• 제목/요약/키워드: dissipation factor standard

검색결과 13건 처리시간 0.026초

손실계수 표준기 제작 및 그 특성 (Development and Its Characteristics of a Dissipation Factor Standard)

  • 김한준;강전홍;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.527-528
    • /
    • 2006
  • A dissipation factor standard of decade type having the range of 1 to 0.0001 at the frequency of 1 kHz and 10 kHz was fabricated using "T" networks combined R and C components. The values of the fabricated dissipation factor standard were adjusted within 1% of the nominal values at 0.0001 dial range and 0.05% at the others. This dissipation factor standard is used as a working standard for calibration of a impedance measurement meter at KRISS and as a primary standard of dissipation factor field at NML-SIRIM in Malaysia.

  • PDF

항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계 (Heat Dissipation Design for KW Class Power Control Unit Mounted on Aircraft Store)

  • 최석민;김형재;정재원;이철
    • 한국항행학회논문지
    • /
    • 제24권4호
    • /
    • pp.261-266
    • /
    • 2020
  • 항공기 장착물에 KW급 전력변환장치가 탑재되는 경우, 전력 변환 시 발생하는 대량의 발열에 대한 방열설계가 고려되어야 한다. 적절한 방열을 하지 못하는 경우, 장비 오작동 및 화재의 우려가 발생하며 이는 항공기 운항에 있어 치명적인 요인이 될 수 있다. 본 논문은 항공기 장착물에 탑재되는 KW급 전력변환장치의 방열설계에 관하여 기술하였다. 전산해석을 통한 설계 및 제작 후 시험을 수행하였으며, 고전력 변환에 따른 발열부품의 급격한 발열 현상을 확인하여 해석 모델을 보정하였다. 모델 보정 후 방열구조가 개선된 형상으로 설계를 개선하였으며, 미 군사규격인 MIL-STD-810G 의 고온동작 시험을 수행하여 개선된 형상의 타당성을 검증하였다.

전기용량 부담을 이용한 전압변성기 비교 측정 시스템의 비오차 및 위상각 오차의 직선성 평가기술 (Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement System Using Capacitor Burden)

  • 정재갑;김한준;권성원;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.274-278
    • /
    • 2005
  • Voltage transformer(VT) comparison measurement system is usually used for measurements of ratio error and phase angle error of VT made in industry. Both ratio error and phase angle error in VT are critically influenced by values of burden of VT used. External burden effects on both ratio error and phase angle error in VT are theoretically calculated. From the theoretical calculation, a method of evaluation for linearity of ratio error and phase angle error in VT measurement system have been developed using the standard capacitive burdens, with negligible dissipation factor less than 10$^{-4}$. These burden consists of five standard capacitors, with nominal capacitance of 1.1 $\mu$F, 1 $\mu$F, 0.1 $\mu$F, 0.01 $\mu$F, 0.001 $\mu$F. The developed method has been applied in VT measurement system of industry, showing in good consistency and linearity within 0.001 $\%$ between theoretical and measured values.

Piezocone 시험을 이용한 해성점토의 수평압밀 특성 연구 (Horizontal Consolidation Characteristics of Marine Clay Using Piezocone Test)

  • 이강운;윤길림;채영수
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.133-144
    • /
    • 2003
  • 국내 남해안 해성점토 지반의 압밀특성을 파악하고자 Piezocone 시험으로 평가한 수평방향 압밀계수와 표준압밀 시험결과를 비교하였다. 기존에 제안된 수평방향 압밀계수 추정 방법들은 상호간의 편차가 클 뿐만 아니라 실내 압밀 시험값과 비교해도 그 차가 커서 사용하기에는 많은 불확실성을 갖고 있는 것으로 알려져 있다. 제안된 방법중에서 Torstensson(1977)의 구형모델과 공동확장이론, 수정 Cam-Clay모델의 한계상태이론을 적용한 Burns and Mayne의 방법(1998)은 본 연구지역과 같은 고소성 지반에서 신뢰성이 높은 것으로 나타났다. 이중 Burns and Mayne의 방법(1998)을 사용하여 소산시험결과를 정규화한 분석결과에 따르면 50% 압밀시의 시간계수($T_{50}$)는 0.015로 추정되었다. 또한 본 연구 지반조건과 유사현장의 시험성과를 활용하여 비교 분석한 결과 새롭게 제안한 Bums and Mayne의 방법(1998)은 실내 시험값에 비해 약 1.5배 작은 것으로 나타났다. 이러한 연구결과는 표준압밀시험 결과차가 상호간에 3~4배 차를 보이는 것을 감안할 때 상당히 양호한 것으로 나타났다. 이외에도 또 다른 차원에서 소산시험결과로부터 압밀계수를 직접 산정하는 방법으로서 국내에서 널리 사용중인 Robertson 등(1992)의 제안방법을 이용하여 새로운 도표를 제안하였다. 제안된 도표는 Burns and Mayne(1998)의 이론적 방법을 활용한 방법으로서 소성이 높은 지반에서 활용할 경우 신뢰성이 높은 것으로 나타났다.

기계적 정착된 전단보강근을 가진 RC 기둥의 구조적 거동 (Structural Behavior of RC Columns with Mechanically Anchored Crossties under Cyclic Loading)

  • 이성호;천성철;오보환;나환선;김상구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.59-62
    • /
    • 2005
  • Seven columns laterally reinforced with either mechanically anchored crossties or conventional crossties under cyclic loading are tested. 4 columns are specimens for flexural strength and 3 columns are for shear strength. Main variable is anchorage types of crossties. Conventional hooks, 180$^{\circ}$ standard hook-mechanical anchorage and all mechanical anchorage type are used. The specimens are tested under 10$\%$ axial load of nominal axial capacity of the columns combined with increasing lateral load. From the flexure test, it is found that columns with mechanical anchorages exhibit superior performance in terms of ductility and energy dissipation. The crossties with mechanical anchorages reduce buckling length of longitudinal rebar. From the shear test, it is found that. 3 specimens exhibit almost the same strength, displacement, and shear failure mode at ductility factor =2.

  • PDF

Q-증가형 캐스코드 입력단을 이용한 900 MHz RF CMOS 저 잡음 증폭기 (A 900 MHz RF CMOS LNA using Q-enhancement cascode input stage)

  • 박수양;전동환;송한정;손상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.183-186
    • /
    • 1999
  • A 900 71Hz RF band-pass amplifier for wireless communication systems is designed and fabricated. HSPICE simulation results show that the amplifier can achieve a tunable center frequency between 880 MHz and 920 MHz. The gain of designed amplifier is 19 dB at Q=88, and the power dissipation is about 61 mW under 3 V power supply by using the spiral inductor with negative-7m circuit and center frequency tunning circuit. The designed band-pass amplifier is implemented by using 0.6 um 2-poly-3-metal standard CMOS process.

  • PDF

Titan산 Barium Ceramic Capacitor의 시작 (Fabrication of Barium Titanate Ceramic Capacitors)

  • 정만영;이병선
    • 대한전자공학회논문지
    • /
    • 제4권1호
    • /
    • pp.27-39
    • /
    • 1967
  • 강유전재료로서 가장 대표적이며 전자부품으로서 많이 사용되는 것 중의 하나인 titan 산 barium 자기 capacitor의 제조방법과 그 특성을 기술하였다. 산화 titanium과 탄산 barium을 1:1 mole비로 하고 이에 몇가지의 광화제를 첨가해서 소성한 어떤 자기결정의 전기적특성은 표준치와 잘 일치하였으며 절록저항, 온도계수 및 흡수율은 일반적으로 볼 수 있는 치를 많이 넘었다. 이러한 특성을 낼 수 있는 적당한 제조방법을 알아낼 수 있었다.

  • PDF

Study of Dielectric Properties of a Potential RBD Palm Oil and RBD Soybean Oil Mixture as Insulating Liquid in Transformer

  • Azmi, Kiasatina;Ahmad, Azmier;Kamarol, Mohamad
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2105-2119
    • /
    • 2015
  • This paper reported the experimental result of dielectric properties of Refined, Bleached and Deodorized Palm Oil (RBDPO) combined with 0-50% of Refined, Bleached and Deodorized Soybean Oil (RBDSO). The dielectric strength and relative permittivity of RBDPO/RBDSO was higher compared to mineral oil at all ranges of ratios and temperatures which indicated a positive sign for its possible use as insulating liquid in a transformer. All ratios of the RBDPO/RBDSO mixture also demonstrated lower dissipation factor compared to mineral oil at 40℃, 70℃ and 90℃. Apart from that, the kinematic viscosity for the oil mixtures shown exceeded the IEC 60296 as well as the mineral oil results. 70%RBDPO/30%RBDSO mixture ratio was chosen as the best mixing percentage after comparison was made with the mineral oil and IEC 60296 standard where the mixture accumulated the most satisfactory of dielectric properties hence making it as the potential candidate for palm and soybean-based transformer oil.

Properties of $Sr_{0.8}Bi_{2.3}{(Ta_{1-x}Nb_{x})}_{2}O_{9+{\alpha}}$ Thin Films

  • Park, Sang-Jun;Jang, Gun-Eik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권1호
    • /
    • pp.22-25
    • /
    • 2000
  • Polycrystalline SBTN layered ferroelectric thin film with various Nb mole ratios were prepared by sol-gel method Pt/ $SiO_2$/Si (100) substrates. The films were annealed at different temperature and characterized in terms of phase and microstructure. The films were crystallized with a high (105) diffraction intensity and had rodike structure, SBTN films fired at 800$^{circ}C$ revealed standard hysteresis loops with no fatigue for up to 10$^{10}$ cycles. At an applied voltage of 5V the dielectric constant($varepsilon$) , dissipation factor (tan $delta$), remanent polarization(ZPr) and coercive field(Ec) of typical S $r_{0.8}$B $i_{2.3}$(T $a_{1-x}$ N $b_{x}$) $O_{9+}$$alpha$/ thin film(x=0.1) prepared on Pt/ $SiO_2$/Si (100) were about 277.7, 0.042, 3.74$mu$C/$textrm{cm}^2$, and 24.8kv/cm respectively.ly.y. respectively.ly.y.y..

  • PDF

상추의 생산단계별 Chlorpyrifos 및 Procymidone의 잔류허용기준 설정 (Persistence and Dislodgeable Residues of Chlorpyrifos and Procymidone in Lettuce Leaves under Greenhouse Condition)

  • 김영숙;박주황;박종우;이영득;이규승;김장억
    • 한국환경농학회지
    • /
    • 제21권2호
    • /
    • pp.149-155
    • /
    • 2002
  • 상추의 생산단계에서의 잔류허용기준 설정과 최종 소비단계에서의 안전성 평가자료로 활용하기 위하여 지금까지 상추수확물에서의 잔류수준과 검출빈도가 높은 것으로 알려진 살충제 chlorpyrifos 및 살균제 procymidone의 포장상태에서의 생물학적 반감기, 보관상태에 따른 잔류량 변화 그리고 세척형태에 따른 제거율을 조사하였다. 시설재배포장에서 상추중두 약제의 살포농도별 생물학적 반감기를 측정한 결과 기준량 살포의 경우 chlorpyrifos 1.2일 및 procymidone 1.3일 배량살포의 경우에는 chlorpyrifos 1.5일 및 procymidone 2.6일로 나타났다. 유통과정중에서 일어날 수 있는 두 가지 농약의 잔류량 변화를 알아보기 위해서 실온(20$^{\circ}C$) 및 냉장(4$^{\circ}C$) 상태로 보관하면서 두 약제의 잔류량 변화를 조사한 결과 반감기는 실온저장시 chlorpyrifos 3.8일, procymidone 20.9일이었고, 냉장저장시에는 chlorpyrifos 12.4일 procymidone 20.9일로 나타나 두 약제 모두 실온저장보다 냉장저장시 잔류량의 감소가 훨씬 느린 것으로 나타났다. 세척방법에 의한 잔류농약의 감소량을 조사한 결과 세제 사용시의 평균 제거율은 chlorpyrifos 48.3%, procymidone 52.6%로 나타났고, 물 사용 시에는 chlorpyrifos 31.3%, procymidone 38.1%로 나타났다.