• 제목/요약/키워드: copper ion

검색결과 503건 처리시간 0.042초

Characterization of Cytosol Acid Protease from Dormant Cyst of Artemia franciscana (Artemia franciscana cyst의 세포내 산성 Protease)

  • 최희선;최경희;류태형
    • Journal of Life Science
    • /
    • 제7권3호
    • /
    • pp.228-233
    • /
    • 1997
  • A thiol protease has been isolated and partially purified from encysted brine shrimp Artemia franciscana using a four-step procedure(filtration, salting out, gel filtration and ion exchange chromatography). The optimum pH of the enzyme for caseinolytic activity was appeared to be 3.0, and the enzymematic activity was stable up to pH 6.0 but lost completely at the pH higher than 8.0. The optimal temperature of the enzyme was appeared to be 35$^{\circ}$C, and ninety percent of the enzyme activity was lost at 45$^{\circ}$C. Various metal ions, e.g., zinc, copper, iron, inhibited the enzyme activity; however, heavy metal chelator, e.g., EDTA, stimulated the enzyme activity. The protease was concluded to be a member of the thiol group protease, since it was inhibited by thiol protease inhibitors and iodoacetate. The protease was also concluded to be a acid protease based on optimum pH.

  • PDF

High Speed Cu Filling Into TSV by Pulsed Current for 3 Dimensional Chip Stacking (3차원 실장용 TSV의 펄스전류 파형을 이용한 고속 Cu도금 충전)

  • Kim, In Rak;Park, Jun Kyu;Chu, Yong Cheol;Jung, Jae Pil
    • Korean Journal of Metals and Materials
    • /
    • 제48권7호
    • /
    • pp.667-673
    • /
    • 2010
  • Copper filling into TSV (through-silicon-via) and reduction of the filling time for the three dimensional chip stacking were investigated in this study. A Si wafer with straight vias - $30\;{\mu}m$ in diameter and $60\;{\mu}m$ in depth with $200\;{\mu}m$ pitch - where the vias were drilled by DRIE (Deep Reactive Ion Etching) process, was prepared as a substrate. $SiO_2$, Ti and Au layers were coated as functional layers on the via wall. In order to reduce the time required complete the Cu filling into the TSV, the PPR (periodic pulse reverse) wave current was applied to the cathode of a Si chip during electroplating, and the PR (pulse-reverse) wave current was also applied for a comparison. The experimental results showed 100% filling rate into the TSV in one hour was achieved by the PPR electroplating process. At the interface between the Cu filling and Ti/ Au functional layers, no defect, such as a void, was found. Meanwhile, the electroplating by the PR current showed maximum 43% filling ratio into the TSV in an hour. The applied PPR wave form was confirmed to be effective to fill the TSV in a short time.

Preparation of Zeolite Coated with Metal-Ferrite and Adsorption Characteristics of Cu(II) (금속 페라이트가 코팅된 제올라이트의 제조와 Cu(II)의 흡착 특성)

  • Baek, Sae-Yane;Nguyen, Van-Hiep;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • 제30권1호
    • /
    • pp.54-61
    • /
    • 2019
  • In this study, a magnetic adsorbent was synthesized by growing ferrite nanoparticles substituted with metals (Me = Co, Mn, Ni) on zeolite 4A for the efficient separation of waste adsorbents present in the solution after the adsorption of Cu(II). The metal ferrite grown on the surface of zeolite was prepared by solvothermal synthesis. Characteristics of the magnetic adsorbent were analyzed by X-ray diffractometer (XRD), scanning electron microscopy (SEM) and physical property measurement system (PPMS). The saturation magnetization of the A type zeolite coated with Co-ferrite (CFZC) was the highest at 5 emu/g and the Cu(II) adsorption performance was also excellent. The adsorption results of Cu(II) on CFZC were well fitted by the Langmuir model at 298 K. Also, the adsorption of Cu(II) on CFZC follows a pseudo-second order kinetic. The Gibbs free energy values (${\Delta}G^0$) ranging from -4.63 to -5.21 kJ/mol indicates that the Cu(II) adsorption is spontaneous in the temeprature range between 298 and 313 K.

Identification and structural analysis of novel laccase genes in Flammulina elastica genome (Flammulina elastica의 유전체 정보기반 신규 laccase 유전자 동정 및 구조 분석)

  • Yu, Hye-Won;Park, Young-Jin
    • Journal of Mushroom
    • /
    • 제19권1호
    • /
    • pp.33-40
    • /
    • 2021
  • The genome sequence of various Flammulina species has recently been reported, thereby revealing a diverse genetic repertoire. In this study, we identified laccase genes and analyzed their structural characteristics in Flammulina elastica (F. elastica) genome. Through genome analysis and bioinformatics approaches, three laccase genes (Fe-lac1, -lac2, and -lac3) were identified, ranging from 1,548 to 1,602 bp in length. These genes contained a copper ion-binding region with ten histidine residues and one cysteine residue and a disulfide bond-forming region with four cysteine residues. Full-length cDNA sequencing analysis revealed that laccase genes contain 12 to 16 introns and signal peptides between 17 and 22 bp in the N-terminus. Structural characterization of the laccase genes identified in this study should help in better understanding the biomass decomposition of F. elastica.

High Speed Cu Filling into Tapered TSV for 3-dimensional Si Chip Stacking (3차원 Si칩 실장을 위한 경사벽 TSV의 Cu 고속 충전)

  • Kim, In Rak;Hong, Sung Chul;Jung, Jae Pil
    • Korean Journal of Metals and Materials
    • /
    • 제49권5호
    • /
    • pp.388-394
    • /
    • 2011
  • High speed copper filling into TSV (through-silicon-via) for three dimensional stacking of Si chips was investigated. For this study, a tapered via was prepared on a Si wafer by the DRIE (deep reactive ion etching) process. The via had a diameter of 37${\mu}m$ at the via opening, and 32${\mu}m$ at the via bottom, respectively and a depth of 70${\mu}m$. $SiO_2$, Ti, and Au layers were coated as functional layers on the via wall. In order to increase the filling ratio of Cu into the via, a PPR (periodic pulse reverse) wave current was applied to the Si chip during electroplating, and a PR (pulse reverse) wave current was applied for comparison. After Cu filling, the cross sections of the vias was observed by FE-SEM (field emission scanning electron microscopy). The experimental results show that the tapered via was filled to 100% at -5.85 mA/$cm^2$ for 60 min of plating by PPR wave current. The filling ratio into the tapered via by the PPR current was 2.5 times higher than that of a straight via by PR current. The tapered via by the PPR electroplating process was confirmed to be effective to fill the TSV in a short time.

Indigenous Radiosynthesis of [131I]Iodobenzylguanidine ([131I]mIBG) for Neuroblastoma Imaging

  • Nadeem Ahmed Lodhi;Muhammad Irfan;Muhammad Nasir Saddique;Kahkshan Bashir Mir;Naseer Ahmed;Shazia Fatima;Mumtaz Khan;Muhammad Wasim;Samina Roohi
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • 제8권2호
    • /
    • pp.71-76
    • /
    • 2022
  • Indigenous diagnostic dose of 131I-labeled meta-iodobenzylguanidine ([131I]mIBG) was prepared via Cu+ catalyzed isotope exchange reaction generated in situ by sodium metabisulfite for imaging of neuroblastoma tumor. [131I]mIBG was produced in overall 85-90% radiochemical yield. The average amount of radioactivity of [131I]mIBG was 2164 MBq (1998-2331MBq) with an average specific activity > 1000 MBq/mg at the end of synthesis. The radiochemical purity was ≥ 99.9% after purification through Dowex-1 × 8 ion exchange resin (100-150 mesh) at the date of preparation. The stability of [131I]mIBG at concentration 480-555 MBq/mL was > 97% at 4 ℃ after 4 days. The room temperature (25 ℃) stability of [131I]mIBG was > 98% after 24 h. Biodistribution of [131I]mIBG in patient showed uptake in salivary glands, liver, spleen and excreted though urinary bladder. Neuroendocrine medicated uptake into tumor lesion and metastatic sites were noted which strongly correlate with the morphological abnormalities of patient.

Water Quality of Some Spring Waters in Pusan Area (부산시내에 산재하는 몇몇 약수터 약수의 수질)

  • KIM Yong-Gwan;CHO Hyeon-Seo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제18권6호
    • /
    • pp.538-544
    • /
    • 1985
  • This study was carried cut to evaluate the water quality of spring waters in Pusan area(see Fig. 1). In this experiment, twenty-five water samples were collected from 5 stations from December 1983 to August 1984. Range and mean values of constituents of the samples are as follows: pH $5.80{\sim}7.25$, 6.60; water temperature $6.0{\sim}23.0^{\circ}C,\;12.9^{\circ}C$; total residue $33.0{\sim}325mg/l$, 121.2mg/l; alkalinity $4.75{\sim}51.6mg/l$, 24.1mg/l; hardness $9.47{\sim}85.0mg/l$, 30.3mg/l; electrical conductivity $0.495{\sim}2.750{\times}^2{mu}{\mho}/cm,\;1.239{\times}10^2{\mu}{\mho}/cm$;turbidity $0.54{\sim}7.80$NTU, 2.04NTU; $KMnO_4$ consumed $0.51{\sim}8.47mg/l$, 1.96mg/l; chloride ion $4.91{\sim}36.0mg/l$, 12.55mg/l; fluoride ion ND-0.30ppm, 0.08ppm; nitrate-nitrogen ND-8.94mg/l, 1.94m:g/l; nitrite-nirogen ND-0.10mg/l, 0.03mg/l; ammonia-nitrogen ND-0.16mg/l, 0.03mg/l: phosphate-phosphorus ND-0.09mg/l, 0.03mg/l; silicate-silicious $0.42{\sim}22.7ng/l$, 7.96mg/l; copper ND-10.5ppb, 2.46ppb; lead ND-22.7ppb, 3.54ppb; zinc ND-103ppb, 21.33ppb; iron $20.3{\sim}2,800ppb$, 801.72ppb, respectively. Arsenic, cyan, cadmium, manganese, mercury, chrome and phenol were not detected. Total residue, electrical conductivity, turbidity and chloride ion of station 1 (Milrakdong) were higher than others as 178.1mg/l, $2.127{\times}10^2{\mu}{\mho}/cm$, 3.16NTU and 16.32mg/l. The concentration of silicious had a great influence on precipitation. The concentration of fluoride ion of spring waters was lower as 0.08ppm than the criterion for drinking water as 1ppm, while iron was exceed 2.7 times as 801.72ppb.

  • PDF

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • 제15권7호
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

The Study of Dose Change by Field Effect on Atomic Number of Shielding Materals in 6 MeV Electron Beam (6 MeV 전자선의 차폐물질 원자번호와 조사야 크기에 따른 선량변화 연구)

  • Lee, Seung Hoon;Kwak, Keun Tak;Park, Ju Kyeong;Gim, Yang Soo;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제25권2호
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: In this study, we analyzed how the dose change by field size effects on atomic number of shielding materials while using 6 MeV election beam. Materials and Methods: The parallel plate chamber is mounted in $25{\times}25cm^2$ the phantom such that the entrance window of the detector is flush with the phantom surface. phantom was covered laterally with aluminum, copper and lead which thickness have 5% of allowable transmission and then the doses were measured in field size $6{\times}6$, $10{\times}10$ and $20{\times}20cm^2$ respectively. 100 cGy was irradiated using 6 MeV electron beam and SSD (Source Surface Distance) was 100 cm with $10{\times}10cm^2$ field size. To calculate the photon flux, electron flux and Energy deposition produced after pass materals respectively, MCNPX code was used. Results: The results according to the various shielding materials which have 5% of allowable transmission are as in the following. Thickness change rate with field size of $6{\times}6cm^2$ and $20{\times}20cm^2$ that compared to the field size of $10{\times}10cm^2$ found to be +0.06% and -0.06% with aluminum, +0.13% and -0.1% with copper, -1.53% and +1.92% with lead respectively. Compare to the field size $10{\times}10cm^2$, energy deposition for $6{\times}6cm^2$ and $20{\times}20cm^2$ had -4.3% and +4.85% respectively without shielding material. With aluminum it had -0.87% and +6.93% respectively and with lead it had -4.16% and +5.57% respectively. When it comes to photon flux with $6{\times}6cm^2$ and $20{\times}20cm^2$ of field sizes the chance -8.95% and +15.92% without shielding material respectively, with aluminum the number -15.56% and +16.06% respectively and with copper the chance -12.27% and +15.53% respectively, with lead the number +12.36% and -19.81% respectively. In case of electron flux in the same condition, the number -3.92% and +4.55% respectively without shielding material respectively, with aluminum the number +0.59% and +6.87% respectively, with copper the number -1.59% and +3.86% respectively, with lead the chance -5.15% and +4.00% respectively. Conclusion: In this study, we found that the required thickness of the shielding materials got thinner with low atomic number substance as the irradiation field is increasing. On the other hand, with high atomic number substance the required thickness had increased. In addition, bremsstrahlung radiation have an influence on low atomic number materials and high atomic number materials are effected by scattered electrons.

  • PDF

Establishment and application of standard-RSF for trace inorganic matter mass analysis using GD-MS (GD-MS 분석 장비를 활용한 극미량 무기물 질량 분석을 위한 표준RSF 구축 및 응용)

  • Jang, MinKyung;Yang, JaeYeol;Lee, JongHyeon;Yoon, JaeSik
    • Analytical Science and Technology
    • /
    • 제31권6호
    • /
    • pp.240-246
    • /
    • 2018
  • The present study analyzed standard samples of three types of aluminum matrix certified reference materials (CRM) using GD-MS. Calibration curves were constructed for 13 elements (Mg, Si, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Ga, Sn, and Pb), with the slope representing the relative sensitivity factor (RSF). The x- and y-axes of the calibration curve represented ion beam ratio (IBR) and the authenticated value of the standard sample, respectively. In order to evaluate precision and linearity of the calibration curve, RSD and the coefficient of determination were calculated. Curve RSD for every element reflected high precision (within 10 %). For most elements, the coefficient of determination was ${\geq}0.99$, indicating excellent linearity. However, vanadium, nickel, and gallium curves exhibited relatively low linearity (0.90~0.95), likely due to their narrow concentration ranges. Standard RSF was calculated using the slope of the curve generated for three types of CRM. Despite vanadium, nickel, and gallium exhibiting low coefficients of determination, their standard RSF resembled that of the three types of CRM. Therefore, the RSF method may be used for element quantitation. Standard iron matrix samples were analyzed to verify the applicability of the aluminum matrix standard RSF, as well as to calculate the RSD-estimated error of the measured value relative to the actual standard value. Six elements (Al, Si, V, Cr, Mn, and Ni) exhibited an RSD of approximately 30 %, while the RSD of Cu was 77 %. In general, Cu isotopes are subject to interference: $^{63}Cu$ to $^{54}Fe^{2+}-^{36}Ar$ and $^{65}Cu$ to $^{56}Fe-Al^{3+}$ interference. Thus, the influence of these impurities may have contributed to the high RSD value observed for Cu. To reliably identify copper, the resolution should be set at ${\geq}8000$. However, high resolutions are inappropriate for analyzing trace elements, as it lowers ion permeability. In conclusion, quantitation of even relatively low amounts of six elements (Al, Si, V, Cr, Mn, and Ni) is possible using this method.