DOI QR코드

DOI QR Code

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha (Department of Endodontics, Ondokuz Mayis University Faculty of Dentistry) ;
  • Tek, Vildan (Department of Endodontics, Bulent Ecevit University Faculty of Dentistry) ;
  • Yilmaz, Koray (Corum Oral and Dental Center) ;
  • Uslu, Gulsah (Department of Endodontics, Ondokuz Mayis University Faculty of Dentistry)
  • Received : 2017.04.27
  • Accepted : 2017.10.09
  • Published : 2017.11.08

Abstract

Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

Keywords

References

  1. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559-567. https://doi.org/10.1097/01.DON.0000129039.59003.9D
  2. Wilcox LR, Roskelley C, Sutton T. The relationship of root canal enlargement to finger-spreader induced vertical root fracture. J Endod 1997;23:533-534. https://doi.org/10.1016/S0099-2399(97)80316-0
  3. Onnink PA, Davis RD, Wayman BE. An in vitro comparison of incomplete root fractures associated with three obturation techniques. J Endod 1994;20:32-37. https://doi.org/10.1016/S0099-2399(06)80024-5
  4. Shemesh H, Roeleveld AC, Wesselink PR, Wu MK. Damage to root dentin during retreatment procedures. J Endod 2011;37:63-66. https://doi.org/10.1016/j.joen.2010.10.002
  5. Wu MK, van der Sluis LW, Wesselink PR. Comparison of mandibular premolars and canines with respect to their resistance to vertical root fracture. J Dent 2004;32:265-268. https://doi.org/10.1016/j.jdent.2003.12.002
  6. Kishen A. Mechanisms and risk factors for fracture predilection in endodontically treated teeth. Endod Topics 2006;13:57-83. https://doi.org/10.1111/j.1601-1546.2006.00201.x
  7. Sim TP, Knowles JC, Ng YL, Shelton J, Gulabivala K. Effect of sodium hypochlorite on mechanical properties of dentine and tooth surface strain. Int Endod J 2001;34:120-132. https://doi.org/10.1046/j.1365-2591.2001.00357.x
  8. Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu MK. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation. J Endod 2009;35:236-238. https://doi.org/10.1016/j.joen.2008.10.021
  9. Friedman S, Moshonov J, Trope M. Efficacy of removing glass ionomer cement, zinc oxide eugenol, and epoxy resin sealers from retreated root canals. Oral Surg Oral Med Oral Pathol 1992;73:609-612. https://doi.org/10.1016/0030-4220(92)90108-3
  10. Alapati SB, Brantley WA, Iijima M, Clark WA, Kovarik L, Buie C, Liu J, Ben Johnson W. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments. J Endod 2009;35:1589-1593. https://doi.org/10.1016/j.joen.2009.08.004
  11. Ruddle CJ, Machtou P, West JD. The shaping movement: fifth-generation technology. Dent Today 2013;32:94, 96-9.
  12. Gambarini G, Gergi R, Naaman A, Osta N, Al Sudani D. Cyclic fatigue analysis of twisted file rotary NiTi instruments used in reciprocating motion. Int Endod J 2012;45:802-806. https://doi.org/10.1111/j.1365-2591.2012.02036.x
  13. Pedulla E, Lo Savio F, Boninelli S, Plotino G, Grande NM, Rapisarda E, La Rosa G. Influence of cyclic torsional preloading on cyclic fatigue resistance of nickel - titanium instruments. Int Endod J 2015;48:1043-1050. https://doi.org/10.1111/iej.12400
  14. Ustun Y, Topcuoglu HS, Duzgun S, Kesim B. The effect of reciprocation versus rotational movement on the incidence of root defects during retreatment procedures. Int Endod J 2015;48:952-958. https://doi.org/10.1111/iej.12387
  15. Capar ID, Arslan H, Akcay M, Uysal B. Effects of ProTaper Universal, ProTaper Next, and HyFlex instruments on crack formation in dentin. J Endod 2014;40:1482-1484. https://doi.org/10.1016/j.joen.2014.02.026
  16. Adorno CG, Yoshioka T, Jindan P, Kobayashi C, Suda H. The effect of endodontic procedures on apical crack initiation and propagation ex vivo. Int Endod J 2013;46:763-768. https://doi.org/10.1111/iej.12056
  17. Liu R, Kaiwar A, Shemesh H, Wesselink PR, Hou B, Wu MK. Incidence of apical root cracks and apical dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. J Endod 2013;39:129-132. https://doi.org/10.1016/j.joen.2012.09.019
  18. Zuolo AS, Mello JE Jr, Cunha RS, Zuolo ML, Bueno CE. Efficacy of reciprocating and rotary techniques for removing filling material during root canal retreatment. Int Endod J 2013;46:947-953. https://doi.org/10.1111/iej.12085
  19. Topcuoglu HS, Duzgun S, Kesim B, Tuncay O. Incidence of apical crack initiation and propagation during the removal of root canal filling material with ProTaper and Mtwo rotary nickel-titanium retreatment instruments and hand files. J Endod 2014;40:1009-1012. https://doi.org/10.1016/j.joen.2013.12.020
  20. Kesim B, Ustun Y, Aslan T, Topcuoglu HS, Sahin S, Ulusan O. Efficacy of manual and mechanical instrumentation techniques for removal of overextended root canal filling material. Niger J Clin Pract 2017;20:761-766. https://doi.org/10.4103/1119-3077.180069
  21. Gergi R, Sabbagh C. Effectiveness of two nickel-titanium rotary instruments and a hand file for removing gutta-percha in severely curved root canals during retreatment: an ex vivo study. Int Endod J 2007;40:532-537. https://doi.org/10.1111/j.1365-2591.2007.01254.x
  22. Tamse A. Vertical root fractures in endodontically treated teeth: diagnostic signs and clinical management. Endod Topics 2006;13:84-94. https://doi.org/10.1111/j.1601-1546.2006.00200.x
  23. Yoldas O, Yilmaz S, Atakan G, Kuden C, Kasan Z. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file. J Endod 2012;38:232-235. https://doi.org/10.1016/j.joen.2011.10.011
  24. Yared GM, Bou Dagher FE, Machtou P. Cyclic fatigue of ProFile rotary instruments after clinical use. Int Endod J 2000;33:204-207. https://doi.org/10.1046/j.1365-2591.1999.00296.x
  25. Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 2001;34:386-389. https://doi.org/10.1046/j.1365-2591.2001.00259.x
  26. Alapati SB, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endod 2003;29:667-669. https://doi.org/10.1097/00004770-200310000-00014
  27. Topcuoglu HS, Demirbuga S, Tuncay O, Pala K, Arslan H, Karatas E. The effects of Mtwo, R-Endo, and D-RaCe retreatment instruments on the incidence of dentinal defects during the removal of root canal filling material. J Endod 2014;40:266-270. https://doi.org/10.1016/j.joen.2013.07.024
  28. Kuttler S, McLean A, Dorn S, Fischzang A. The impact of post space preparation with Gates-Glidden drills on residual dentin thickness in distal roots of mandibular molars. J Am Dent Assoc 2004;135:903-909. https://doi.org/10.14219/jada.archive.2004.0336
  29. Topcuoglu HS, Duzgun S, Akpek F, Topcuoglu G. Effect of glide path and apical preparation size on the incidence of apical crack during the canal preparation using Reciproc, WaveOne, and ProTaper Next systems in curved root canals: a stereomicroscope study. Scanning 2016;38:585-590. https://doi.org/10.1002/sca.21304
  30. Nevares G, de Albuquerque DS, Freire LG, Romeiro K, Fogel HM, Dos Santos M, Cunha RS. Efficacy of ProTaper NEXT compared with Reciproc in removing obturation material from severely curved root canals: a micro-computed tomography study. J Endod 2016;42:803-808. https://doi.org/10.1016/j.joen.2016.02.010
  31. Ozyurek T. Cyclic fatigue resistance of reciproc, WaveOne, and WaveOne gold nickel-titanium instruments. J Endod 2016;42:1536-1539. https://doi.org/10.1016/j.joen.2016.06.019
  32. Zhou X, Jiang S, Wang X, Wang S, Zhu X, Zhang C. Comparison of dentinal and apical crack formation caused by four different nickel-titanium rotary and reciprocating systems in large and small canals. Dent Mater J 2015;34:903-909. https://doi.org/10.4012/dmj.2015-197
  33. Liu R, Hou BX, Wesselink PR, Wu MK, Shemesh H. The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system. J Endod 2013;39:1054-1056. https://doi.org/10.1016/j.joen.2013.04.013

Cited by

  1. Effect of Aging on Dentinal Crack Formation after Treatment and Retreatment Procedures: a Micro-CT Study vol.29, pp.6, 2017, https://doi.org/10.1590/0103-6440201802134
  2. Force and vibration generated in apical direction by three endodontic files of different kinematics during simulated canal preparation: An in vitro analytical study vol.233, pp.8, 2017, https://doi.org/10.1177/0954411919854574
  3. The potential effect of instrumentation with different nickel titanium rotary systems on dentinal crack formation—An in vitro study vol.15, pp.9, 2017, https://doi.org/10.1371/journal.pone.0238790
  4. The Influence of Root Canal Preparation with ProTaper Next, WaveOne Gold, and Twisted Files on Dentine Crack Formation vol.9, pp.12, 2017, https://doi.org/10.3390/machines9120332