• 제목/요약/키워드: current-voltage

검색결과 11,641건 처리시간 0.054초

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

저압 직류 배전용 양극성 DC-DC 컨버터에 관한 연구 (A Study on Bipolar DC-DC Converter for Low Voltage Direct Current Distribution)

  • 이정용;김호성;조진태;김주용;조영훈
    • 전력전자학회논문지
    • /
    • 제24권4호
    • /
    • pp.229-236
    • /
    • 2019
  • This study proposes a DC-DC converter topology of solid-state transformer for low-voltage DC distribution. The proposed topology consists of a voltage balancer and bipolar DC-DC converter. The voltage and current equations are obtained on the basis of switching states to design the controller. The open-loop gain of the controller is achieved using the derived voltage and current equations. The controller gain is selected through the frequency analysis of the loop gain. The inductance and capacitance are calculated considering the voltage and current ripples. The prototype is fabricated in accordance with the designed system parameters. The proposed topology and designed controller are verified through simulation and experiment.

저전압 대전류용 개방형 DC-DC 컨버터 모듈에 관한 연구 (A Study on Open-frame Type DC-DC Converter Module for Low-Voltage High-Current Applications)

  • 안태영;황선민;조인호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권4호
    • /
    • pp.183-190
    • /
    • 2003
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and current doubler rectifier. The converter module is designed with the specifications of an 1.8V output voltage, 25A output current, and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction fuss at high current level and current-mode control is adapted to enhance the flexibility in the system configuration. A prototype converter module is successfully implemented within 10mm height and half brick size (58${\times}$61mm), and recorded an 84% efficiency and 4% voltage regulation for the entire input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

저전압 대전류용 개방형 DC-DC 컨버터 모듈에 관한 연구 (A Study on Open-frame Type DC-DC Converter Module for Low-Voltage High-Current Applications)

  • 안태영;황선민;조인호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.183-183
    • /
    • 2003
  • We report the performance of an open-frame type low-voltage high-current DC-DC converter module developed using an active clamp forward converter circuit and current doubler rectifier. The converter module is designed with the specifications of an 1.8V output voltage, 25A output current, and 36-75V input voltage. The synchronous rectifier is used to reduce the conduction fuss at high current level and current-mode control is adapted to enhance the flexibility in the system configuration. A prototype converter module is successfully implemented within 10mm height and half brick size (58×61mm), and recorded an 84% efficiency and 4% voltage regulation for the entire input voltage range, thereby demonstrating its application potentials to future telecommunication electronics.

평균 모델을 이용한 Z-소스 인버터의 제어 (Control of the Z-Source Inverter using Average Model)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제19권3호
    • /
    • pp.290-296
    • /
    • 2014
  • This paper presents a design strategy for the control of the Z-source inverter (ZSI). For the Z-network capacitor voltage control, the average current model is derived to describe the dynamics of the voltage control and the controller outputs the average current command for the capacitor. Z-network inductor current reference is derived from the average current model of the Z-network capacitor. The inner current control loop outputs the average voltage command for the Z-network inductor and the shoot-through duty ratio of the ZSI is calculated from the output using the average voltage model of the Z-network inductor. The gain values of the current and voltage controllers are directly obtained by the Z-network parameters and desired bandwidth of each controller without a gain tuning process.

고정도 바이폴라 트랜스레지스턴스 증폭기 (High-Accuracy Bipolar Transresistance Amplifier)

  • 김동용;김종필차형우정원섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.667-670
    • /
    • 1998
  • Novel bipolar transresistance amplifier(TRA) for high-accuracy current-mode signal processing is described. The TRA consists of two current follower for the current inputs, a current summer for curent-differential, and a voltage follower for the voltage output. The simulation results show that the impedence of the current input and the voltage output is 0.5 $\Omega$ and the 3-dB cutoff frequency when used as a current to voltage converter extends beyond 40 MHz.

  • PDF

약계자 영역에서 최대전압 설정에 관한 연구 (The Study of the method of calculating Maximum voltage in Flux-Weakening Region)

  • 김장목;임익헌;류홍우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.26-30
    • /
    • 1999
  • The constraint condition is the stator voltage and the stator current to operate the motor in the flux weakening region. The maximum current is limited by the inverter current rating and the machine thermal rating. Given DC link voltage to control the motor in the flux weakening the maximum voltage is determined by considering PWM strategy, dead time, voltage drop of the inverter switching device, and the margin of the voltage for current forcing. In this paper, the new method to determine the available maximum voltage is derived by the analythic method and by considering the factors of the voltage drop. So Determining the maximum voltage is very useful to enlarge the speed operation region in the flux weakening operation, the utility of the maximum voltage is increased.

  • PDF

A Voltage-Down Converter for Low-Voltage SoC

  • Yi Won-jae;Lee Se-chul;Kang Tae-kyoung;Lim Gyu-Ho;Huh Young;Park Mu-Hun;Kim Young-Hee
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.66-69
    • /
    • 2004
  • This work is the study of Voltage-Down Converter used as internal supply voltage having large current driving and stable voltage level at any variation of process, voltage, and temperature(P.V.T). It converts VDD(external supply voltage) into $V_{1NT}(internal\;supply\;voltage).$ From the simulation results, a new Voltage-Down Converter has large current driving and a little stand-by current under lower supply voltage than conventional circuit. And bad characteristic of VINT, peaking, was eliminated. Start-up circuit for BGR is also added to one circuit, which consumes less current dissipation than convention circuit

  • PDF

해석학적 전류-전압모델을 이용한 이중게이트 MOSFET의 전송특성분석 (Analysis of Transport Characteristics for Double Gate MOSFET using Analytical Current-Voltage Model)

  • 정학기
    • 한국정보통신학회논문지
    • /
    • 제10권9호
    • /
    • pp.1648-1653
    • /
    • 2006
  • 이 연구에서는 해석학적 전류-전압 모델을 이용하여 DGMOSFET(Double Gate MOSFET)의 전송특성을 분석하였다. MOSFET의 게이트길이가 100nm이하로 작아지면 산화막두께가 1.5m이하로 작아져야만하고 채널의 도핑이 매우 증가하기 때문에 소자의 문턱전압변화, 누설전류의 증가 등 다양한 문제가 발생하게 된다 이러한 문제를 조사하기 위하여 해석학적 전류-전압 모델을 이용하여 소자의 크기를 변화시키면서 전류-전압특성을 조사하였다 소자의 크기를 변화시키면서 해석학적 전류-전압 모델의 타당성을 조사하였으며 온도 변화에 대한 특성도 비교 분석하였다. 게이트 전압이 2V에서 77K의 전류-전압 특성이 실온에서 보다 우수하다는 것을 알 수 있었다.

교류전원 구동방식에 의한 형광 OLED의 발광 특성 (Emission Characteristics of Fluorescent OLED with Alternating Current Power Source Driving Method)

  • 서정현;김지현;주성후
    • 한국전기전자재료학회논문지
    • /
    • 제27권2호
    • /
    • pp.104-109
    • /
    • 2014
  • To operate organic light emitting device (OLED) with alternating current (AC) power source without AC/DC(direct current) converter, we fabricated the fluorescent OLED and measured the emission characteristics with AC and DC. The OLED operated by AC showed higher maximum current efficiency of 8.2 cd/A and maximum power efficiency of 8.3 lm/W. But current efficiency and power efficiency of AC driven OLED showed worse than DC driven OLED at high voltage above 10 V. This result can be explained by the peak voltage of AC was $\sqrt{2}$ times than DC, In case of low driving voltage the emission characteristics were improved by the peak voltage of AC, but in case of high driving voltage the emission efficiencies were decreased by the roll off phenomena. Finally, serial OLED arrays using twelve OLEDs driven by AC 110 V showed average voltage of 9.17 V, voltage uniformity of 99.0%, average luminance of $1,175cd/m^2$, luminance uniformity of 94.4%.