• Title/Summary/Keyword: dctA

Search Result 846, Processing Time 0.033 seconds

Color Image Coding Based on Shape-Adaptive All Phase Biorthogonal Transform

  • Wang, Xiaoyan;Wang, Chengyou;Zhou, Xiao;Yang, Zhiqiang
    • Journal of Information Processing Systems
    • /
    • v.13 no.1
    • /
    • pp.114-127
    • /
    • 2017
  • This paper proposes a color image coding algorithm based on shape-adaptive all phase biorthogonal transform (SA-APBT). This algorithm is implemented through four procedures: color space conversion, image segmentation, shape coding, and texture coding. Region-of-interest (ROI) and background area are obtained by image segmentation. Shape coding uses chain code. The texture coding of the ROI is prior to the background area. SA-APBT and uniform quantization are adopted in texture coding. Compared with the color image coding algorithm based on shape-adaptive discrete cosine transform (SA-DCT) at the same bit rates, experimental results on test color images reveal that the objective quality and subjective effects of the reconstructed images using the proposed algorithm are better, especially at low bit rates. Moreover, the complexity of the proposed algorithm is reduced because of uniform quantization.

A Study on Preprocessing for Efficient Character Recognization of Shipping Container Image (운송 컨테이너 영상의 효율적인 문자인식을 위한 전처리에 관한 연구)

  • Choi, Jae-Young;Kim, Nak-Bin
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.1077-1083
    • /
    • 2000
  • 본 논문은 운송 컨테이너 식별자의 자동화 처리를 위한 문자 인식의 단계중 최종 문자 인식 전단계 까지의 처리 과정을 컨테이너의 특성에 맞게 제안하였으며, 이러한 전처리 과정은 문자 인식 시스템의 성능에 중요한 영향을 미친다. 제안한 방법은 먼저 입력된 컨테이너 컬러 영상을 명암 영상으로 바꾸고 전체 영상중 인식에 필요한 식별자 영역만을 경계선 검출과 형태학적 연산을 이용하여 추출한다. 이어서 다양한 배경색과 문자색을 판단하여 일반 문서와 같이 일관성있게 통일한 후, DCT를 이용한 명암도별 이진영역으로 분할한 후에 Otsu방법과 새로운 이진화방법을 자동으로 선택하여 효율적인 이진화가 이루어지도록 하였다. 이렇게 얻어진 이진 영상은 문자인식 단계로 넘어갈 수 있도록 개별 문자로 분할한다. 이 방법은 컨테이너 영상의 불균등한 배경색과 잡음으로 인하여 문자인식에 오류가 생기는 단점을 보완하였으며 컨테이너 특성을 최대한 반영함으로써 효과적인 전처리 결과를 얻을 수 있었다. 또한, 제안한 방법의 응용은 컨테이너 이외의 다른 상황에서도 매우 효과적으로 사용될 수 있으리라 본다.

  • PDF

Reversible Watermarking Algorithm using Difference of Quantized Coefficients in JPEG image (JPEG 영상의 양자화 계수 차이값을 이용한 가역 워터마킹 알고리즘)

  • Jo, Hyun-Wu;Lee, Hae-Yeoun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.04a
    • /
    • pp.665-668
    • /
    • 2012
  • 멀티미디어 콘텐츠는 디지털 데이터의 특성상 수정과 복제가 쉽고, 이에 따라 불법 유통과 위 변조 등의 문제가 발생할 수 있으므로 콘텐츠 보안의 중요성이 높아지고 있고 가역 워터마킹 방법은 하나의 솔루션이다. 본 논문에서는 JPEG 압축 표준에서 사용할 수 있는 가역 워터마킹 기법을 제안한다. JPEG 압축 과정 중 비손실 과정에서 유지되는 양자화 DCT 블록 데이터에 대하여 인접 블록의 계수간 차이값의 히스토그램을 계산하고, 히스토그램 쉬프팅을 통하여 가역 워터마크를 삽입한다. 디코딩 과정에서 영상에 삽입된 워터마크를 추출함과 동시에 원본 JPEG 표준 영상의 품질을 복원한다. 제안 알고리즘의 성능 평가를 위해 다양한 영상을 대상으로 영상 품질과 압축률을 평가하였다. 삽입된 영상의 PSNR과 압축률은 32.33dB과 89.69%로, 표준 JPEG 압축된 영상 대비 각 3.24dB의 PSNR 차이와 2.58%의 압축률 차이를 보였다.

Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Cho, Min-Seok;Noh, Yu-Yoon;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.203-212
    • /
    • 2016
  • Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The purpose of this study is to evaluate the correlation between the overlap volume histogram (OVH), which quantitatively shows the geometrical relationship between the PTV and OAR, and the dose differences. 4D computed tomography (4DCT) images were acquired for 10 liver cancer patients. Internal target volume-based treatment planning was performed. A 3D dose was calculated on a reference phase (end-exhalation). A 4D dose was accumulated using deformation vector fields between the reference and other phase images of 4DCT from deformable image registration, and dose differences between the 3D and 4D doses were calculated. An OVH between the PTV and selected OAR (duodenum) was calculated and quantified on the basis of specific overlap volumes that corresponded to 10%, 20%, 30%, 40%, and 50% of the OAR volume overlapped with the expanded PTV. Statistical analysis was performed to verify the correlation with the OVH and dose difference for the OAR. The minimum mean dose difference was 0.50 Gy from case 3, and the maximum mean dose difference was 4.96 Gy from case 2. The calculated range of the correlation coefficients between the OVH and dose difference was from -0.720 to -0.712, and the R-square range for regression analysis was from 0.506 to 0.518 (p-value <0.05). However, when the 10% overlap volume was applied in the six cases that had OVH value ${\leq}2$, the average percent mean dose differences were $34.80{\pm}12.42%$. Cases with quantified OVH values of 2 or more had mean dose differences of $29.16{\pm}11.36%$. In conclusion, no significant statistical correlation was found between the OVH and dose differences. However, it was confirmed that a higher difference between the 3D and 4D doses could occur in cases that have smaller OVH value.

Tracking and Interpretation of Moving Object in MPEG-2 Compressed Domain (MPEG-2 압축 영역에서 움직이는 객체의 추적 및 해석)

  • Mun, Su-Jeong;Ryu, Woon-Young;Kim, Joon-Cheol;Lee, Joon-Hoan
    • The KIPS Transactions:PartB
    • /
    • v.11B no.1
    • /
    • pp.27-34
    • /
    • 2004
  • This paper proposes a method to trace and interpret a moving object based on the information which can be directly obtained from MPEG-2 compressed video stream without decoding process. In the proposed method, the motion flow is constructed from the motion vectors included in compressed video. We calculate the amount of pan, tilt, and zoom associated with camera operations using generalized Hough transform. The local object motion can be extracted from the motion flow after the compensation with the parameters related to the global camera motion. Initially, a moving object to be traced is designated by user via bounding box. After then automatic tracking Is performed based on the accumulated motion flows according to the area contributions. Also, in order to reduce the cumulative tracking error, the object area is reshaped in the first I-frame of a GOP by matching the DCT coefficients. The proposed method can improve the computation speed because the information can be directly obtained from the MPEG-2 compressed video, but the object boundary is limited by macro-blocks rather than pixels. Also, the proposed method is proper for approximate object tracking rather than accurate tracing of an object because of limited information available in the compressed video data.

Understanding Problem-Solving Type Inquiry Learning and it's Effect on the Improvement of Ability to Design Experiments: A Case Study on Science-Gifted Students (문제해결형 탐구학습에 대한 인식과 학습이 실험 설계 능력에 미친 효과 : 과학 영재학생들에 대한 사례 연구)

  • Ju, Mi-Na;Kim, Hyun-Joo
    • Journal of The Korean Association For Science Education
    • /
    • v.33 no.2
    • /
    • pp.425-443
    • /
    • 2013
  • We developed problem-solving type inquiry learning programs reflecting scientists' research process and analyzed the activities of science-gifted high school students, and the understanding and the effects of the programs after implementation in class. For this study, twelve science-gifted students in the 10th grade participated in the program, which consisted of three different modules - making a cycloidal pendulum, surface growth, and synchronization using metronomes. Diet Cola Test (DCT) was used to find out the effect on the improvement of the ability to design experiments by comparing pre/post scores, with a survey and an interview being conducted after the class. Each module consisted of a series of processes such as questioning the phenomenon scientifically, designing experiments to find solutions, and doing activities to solve the problems. These enable students to experience problem-solving type research process through the program class. According to this analysis, most students were likely to understand the characteristics of problem-solving type inquiry learning programs reflecting the scientists' research process. According to the students, there are some differences between this program class and existing school class. The differences are: 'explaining phenomenon scientifically,' 'designing experiments for themselves,' and 'repeating the experiments several times.' During the class students have to think continuously, design several experiments, and carry them out to solve the problems they found at first. Then finally, they were able to solve the problems. While repeating this kind of activities they have been able to experience the scientists' research process. Also, they showed a positive attitude toward the scientists' research by understanding problem-solving type research process. These problem-solving type inquiry learning programs seem to have positive effects on students in designing experiments and offering the opportunity for critical argumentation on the causes of the phenomena. The results of comparing pre/post scores for DCT revealed that almost every student has improved his/her ability to design experiments. Students who were accustomed to following teacher's instructions have had difficulty in designing the experiments for themselves at the beginning of the class, but gradually, they become used to doing it through the class and finally were able to do it systematically.

Comparison of Feature Performance in Off-line Hanwritten Korean Alphabet Recognition (오프라인 필기체 한글 자소 인식에 있어서 특징성능의 비교)

  • Ko, Tae-Seog;Kim, Jong-Ryeol;Chung, Kyu-Sik
    • Korean Journal of Cognitive Science
    • /
    • v.7 no.1
    • /
    • pp.57-74
    • /
    • 1996
  • This paper presents a comparison of recognition performance of the features used inthe recent handwritten korean character recognition.This research aims at providing the basis for feature selecion in order to improve not only the recognition rate but also the efficiency of recognition system.For the comparison of feature performace,we analyzed the characteristics of theose features and then,classified them into three rypes:global feature(image transformation)type,statistical feature type,and local/ topological feature type.For each type,we selected four or five features which seem more suitable to represent the characteristics of korean alphabet,and performed recongition experiments for the first consonant,horizontal vowel,and vertical vowel of a korean character, respectively.The classifier used in our experiments is a multi-layered perceptron with one hidden layer which is trained with backpropagation algorithm.The training and test data in the experiment are taken from 30sets of PE92. Experimental results show that 1)local/topological features outperform the other two type features in terms of recognition rates 2)mesh and projection features in statical feature type,walsh and DCT features in global feature type,and gradient and concavity features in local/topological feature type outperform the others in each type, respectively.

  • PDF

Studies of Inhibitory Mechanism on Melanogenesis by Partially Purified Asiasari radix in α-MSH Stimulated B16F10 Melanoma Cells (세신추출물이 α-MSH 자극에 의한 B16F10 세포의 멜라닌생성에 미치는 영향)

  • Jang, Ji-Yeon;Kim, Ha-Neui;Kim, Yu-Ri;Kim, Byung-Woo;Choi, Yung-Hyun;Choi, Byung-Tae
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1617-1624
    • /
    • 2010
  • Recently, it has been found that Asiasari radix showed a hypopigmenting effect on melanogenesis through activation of mitogen-activated protein kinase (MEK)/extracellular signal-activated kinase (ERK) in B16F10 melanoma cells. However, the hypopigmenting effect of A. radix on the $\alpha$-melanocyte stimulating hormone ($\alpha$-MSH)-stimulated melanogenesis has remained unknown. The purpose of this study was to investigate the inhibitory mechanism of the partially purified A. radix (PPAR)-induced hypopigmentating effects on $\alpha$-MSH-stimulated melanogenesis in B16F10 mouse melanoma cells. PPAR strongly inhibited tyrosinase activity and leads to decreased melanin synthesis in $\alpha$-MSH-stimulated B16F10 melanoma cells. PPAR also decreased the $\alpha$-MSH-induced over-expression of the melanogenic enzymes, tyrosinase, tyrosinase-related protein (TRP)-1, dopachrome tautomerase (Dct) and microphthalmia-associated transcription factor (MITF). We further showed that PPAR inhibits $\alpha$-MSH-induced melanogenesis via phosphorylation of MEK/ERK and PI3K/Akt, and that their activation was blocked by MEK inhibitors, PD98059 and PI3K inhibitors, LY294002 in $\alpha$-MSH-stimulated B16F10 melanoma cells. These results suggest that PPAR inhibits $\alpha$-MSH-induced melanogenesis by activation of MEK/ERK and PI3K/Akt through MITF degradation, which may lead to down-regulation of tyrosinase.

Application of the ExacTrac System in Respiratory Gated Radiotherapy for Lung Cancer Patients (폐암 환자의 호흡연동방사선치료를 위한 ExacTrac 시스템 적용)

  • Ko, Seung Young;Lee, Jung Il
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.325-332
    • /
    • 2019
  • This study analyzed the movement of tumors using 4DCT. Appropriate uniform IM were identified using TC, II and CI depending on ITV margins. DVH and NTCP were also compared in each case. Dose analysis on tumors with uniform IM showed that the optimal treatment plan for satisfying all TC, CI, II was evaluated as 2 mm in phase 20 and 3 mm in 40%. That was compared to the dose from the normal tissues of $PTV_{20}$, $PTV_{40}$. In the 20% radiation field, V5, V10, and V20 for the lungs increased 1.49, 1.26, and 0.65%, while 40% increased by 1.9, 2.41 and 1.23%. NTCP had a dose increase of 0.57 to 0.029% from 20% and 40%. There was a dose increase in the spinal cord and heart at uniform IM, but there was no significant difference. These data suggest that the ITV setting of 20%, phase for Respiratory Gated Radiotherapy using Novalis ExacTrac system can be applied with a uniform IM 2 mm and 40% with 3 mm for optimal treatment plan.

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.