• Title/Summary/Keyword: dental material

Search Result 1,380, Processing Time 0.037 seconds

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

Condition Setting for Oral Mucosal Irritation Evaluation using Hamster Cheek Pouch (햄스터 볼주머니를 이용한 구강점막 자극평가 조건설정)

  • Park, Kyo-Hyun;Kim, Kwang-Mahn;Kim, Bae-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.405-411
    • /
    • 2015
  • Objectives: The purpose of this study is to evaluate the optimum conditions for oral mucosal irritation testing using the buccal pouch of hamsters. Methods: Test materials were applied to the buccal pouch of seven-week old male Syrian hamsters (SLC, Japan) four times at one-hour intervals and macroscopic changes were examined at 24 hours after final treatment. After sacrifice, the buccal pouches were removed and prepared for histopathological evaluation. In order to set the exposure time, we performed exposure tests of 5, 12, 18 and 23 minutes using sodium lauryl sulfate (SLS) 1% and set the treatment volume from the test results at 2, 3, or 4 ml treatment using SLS 1%, Triton X-100 1% and ethanol. After setting the experimental conditions, seven groups of materials [sodium lauryl sulfate (SLS) (1%), Triton X-100 (1%), hydrogen peroxide (3%), ethanol (100%), chlorhexidine (0.2%, 2%), phosphate buffer saline (PBS)] were assessed. Results: Experimental conditions of material exposure time were fixed as 18 minutes from the exposure tests of 5, 12, 18 or 23 min using sodium lauryl sulfate (SLS) 1%. Treated volume was set as 4 ml per each pouch from the test results of 2, 3, or 4 ml treatments using SLS 1%, Triton X-100 1% and ethanol. The results in terms of irritation degree were in the order of sodium lauryl sulfate (SLS) (1%) > Triton X-100 (1%) ${\fallingdotseq}$ hydrogen peroxide (3%) > ethanol (100%) ${\fallingdotseq}$ chlorhexidine (0.2%, 2%) > phosphate buffer saline (PBS). Conclusion: From this study, suitable conditions for hamster mucosal irritation testing were suggested and this method was verified through materials commonly used on oral mucosal membranes.

An Analysis on the UCC Media for STEAM Integrated Education (STEAM 융합교육을 위한 UCC 매체 활용 분석)

  • Woo, Hee-Sun;Yeom, Mi-Ryeong;Jung, Doo-Yong
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • The purpose of this study was to perform oral health education using UCC media in consideration of middle school students' characteristics, and to investigate the intelligence area related to knowledge conveyance, affective area related to attitude change, and psychomotor area related to behavioral change. As a result, it tried to develop further the strengths of UCC media based oral health education and overcome its weaknesses in order to increase learners' interest and have any behavioral changes. By letting learners have the education at YouTube at any time, rather than use one-time educational medium material it is possible to keep educating learners. In the future, by applying the education to health education programs and health education, it will be possible to convey education contents to learners accurately, give motivation to learners, and thereby increase educational results.

THE EFFECT OF INTERNAL IMPLANT-ABUTMENT CONNECTION AND DIAMETER ON SCREW LOOSENING

  • Ha, Chun-Yeo;Kim, Chang-Whe;Lim, Young-Jun;Jang, Kyung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.379-392
    • /
    • 2005
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection, and in molars. Purpose. The purposes of this study were: (1) to compare the initial abutment screw detorque values of the six different implant-abutment interface designs, (2) to compare the detorque values of the six different implant-abutment interface designs after cyclic loading, (3) to compare the detorque values of regular and wide diameter implants and (4) to compare the initial detorque values with the detorque values after cyclic loading. Material and methods. Six different implant-abutment connection systems were used. The cement retained abutment and titanium screw of each system were assembled and tightened to 32Ncm with digital torque gauge. After 10 minutes, initial detorque values were measured. The custom titanium crown were cemented temporarily and a cyclic sine curve load(20 to 320N, 14Hz) was applied. The detorque values were measured after cyclic loading of one million times by loading machine. One-way ANOVA test, scheffe’s test and Mann-Whitney U test were used. Results. The results were as follows : 1. The initial detorque values of six different implant-abutment connections were not significantly different(p>0.05). 2. The detorque values after one million dynamic cyclic loading were significantly different (p<0.05). 3. The SS-II regular and wide implant both recorded the higher detorque values than other groups after cyclic loading(p<0.05). 4. Of the wide implants, the initial detorque values of Avana Self Tapping Implant, MIS and Tapered Screw Vent, and the detorque values of MIS implant after cyclic loading were higher than their regular counterparts(p<0.05). 5. After cyclic loading, SS-II regular and wide implants showed higher detorque values than before(p<0.05).

The effects of bone regeneration in rabbit calvarial defect with particulated and block type of hydroxyapatite (토끼 두개골 결손부에서 블록형과 분말형 hydroxyapatite의 골전도 효과)

  • Gu, Sun-Ja;Sohn, Joo-Yeon;Lim, Hyun-Chang;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.321-329
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the bone regeneration of particulated hydroxyapatite(HA) and block type of hydroxyapatite graft in rabbit calvarial defects. Methods: An 8 mm calvarial circular defects were created in sixteen young adult New Zealand white male rabbits (weight $3.0{\sim}3.5kg$). Each defects were filled with Bio-Oss, particulated HA and block type HA. Sham surgery control defects were filled with blood clots. The specimens were harvested at 4 weeks and 8 weeks for histologic and histomorphometric evaluation. Results: Histomorphometric analysis demonstrated statistical differences in defect closure, new bone formation, and bone density of the four groups. Block type of HA group showed increased bone formation and bone density at 4 weeks and 8 weeks compared with Bio-Oss group or sham surgery control group(p<0.05). Conclusions: Block type of HA is an effective material for osteoconduction in rabbit calvarial defects, which may acts as a guide in use of these products in human application.

Histologic evaluation of $Regenafil^{TM}$ on defects of extraction socket (발치와의 결손부위에 $Regenafil^{TM}$의 임상적 적용에 관한 조직학적 연구)

  • Kye, Seung-Beom;Yang, Seung-Min;Seol, Yang-Jo;Lee, Young-Kyoo
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.533-542
    • /
    • 2003
  • The purpose of this study is to evaluate histologic result of bone substituting material on defects followed tooth extraction. We compare the histologic findings control, DFDBA, Bio-Oss(R), and $Regenafil^{TM}$, Briefly, mandibular premolar teeth were extracted available for bone filling. All alveolar sites were checked after extraction and thoroughly debrided with a dental curet to remove the periodontal ligament. Extraction sites were prepared dehiscence on buccal side 7mm height from alveolar crest. The graft materials were filled into the extraction socket and dehiscenc defects. The animals were sacrificed 12 weeks after implantation. Both treated and control mandibular sites were histologically evaluated with light microscopy. Histologic observation at 12 weeks revealed that control and experimental sites were healed uneventfully and directly apposed to new bone without any adverse tissue reaction. DFDBA and Bio-Ossn(R)sites maintain width of alveolar crest but were not fully resorbed. $Regenafil^{TM}$ sites also maintain width and particles were resorbed more than other graft materials. From this results, it was suggested that $Regenafil^{TM}$ is promising boen substituting materials maintaining the width of alveolar crest and height follewed tooth extraction.

The effect of maintenance period of non-resorbable membrane on bone regeneration in rabbit calvarial defects (가토 두개골 결손부에서 비흡수성 차단막의 유지 기간에 따른 골조직 형성효과)

  • Jung, Min-Gu;Jang, Hyun-Seon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.543-551
    • /
    • 2007
  • When clinicians faced with an insufficient volume of supporting bone on ideally esthetic and bio-mechanical position for dental implantation, guided bone regeneration(GBR) was indicated. Although GBR has wide application at clinic, proper time of membrane removal remains qustionable in using non-resorbable membrane, such as non-expanded polytetrafluoroethylene(PTFE), The aim of this study was to compare the effect of maintenance period of PTFE membrane on bone regeneration in rabbit calvarial defects. Eight adult New Zealand white female rabbits were used in this study. Four defects were surgically made in their calvaria. Using a trephine bur, 4 'through and through' defects were created and classified into 3 groups, which were consisted of control group(no graft), experimental group 1(autogenous bone)and experimental group 2(deproteinized bovine bone; $OCS-B^{(R)}$). The defects were covered with PTFE membrane($Cytoplast^{(R)}$). Membranes were removed after 1, 2, 4 and 8 weeks post-GBR procedure in 2 rabbits repectively, All rabbits were sacrificed after 8 week post-GBR procedure. Specimens were harvested and observed histologically. The results were as follow; 1) The use of graft material and membrane was necessary in GBR procedure. 2) When PTFE membranes were removed early, the most favorable bone regeneration was revealed in experimental group T, followed by experimental group II and control group. 3) On GBR, it is recommended that membrane should maintain for 4 weeks with autogenous graft. As well, the use of xenograft need longer maintenance period than autogenous bone. Further evaluations will be needed, such as histomorphologic research, more species and different kinds of graft materials. And on the basis of these studies, clinical researches would be required.

AN EXPERIMENTAL STUDY OF THE EFFECT ON PULP TEMPERATURE DURING ABUTMENT PREPARATION (지대치 형성이 치수온도에 미치는 영향에 관한 실험적 연구)

  • Kim, Byong-Ki
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.47-54
    • /
    • 1976
  • Pulpal temperature is changed in response for various conditions which were mechanical, thermal, chemical and biological stimuli. This study was performed to determine the pulpal temperature changes which were using air turbine with air-water coolant, water coolant, and conventional dental engine with water coolant and no coolant on 28 canine of dogs. In order to record pulpal temperature, pulp chamber was opened on the labiocervical area of canine. Thermocouple was inserted into pulp chamber and was fixed with filling material(dycal). Changes of pulpal temperature were recorded on the physiograph, which had been standardized temperature degree, through thermocouple to thermistor bridge and carrier preamplifier. The amount of experimental temperature change to that of control was interpreted in the pulpal cavity. The obtained results were as followings: 1. The mean normal temperature was 33.07 centigrade. 2. The temperature was decreased than normal pulpal temperature. It was 12.04 centigrade in reduction by air turbine with air-water coolant, 7.17 centigrade in reduction by air turbine with air coolant, 5.54 centigrade in reduction by conventional engine with water coolant, and 1.26 centigrade in reduction by conventional engine with no coolant. 3. The time for maximal temperature change was 53.3 seconds in reduction by air turbine with air-water coolant, 73.4 seconds in reduction by air turbine with air coolant, 50.9 seconds in reduction by conventional engine with water coolant, and 27.1 seconds in reduction by conventional engine with no coolant. 4.. After reduction was ceased, the recovery time to normal pulp temperature was 287.1 seconds in air turbine with air-water coolant, 189.0 seconds in air turbine with air coolant, 86.9 seconds in conventional engine with water coolant, and 52.9 seconds in conventional engine with no coolant respectively.

  • PDF

AN EXPERIMENTAL STUDY ON THE FATIGUE FRACTURE OF LAMINATE PORCELAIN (치과용 라미네이트 도재의 피로파괴에 관한 실험적 연구)

  • Park Charn-Woon;Bae Tae-Sung;Lee Sang-Don
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.482-505
    • /
    • 1993
  • The purpose of this study was to evaluate the fracture characteristics and the effect of resin bonding of laminate porcelain. In order to characterize the indentation-induced crack, Young's moduli and characteristic indentation dimensions were measured. The fatigue life under three point flexure test was measured using the electro-dynamic type fatigue machine, and the crack propagation with thermocycling was investigated on the condition of 15 second dwell time each in $5^{\circ}C\;and\;55^{\circ}C$ bath. The Vickers indentation pattern and the fracture surface were examined by an optical microscope and a scanning electron microscope (SEM). The results obtained were summarized as follows ; 1. Young's moduli(E) of the laminate porcelain and the resin cement used in this experiment were $62.56{\pm}3.79GPa$ and $15.01{\pm}0.12GPa$, respectively. 2. The initial crack size of the laminate porcelain was $69.19{\pm}5.94{\mu}m$ when an indentation load of 9.8N was applied, and the fracture toughness was $1.065{\pm}0.156MPa\;m^{1/2}$. 3. The fatigue life of laminate porcelain showed the constant fracture range at the stress level 27.46-35.30MPa. 4. When a cyclic flexure load was applied, the fatigue life of resin-bonded laminate porcelain was more decreased than that of laminate porcelain. 5. When a thermocycling was conducted, the crack growth rate of resin-bonded laminate porcelain was more increased than that of laminate porcelain. 6. Fracture surface showed the radial crack, the lateral crack, and the macroscopic crack branching region beneath the plastic deformation region when an indentation load of 9.8N was applied.

  • PDF

Factors Affecting Survival of Maxillary Sinus Augmented Implants (상악동 거상술을 동반한 임플란트의 생존율에 관한 기여인자)

  • In, Yeon-Soo;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.241-248
    • /
    • 2011
  • Purpose: The aim of this study was to present the clinical results of maxillary sinus augmentation implants and to evaluate the effects of various factors on the implant survival rate. Methods: In a total of 112 patients, 293 implants after sinus augmentation were performed. The total survival rate and the influence of the following factors on implant survival were evaluated; patient characteristics (sex, age, smoking, general disease), graft material, implant surface, implant installation stage, site of implant placement, length and width of implant, closure method for osseous window, residual alveolar bone height. Results: 1. Age ranged from 16 to 70 yr, with a mean of 45.7 yr. 2. Cumulative survival rate for the 293 implants with the maxillary sinus augmentation procedure was 94.9%. 3. Simultaneous implant installation was performed in 122 patients and delayed implant installation was performed in 117 implants. The average healing period after sinus elevation was 7.3 months for delayed implant installation and this procedure had a significantly higher survival rate. 4. There were no significant differences in sex, age, smoking, general disease, site of implant placement, length and width of implant, residual alveolar bone height and the survival rate. 5. RBM (Resorbable Blasting Media) implant surface and allograft groups had significantly lower survival rates. Conclusion: These data suggest that maxillary sinus augmentation may give more predictable results for autogenous bone grafts and delayed implant placement.