• 제목/요약/키워드: digital $(k_0,\

검색결과 3,227건 처리시간 0.03초

X-band 송수신 모듈을 위한 높은 감쇠 정확도와 작은 위상 변동을 가진 6 비트 MMIC 디지털 감쇠기 (A 6-Bit MMIC Digital Attenuator with High Attenuation Accuracy and Small Phase Variation for X-band TR Module Applications)

  • 주인권;염인복;이정원;이수호;안창수;김선주;박동운;오승엽
    • 한국군사과학기술학회지
    • /
    • 제12권4호
    • /
    • pp.452-459
    • /
    • 2009
  • A 6-bit MMIC digital attenuator applicable to X-band TR module has been developed by using $0.5{\mu}m$GaAs pHEMT processes. The Switched-T attenuator scheme and the switched-path attenuator scheme were adopted to obtain low insertion loss and small phase variation, respectively. Resistors and transmission lines are optimized to achieve the digital attenuator with high attenuation accuracy and small phase variation. The digital attenuator has RMS error of 0.4dB, resolution of 0.5dB and dynamic range of 31.5dB. The measurement results show that in-out VSWRs are less than 1.5, phase variation is from -7 to +2 degrees and IIP3 is 36.5dBm.

2X Converse Oversampling 1.65Gb/s/ch CMOS 준 디지털 데이터 복원 회로 (2X Converse Oversampling 1.65Gb/s/ch CMOS Semi-digital Data Recovery)

  • 김길수;김규영;손관수;김수원
    • 대한전자공학회논문지SD
    • /
    • 제44권6호
    • /
    • pp.1-7
    • /
    • 2007
  • 본 논문에서는 고성능 멀티미디어 인터페이스 (High Definition Multimedia Interface: HDMI) 용 수신기의 전력 절감과 면적 감소를 위한 2X converse oversampling 방식의 준 디지털 데이터 복원 회로를 제안한다. 제안하는 데이터 복원 회로는 2X converse oversampling 방식의 데이터 검출 알고리즘과 준 디지털 구조를 이용해 전력과 유효 면적을 효과적으로 감소시킨다. 제안하는 회로의 성능을 검증하기 위해서 0.18um CMOS 공정을 이용하여 칩이 제작되었으며, 측정 결과 14.4mW의 전력을 소모하고, $0.152mm^2$의 유효 면적을 차지하며, 0.7UIpp의 Jitter tolerance 성능을 나타내므로 HDMI용 수신기의 전체 전력과 유효면적을 효과적으로 감소시킬 수 있다.

CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가 (Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner)

  • 김사학;김재홍;김종견
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.673-678
    • /
    • 2015
  • 본 연구는 최신 경향의 구강 내 스캐너로 채득된 3차원 디지털 인상의 정확도와 신뢰도를 평가하기 위해 4가지 계측 지점을 통하여 분석하였다. 주 모형과 비교하였을 때, 디지털 인상이 작게 계측되는 경향을 나타내었고, 각 계측지점별로 0.06~0.12 mm 범위의 차이를 보였다. 선행연구의 결과에 의해 임상적으로 오차범위를 허용할 수 있는 것으로 나타났으며, 환자의 진단이나 치아 교정치료 계획 수립 시 사용되는 모형에는 큰 영향이 없음을 확인할 수 있었다. 실험에서는 구강 내 상황이나 해부학적 구조를 무시하고 진행하였지만, 실제 임상에서 사용 시에는 구강 내 협소한 공간, 타액 등으로 인한 치아면의 난반사 증가, 혀 등의 해부학적 구조물로 인한 작업 방해 등의 여러 가지 요인이 인상과정에 영향을 줄 수 있을 것이라 판단된다. 추후 실험에서는 가능한 구강 내 상황을 재현한 상태에서 실험을 진행하면 좀 더 임상 적용에 도움이 될 것으로 생각된다.

Measurement Resolution of Edge Position in Digital Optical Imaging

  • Lee, Sang-Yoon;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권1호
    • /
    • pp.49-55
    • /
    • 2000
  • The semiconductor industry relies on digital optical imaging for the overlay metrology of integrated circuit patterns. One critical performance demand in the particular application of digital imaging is placed on the edge resolution that is defined as the smallest detectable displacement of an edge from its image acquired in digital from. As the critical feature size of integrated circuit patterns reaches below 0.35 micrometers, the edge resolution is required to be less than 0.01 micrometers. This requirement is so stringent that fundamental behaviors of digital optical imaging need to be explored especially for the precision coordinate metrology. Our investigation reveals that the edge resolution shows quasi-random characteristics, not being simply deduced from relevant opto-electronic system parameters. Hence, a stochastic upper bound analysis is made to come up with the worst edge resolution that can statistically well predict actual indeterminate edge resolutions obtained with high magnification microscope objectives.

  • PDF

디지털 방사선 투과영상의 식별도 평가 연구 (The Study on Image Sensitivity Evaluation For Digital Radiography Image)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.70-77
    • /
    • 2008
  • The purpose of this study is to compare the quality of digital radiography image with that of classical film images for welded structure in power plants. The CMOS(Complementary Metal Oxide Semiconductor) flat panel detecter and Agfa D5 film are used to image flaw specimens respectively. In the test, CMOS flat panel detector has been determined to have a better image than that of film image. In the IQI(Image Quality Indicator) transmission test, one or two more line can be seen in digital image than in film image. Digital Radiography Test enabled to successfully detect all defects on the weld specimens fabricated with real reheat stem pipe and boiler tube as well. In the specific comparison test, Digital radiography test detected micro flaws in the size of 0.5 mm in length by 0.5 mm in depth. However, film test has limited it to 1.0 mm in length by 1.0 mm in depth. As a result of this study, digital radiography technology is estimated well enough to perform the inspection in the industry with far more cost effective way, compared to the classical film test.

  • PDF

Low-Power, All Digital Phase-Locked Loop with a Wide-Range, High Resolution TDC

  • Pu, Young-Gun;Park, An-Soo;Park, Joon-Sung;Lee, Kang-Yoon
    • ETRI Journal
    • /
    • 제33권3호
    • /
    • pp.366-373
    • /
    • 2011
  • In this paper, we propose a low-power all-digital phase-locked loop (ADPLL) with a wide input range and a high resolution time-to-digital converter (TDC). The resolution of the proposed TDC is improved by using a phase-interpolator and the time amplifier. The phase noise of the proposed ADPLL is improved by using a fine resolution digitally controlled oscillator (DCO) with an active inductor. In order to control the frequency of the DCO, the transconductance of the active inductor is tuned digitally. The die area of the ADPLL is 0.8 $mm^2$ using 0.13 ${\mu}m$ CMOS technology. The frequency resolution of the TDC is 1 ps. The DCO tuning range is 58% at 2.4 GHz and the effective DCO frequency resolution is 0.14 kHz. The phase noise of the ADPLL output at 2.4 GHz is -120.5 dBc/Hz with a 1 MHz offset. The total power consumption of the ADPLL is 12 mW from a 1.2 V supply voltage.

방사선사진용 디지털 영상시스템의 정량적 평가에 관한 실험적 연구 (EXPERIMENTAL STUDY ON QUANTITATIVE EVALUATION OF FILM-BASED DIGITAL IMAGING SYSTEM)

  • 조형희;김은경
    • 치과방사선
    • /
    • 제24권1호
    • /
    • pp.137-147
    • /
    • 1994
  • A digital imaging system using Machintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quickcapture Frame Grabber Board was evaluated for quantitative analysis of standardized periapical film with aluminum step wedge. The results were as follows: 1. Correlation between Al thickness and gray level was high-positively associated(r²=0.99, p<0.001). 2. Correlation between measured weight of experimental lesion and estimated relative lesion volume by digital subtracted radiography was also high-positively associated (r²=0.98, p<0.001). 3. As exposure time was increased, mean gray level was decreased(p<0.01) and slope of regression line between Al thickness and gray level was also decreased (p<0.01). And when the exposure time was shorter than 0.2 second, the value of r² was relatively low. On the basis of the above results, it is considered that this digital imaging system using a Macintosh Ⅱ ci computer & a high resolution CCD monochrome camera will be useful in evaluating digitized image from standardized periapical film quantitatively.

  • PDF

Reference Driver를 사용한 10비트 10MS/s 축차근사형 아날로그-디지털 변환기 (A 10-bit 10-MS/s SAR ADC with a Reference Driver)

  • 손지수;이한열;김영웅;장영찬
    • 한국정보통신학회논문지
    • /
    • 제20권12호
    • /
    • pp.2317-2325
    • /
    • 2016
  • 본 논문은 reference driver를 이용한 10비트 10MS/s 축차근사형(SAR: Successive Approximation Register) 아날로그-디지털 변환기(ADC: Analog-to-Digital Converter)를 제안한다. 제안하는 SAR ADC는 커패시터형 디지털-아날로그 변환기(CDAC: Capacitive Digital-to-Analog Converter), 비교기, SAR 로직, 그리고 공급 전압 노이즈에 대한 내성을 향상시키는 reference driver로 구성된다. ${\pm}0.9V$의 아날로그 입력전압을 가지는 SAR ADC를 위해 reference driver는 0.45V, 1.35V의 기준 전압을 생성한다. 설계된 SAR ADC는 $0.18{\mu}m$ CMOS 공정을 이용하여 제작되었으며 1.8V의 공급전압을 사용하였다. 제안된 SAR ADC는 reference driver를 이용하여 +/- 200mV의 공급 전압 변화에서도 ${\pm}0.9V$의 입력 범위를 유지한다. 10MS/s의 샘플링 주파수에서 5.32mW의 전력을 소모한다. 측정된 ENOB는 9.11 비트 이며, DNL과 INL은 각각 +0.60/-0.74 LSB와 +0.69/-0.65 LSB이다.

디지털 구강스캐너 임상적용 경험에 따른 치과위생사의 인지도 및 선호도 변화에 관한 융합연구 (A Convergence Study on the Changes of Awareness and Preference according to the Clinical Application Experience of Digital Intraoral Scanners in Dental Hygienists)

  • 장경애;허성은;강현경;이숙정
    • 한국융합학회논문지
    • /
    • 제9권7호
    • /
    • pp.135-140
    • /
    • 2018
  • 본 연구는 디지털 구강스캐너 사용 경험에 따른 치과위생사의 인지도 및 선호도에 대한 변화를 융합연구를 통해 파악하고자 하였으며, 부산광역시와 경상 남 북도 지역의 치과위생사를 대상으로 온라인 설문에 의해 수집된 자료를 SPSS 24.0 프로그램을 통해 분석하였다. 디지털 구강스캐너 사용경험이 있을수록 디지털 구강스캐너의 인지도와 선호도가 유의하게 높게 나타났으며, 디지털 구강스캐너 사용경험은 디지털 구강스캐너 임상적용 경험과 디지털 구강스캐너 임상적용 경험은 디지털 구강스캐너 인지도와 디지털 구강스캐너의 인지도는 디지털 구강스캐너의 선호도와 정적 상관이 나타났다. 결국 치과위생사의 디지털 구강스캐너 임상적용 경험이 있을수록 그 인지도 및 선호도가 높아져 치과위생사의 업무 능력이 향상될 것으로 기대됨에 따라 디지털 구강스캐너 관련 지속적인 교육과 학습이 필요하다고 판단된다.

A Class-D Amplifier for a Digital Hearing Aid with 0.015% Total Harmonic Distortion Plus Noise

  • Lee, Dongjun;Noh, Jinho;Lee, Jisoo;Choi, Yongjae;Yoo, Changsik
    • ETRI Journal
    • /
    • 제35권5호
    • /
    • pp.819-826
    • /
    • 2013
  • A class-D audio amplifier for a digital hearing aid is described. The class-D amplifier operates with a pulse-code modulated (PCM) digital input and consists of an interpolation filter, a digital sigma-delta modulator (SDM), and an analog SDM, along with an H-bridge power switch. The noise of the power switch is suppressed by feeding it back to the input of the analog SDM. The interpolation filter removes the unwanted image tones of the PCM input, improving the linearity and power efficiency. The class-D amplifier is implemented in a 0.13-${\mu}m$ CMOS process. The maximum output power delivered to the receiver (speaker) is 1.19 mW. The measured total harmonic distortion plus noise is 0.015%, and the dynamic range is 86.0 dB. The class-D amplifier consumes 304 ${\mu}W$ from a 1.2-V power supply.