• Title/Summary/Keyword: cryo-EM

Search Result 23, Processing Time 0.023 seconds

Workflow of Cryo-Electron Microscopy and Status of Domestic Infrastructure

  • Choi, Ki Ju;Shin, Jae In;Lee, Sung Hun
    • Applied Microscopy
    • /
    • v.48 no.1
    • /
    • pp.6-10
    • /
    • 2018
  • Cryo-electron microscopy (cryo-EM) allows the analysis of the near-native structures of samples such as proteins, viruses, and sub-cellular organelles at the sub-nano scale. With the recent development of analytical methods, this technique has achieved remarkable results. The importance of cryo-EM gained wide recognition due to last year's award of the Nobel Prize in Chemistry. To help promote the knowledge of this technique, this paper introduces the basic workflows of cryo-EM and domestic cryo-EM service institutes.

Toward High-Resolution Cryo-Electron Microscopy: Technical Review on Microcrystal-Electron Diffraction

  • Lee, Sangmin;Chung, Jeong Min;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • v.47 no.4
    • /
    • pp.223-225
    • /
    • 2017
  • Cryo-electron microscopy (cryo-EM) is arguably the most powerful tool used in structural biology. It is an important analytical technique that is used for gaining insight into the functional and molecular mechanisms of biomolecules involved in several physiological processes. Cryo-EM can be separated into the following three groups according to the analytical purposes and the features of the biological samples: cryo-electron tomography (cryo-ET), cryo-single-particle reconstruction, and cryo-electron crystallography. Cryo-tomography is a unique EM technique that is used to study intact biomolecular complexes within their original environments; it can provide mechanistic insights that are challenging for other EM-methods. However, the resolution of reconstructed three-dimensional (3D) models generated by cryo-ET is relatively low, while single-particle reconstruction can reproduce biomolecular structures having near-atomic resolution without the need for crystallization unless the samples are large (>200 kDa) and highly symmetrical. Cryo-electron crystallography is subdivided into the following two categories according to the types of samples: one category that deals with two-dimensional (2D) crystalline arrays and the other category that uses 3D crystals. These two categories of electron-crystallographic techniques use different diffraction data obtained from still diffraction and continuous-rotation diffraction. In this paper, we review crystal-based cryo-EM techniques and focus on the recently developed 3D electron-crystallographic technique called microcrystal-electron diffraction.

Advanced Cryo-Electron Microscopy Technology: High Resolution Structure of Macromolecules

  • Chung, Jeong Min;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • Recent cryo-electron microscopy (EM) studies reported the structure of various types of proteins at high resolution which is sufficient to visualize the intermolecular interaction at near atomic level. There are two main factors that cause the advances in cryo-EM; the development of image processing techniques, such as single particle analysis, and the improved electron detection devices. Although the atomic structures of small and asymmetric proteins are not yet to be determined by cryo-EM, this striking improvement implies the bright prospect of the application in biomedical studies. This study reviews the recently published studies reported high resolution structures using improved imaging analysis techniques and electron detectors. Furthermore, we will discuss about the future aspects of cryo-EM application.

Real-Time Measurement of the Liquid Amount in Cryo-Electron Microscopy Grids Using Laser Diffraction of Regular 2-D Holes of the Grids

  • Ahn, Jinsook;Lee, Dukwon;Jo, Inseong;Jeong, Hyeongseop;Hyun, Jae-Kyung;Woo, Jae-Sung;Choi, Sang-Ho;Ha, Nam-Chul
    • Molecules and Cells
    • /
    • v.43 no.3
    • /
    • pp.298-303
    • /
    • 2020
  • Cryo-electron microscopy (cryo-EM) is now the first choice to determine the high-resolution structures of huge protein complexes. Grids with two-dimensional arrays of holes covered with a carbon film are typically used in cryo-EM. Although semi-automatic plungers are available, notable trial-and-error is still required to obtain a suitable grid specimen. Herein, we introduce a new method to obtain thin ice specimens using real-time measurement of the liquid amounts in cryo-EM grids. The grids for cryo-EM strongly diffracted laser light, and the diffraction intensity of each spot was measurable in real-time. The measured diffraction patterns represented the states of the liquid in the holes due to the curvature of the liquid around them. Using the diffraction patterns, the optimal time point for freezing the grids for cryo-EM was obtained in real-time. This development will help researchers rapidly determine high-resolution protein structures using the limited resource of cryo-EM instrument access.

Review on the structural understanding of the 10S myosin II in the era of Cryo-electron microscopy

  • Anahita Vispi Bharda;Hyun Suk Jung
    • Applied Microscopy
    • /
    • v.52
    • /
    • pp.9.1-9.5
    • /
    • 2022
  • The compact smooth muscle 10S myosin II is a type of a monomer with folded tail and the heads bending back to interact with each other. This inactivated form is associated with regulatory and enzymatic activities affecting myosin processivity with actin filaments as well as ATPase activity. Phosphorylation by RLC can however, shuttle myosin from the inhibited 10S state to an activated 6S state, dictating the equilibrium. Multiple studies contributed by TEM have provided insights in the structural understanding of the 10S form. However, it is only recently that the true potential of Cryo-EM in deciphering the intramolecular interactions of 10S myosin state has been realized. This has led to an influx of new revelations on the 10S inactivation, unfolding mechanism and association in various diseases. This study reviews the gradual development in the structural interpretation of 10S species from TEM to Cryo-EM era. Furthermore, we discuss the utility of Cryo-EM in future myosin 10S studies and its contribution to human health.

Cryo-EM as a powerful tool for drug discovery: recent structural based studies of SARS-CoV-2

  • Han‑ul Kim;Hyun Suk Jung
    • Applied Microscopy
    • /
    • v.51
    • /
    • pp.13.1-13.7
    • /
    • 2021
  • The novel coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has arisen as a global pandemic affecting the respiratory system showing acute respiratory distress syndrome (ARDS). However, there is no targeted therapeutic agent yet and due to the growing cases of infections and the rising death tolls, discovery of the possible drug is the need of the hour. In general, the study for discovering therapeutic agent for SARS-CoV-2 is largely focused on large-scale screening with fragment-based drug discovery (FBDD). With the recent advancement in cryo-electron microscopy (Cryo-EM), it has become one of the widely used tools in structural biology. It is effective in investigating the structure of numerous proteins in high-resolution and also had an intense influence on drug discovery, determining the binding reaction and regulation of known drugs as well as leading the design and development of new drug candidates. Here, we review the application of cryo-EM in a structure-based drug design (SBDD) and in silico screening of the recently acquired FBDD in SARS-CoV-2. Such insights will help deliver better understanding in the procurement of the effective remedial solution for this pandemic.

Effects of various freezing containers for vitrification freezing on mouse oogenesis

  • Kim, Ji Chul;Kim, Jae Myeoung;Seo, Byoung Boo
    • Journal of Animal Science and Technology
    • /
    • v.58 no.3
    • /
    • pp.13.1-13.7
    • /
    • 2016
  • Background: In the present study, various freezing containers were tested for mouse embryos of respective developmental stages; embryos were vitrified and then their survival rate and developmental rate were monitored. Mouse two cell, 8 cell, and blastula stage embryos underwent vitrification freezing-thawing and then their recovery rate, survival rate, development rate, and hatching rate were investigated. Methods: EM-grid, OPS, and cryo-loop were utilized for vitrification freezing-thawing of mouse embryos. Results: It was found that recovery rate and survival rate were higher in the group of cryo-loop compared to those of EM-grid (p < 0.05). Embryonic development rate, two cell embryos to blastocyst, as well as hatching rate were higher in the control group compared to the EM-grid group and OPS group (p < 0.05), yet no difference was noted between the control group and cryo-loop group. Development rate and hatching rate of eight cell morulae and blastocysts were all lower in the treatment groups than the control group whilst hatching rate of blastocysts was higher in the control group compared to the groups of EM-grid and OPS (p < 0.05); although the cryo-loop group was shown to be slightly higher than other groups, it was not statistically significant. Conclusions: In the study, we investigate effects of freezing containers on vitrified embryos of respective developmental stages; it was demonstrated that higher developmental rate was shown in more progressed (or developed) embryos with more blastomeres. There was however, no difference in embryonic development rate was shown amongst containers. Taken together, further additional studies are warranted with regards to 1) manipulation techniques of embryos for various vitrification freezing containers and 2) preventive measures against contamination via liquid nitrogen.

The Nobel Prize in Chemistry 2017: High-Resolution Cryo-Electron Microscopy

  • Chung, Jae-Hee;Kim, Ho Min
    • Applied Microscopy
    • /
    • v.47 no.4
    • /
    • pp.218-222
    • /
    • 2017
  • The 2017 Nobel Prize in Chemistry was awarded to the following three pioneers: Dr. Joachim Frank, Dr. Jacques Dubochet, and Dr. Richard Henderson. They all contributed to the development of a Cryo-electron microscopy (EM) technique for determining the high-resolution structures of biomolecules in solution, particularly without crystal and with much less amount of biomolecules than X-ray crystallography. In this brief commentary, we address the major advances made by these three Nobel laureates as well as the current status and future prospects of this Cryo-EM technique.

Structural Studies of Respirasome by Cryo-Electron Microscopy

  • Jeon, Tae Jin;Kim, Ho Min;Ryu, Seong Eon
    • Applied Microscopy
    • /
    • v.48 no.4
    • /
    • pp.81-86
    • /
    • 2018
  • The respiratory chain complex forms a supercomplex (SC) in the inner mitochondrial membrane. This complex facilitates the process of electron transfer to produce the proton gradient used to synthesize ATP. Understanding the precise structure of the SC is considered an important challenge. However, it has not yet been reported. The development of a Cryo-electron microscopy (EM) technique provides an effective way to obtain high-resolution micrographs to determine the high-resolution three-dimensional structure of biomolecules. In this brief review, the currently reported Cryo-EM structures of the mammalian respirasome have been described in order to establish a direction for further research in the respiratory system.

Copper Oxide Spike Grids for Enhanced Solution Transfer in Cryogenic Electron Microscopy

  • Dukwon Lee;Hansol, Lee;Jinwook Lee;Soung-Hun Roh;Nam-Chul Ha
    • Molecules and Cells
    • /
    • v.46 no.9
    • /
    • pp.538-544
    • /
    • 2023
  • The formation of uniform vitreous ice is a crucial step in the preparation of samples for cryogenic electron microscopy (cryo-EM). Despite the rapid technological progress in EM, controlling the thickness of vitreous ice on sample grids with reproducibility remains a major obstacle to obtaining high-quality data in cryo-EM imaging. The commonly employed classical blotting process faces the problem of excess water that cannot be absorbed by the filter paper, resulting in the formation of thick and heterogeneous ice. In this study, we propose a novel approach that combines the recently developed nanowire self-wicking technique with the classical blotting method to effectively control the thickness and homogeneity of vitrified ice. With simple procedures, we generated a copper oxide spike (COS) grid by inducing COSs on commercially available copper grids, which can effectively remove excess water during the blotting procedure without damaging the holey carbon membrane. The ice thickness could be controlled with good reproducibility compared to non-oxidized grids. Incorporated into other EM techniques, our new modification method is an effective option for obtaining high-quality data during cryo-EM imaging.