Tsushima Current in the Japan Sea in Summer (하계 동해의 용존산소 분포특성과 대마난류)

  • HONG Chol Hoon;CHO Kyu Dae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.3
    • /
    • pp.291-297
    • /
    • 1983
  • This paper describes the variations of the distribution of dissolved oxygen in the Japan Sea in summer during 1974-1977. In the Tsushima Current region of the Japan Sea the salinity maxima appears frequently in summer and the dissolved oxygen at the salinity maximum is less than that in the Japan Sea Proper Water. The Japan Sea is divided into three parts with respect to the type of vertical profiles of dissolved oxygen: The southern region of about $35^{\circ}N$ which has low dissolved oxygen similar to those in the Kuroshio region, the Japan Sea Proper Water region, and the area between about $36^{\circ}N$ and $40^{\circ}N$ which has high dissolved oxygen. The ranges of the dissolved oxygen and thermosteric anomaly(${\delta}_T$) at the salinity maximum are roughly between 4.9 and 6.5 m/l and between 210 and 240 cl/t respectively. The most frequent ranges of those values are between 5.5 and 5.7 ml/l and between 230 and 240 cl/t. The northern boundary of the Tsushima Current can be known by the characteristics of the distribuion of dissolved oxygen.

  • PDF

In-situ Calibration of Membrane Type Dissolved Oxygen Sensor for CTD (CTD용 박막형 용존산소 센서의 현장 교정)

  • DONG-JIN KANG;YESEUL KIM
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.41-50
    • /
    • 2023
  • Dissolved oxygen sensors have characteristics in which data drift occurs over time. Therefore, in-situ calibration of the dissolved oxygen sensor is essential to accurately measure the concentration of dissolved oxygen in seawater. In order to provide a method for in-situ calibration, appropriate number of samples for calibration, and laboratory calibration interval of the dissolved oxygen sensor, the dissolved oxygen sensor values were compared with the measured values by titration on a total of 133 samples from three different cruises in the Indian Ocean, Pacific Ocean, and East Sea over a period of about one year. As a result, it is preferable to calibrate the sensor value using the correlation of a straight line obtained by directly comparing the final concentration value given by the sensor and the measured value. For the accurate calibration, at least 30 samples must be used to enable in-situ calibration within an accuracy range of about 1%. In addition, it is recommended that a laboratory calibration should perform within 1 year for the membrane type dissolved oxygen sensor for CTD to achieve a performance of 70% or more.

Development of a pH/dissolved- oxygen Monitoring System Using HPTS and Rudpp (HPTS, Rudpp를 활용한 pH 및 용존산소 모니터링 시스템 연구)

  • Dong Hyuk Jeong;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.82-87
    • /
    • 2023
  • This study proposes a pH-dissolved-oxygen monitoring system using 8-HydroxyPyrene-1,3,6-trisulfonic acid Trisodium Salt (HPTS) and tris(4,7-diphenyl-1,10-phenanthroline)Ruthenium(II) chloride (Rudpp). Commercial water-quality sensors are electrochemical devices that require frequent calibration and cleaning, are subject to high maintenance costs, and have difficulties conducting measurements in real-time. The proposed pH-dissolved-oxygen monitoring system selects a thin-film sensing layer to measure the change in fluorescence intensity. This change in fluorescence intensity is based on reactions with hydrogen ions in an aqueous solution at a given pH and specific amount of dissolved oxygen. The change in fluorescence intensity is then measured using light-emitting diodes and photodiodes in response to HPTS and Rudpp. This method enables the development of a relatively small, inexpensive, and real-time measureable water-quality measurement system.

Characteristics of dissolved gases separated from water mixed with exhalation gases without using a compressor

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.10
    • /
    • pp.916-921
    • /
    • 2016
  • It is possible for humans to breathe underwater using dissolved oxygen. However, unlike fish, humans need large amounts of oxygen to breathe underwater. Water generally contains small amounts of dissolved oxygen. To get enough dissolved oxygen from water, great volumes of it should be supplied into a separation device. If exhalation gases are used, the amounts of water supplied into the membrane can be decreased. However, the characteristics of exhalation gases after passage through the separation device need to be investigated. To reuse the exhalation gases, the concentration of carbon dioxide should be decreased. A compressor is needed to supply the exhalation gases because of the high pressure generated in the membrane inlet. However, compressors require a lot of power and are heavy, so it is not proper to get the portable separation device. A system without the compressor is needed. If the pressure of the position mixed from the exhalation is less than atmosphere, the compressor is not needed. In this thesis, characteristics of the gases which are mixed with exhalation gases and separated from water after passing the membrane are investigated. The compositions of carbon dioxide, oxygen, and nitrogen are measured with the gas chromatography. The effects of water and exhalation gas flow rates on characteristics of gases separated from water after the membrane are showed.