• 제목/요약/키워드: concrete slab

검색결과 1,724건 처리시간 0.025초

차수벽 콘크리트의 섬유보강 및 팽창제 혼입에 따른 소성수축균열 제어특성에 관한 실험적 연구 (An Experimental Study on Plastic Shrinkage of fiber and Expansive Additive for Face Slab Concrete)

  • 김완영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.679-682
    • /
    • 2005
  • The effects of substituting cement with fiber addition(poly vinyl alcohol), fly ash and Expansive Additive on the control of microcrack and enhanced durability performance of face slab concrete in concrete-faced rockfill dam was studied experimentally The laboratory test results shown that the mixture of fiber containing concrete and of fly ash replacement of concrete to be more effective than expansive additive concrete in the crack control and mechanical performance.

  • PDF

CFS로 보강된 모형 RC 슬래브 교량의 실험적 연구 (An Experimental Study on Half Scale RC Slab Bridges Strengthened with Carbon Fiber Sheet)

  • 심종성;김규선;김경민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.537-542
    • /
    • 1999
  • The design methodologies for carbon fiber sheet(CFS) strengthening of RC structures are not well established yet because the structural behavior of strengthened RC structures is more complex than that of unstrengthened ones. Even though the research for the methods using CFS has beed studied, the strengthening effects and structural behaviors of strengthened structures are not systematized yet. The purpose of this study is to carry out the experimental studies on three kinds of half scale RC slab bridges and to investigate the behavior of RC slab bridges from the experimental results. Typical flexural failure occurs in the non-strengthening slab like general RC slab bridges, and also the flexural failure occurs in the all area strengthened slab with sudden rip-off failure of strengthening material by punching shear. For the case of strip type strengthened slab, flexural failure occurs, with rip-off of second strip at the base of loading point. Strengthening effect on the slab using CFS is that the strength is increased upto 7~15 percent and the crack pattern is changed.

  • PDF

지하이동통로가 구비된 다기능 어도의 안정성 검토 (Stability Analysis of Multi-Functional Fishway with Underground Passage)

  • 이영재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권6호
    • /
    • pp.50-59
    • /
    • 2014
  • 본 논문에서는 경북 구미시 봉곡천에 최근 건설된 다기능어도를 대상으로 SAP2000으로 구조 해석하기 위한 변수를 R/C Slab, R/C+S/C Slab 및 지하이동통로 규격(가로${\times}$세로)을 $1m{\times}0.2m$, $1m{\times}0.4m$, $1m{\times}0.6m$와 유속 0.8m/s, 1.2m/s, 1.6m/s으로 구분하여 해석한 결과와 봉곡천 설계식을 비교하여 안정성을 검토하였다. 봉곡천의 설계식 보다 R/C+S/C Slab 타입이 지하이동통로 출구부는 휨모멘트와 최대응력은 각각 28~54%, 26~50%, 측벽은 24~47%, 17~31%, 상부슬래브인 경우도 10~27%, 4~20% 적게 나타났다. 따라서 최대응력과 휨모멘트가 R/C+S/C Slab 타입이 구조 안정성이 확보되는 것으로 나타났기 때문에 지하통로는 휨모멘트와 최대 응력이 27%, 25%, 측벽은 24%, 15% 상부슬래브는 14%, 10%의 보완이 요구되는 것으로 판단된다. 이러한 결과는 지하이동통로 규격이 봉곡천 규격과 동일한 $1m{\times}0.4m$일 때가 $1m{\times}0.2m$, $1m{\times}0.6m$ 보다 안정성이 가장 유리한 것으로 확인되었다. 또한 해석 및 분석 결과를 근거로 다기능어도 시공 시 기본 자료로 활용이 기대된다.

연속 철근콘크리트 슬래브 교량의 윤하중 분포폭에 관한 연구 (Wheel Load Distribution of Continous Reinforced Concrete Slab Bridge)

  • 신호상;오병환
    • 콘크리트학회지
    • /
    • 제10권4호
    • /
    • pp.135-143
    • /
    • 1998
  • 현행 AASHTO 및 AASHTO LRFD 설계기준에는 차선하중에 대한 윤하중분포폭을 차륜하중에 적용되는 윤하중분포폭의 2배를 적용하도록 규정하고 있다. 이에 반해 국내 도로교 표준시방서에는 차선하중에 대한 윤하중분포폭의 규정은 없는 실정이다. 본 연구에서는 연속 철근콘크리트 슬래브 교량에 대한 윤하중분포폭에 관한 연구를 수행하였다. 연속슬래브 교량의 윤하중분포폭에 영향을 미치는 인자들로는 지간길이, 교량폭, 단부보 및 지점조건이 있다. 이들 각 인자들에 대한 유한 요소 모델의 구성 및 해석을 통하여 연속 철근콘크리트 슬래브 교량의 합리적인 윤하중분포폭의 식을 제안하였다. 본 연구에서 제안된 윤하중분포폭의 식은 현행 도로교 표준시방서에 제시되어 있지 않은 철근콘크리트 연속 슬래브 교량의 보다 정확한 설계 및 합리적인 내하력 산정시 매우 효율적으로 사용될 것으로 사료된다.

수평으로 경사진 박스암거 위 콘크리트 포장 슬래브의 최적 줄눈위치 (Optimal Joint Position in Concrete Pavement Slab over Skewed Box Culvert)

  • 염우성;정호성;연우;손덕수;이재훈;정진훈
    • 한국도로학회논문집
    • /
    • 제15권5호
    • /
    • pp.47-55
    • /
    • 2013
  • PURPOSES : The purpose of this study is to investigate the optimal joint positions which can minimize distresses of concrete pavement containing box culvert with horizontally skewed angles. METHODS : The concrete pavement containing the box culvert with different skewed angles and soil cover depths was modeled by 3 dimensional finite element method. The contact boundary condition was used between concrete and soil structures in addition to the nonlinear material property of soil in the finite element model. A dynamic analysis was performed by applying the self weight of pavement, negative temperature gradient of slab, and moving vehicle load simultaneously. RESULTS : In case of zero skewed angle ($0^{\circ}$), the maximum tensile stress of slab was the lowest when the joint was positioned directly over side of box culvert. In case there was a skewed angle, the maximum tensile stress of slab was the lowest when the joint passed the intersection between side of the box culvert and longitudinal centerline of slab. The magnitude of the maximum tensile stress converged to a constant value regardless the joint position from 3m of soil cover depth at all of the horizontally skewed angles. CONCLUSIONS : More reasonable and accurate design of the concrete pavement containing the box culvert can be possible based on the research results.

보-기둥 접합부의 전단거동에 대한 슬래브 및 횡구속 영향 (Transverse Concinement and Slab Effect on Shear Behavior of Beam-Column Connection)

  • 장극관;서대원;방세용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.419-422
    • /
    • 1999
  • This study was intended to investigate the cyclic behavior of high strength concrete beam-column connection. Four assemblies were designed 2/3 scale beam-column-slab joint and tested. The obtained results are follows. 1) The transverse beams increase the shear resistance and ductility of joint, 2) The slab was contributed to increase of the flexural capacity of the beam, but was not contributed to increase the joint ductility under lateral loads.

  • PDF

수직진동 사용성을 고려한 플렛플레이트 두께 제안 (Proposing the Slab Thickness that Satisfies the Vertical Floor Vibration Criteria for Several Sizes of Flat Plate Floor System)

  • 이민정;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.600-603
    • /
    • 2003
  • The floor thickness in residential buildings may not satisfy the floor vibration criteria even though the thickness is determined by the serviceability requirements in current design provisons. Thus it is necessary to develop the procedure to determine slab thickness that satisfies the floor vibration criteria. In this study provide the methods to determine the slab thickness that satisfies the vertical floor vibration criteria for several sizes of flat plate floor system. Randomness inherent in young modulus of concrete and heel drop intensity was accounted. For this purpose Monte Carlo simulation procedure was adopted.

  • PDF

Analysis of shear lag effect in the negative moment region of steel-concrete composite beams under fatigue load

  • Zhang, Jinquan;Han, Bing;Xie, Huibing;Yan, Wutong;Li, Wangwang;Yu, Jiaping
    • Steel and Composite Structures
    • /
    • 제39권4호
    • /
    • pp.435-451
    • /
    • 2021
  • Shear lag effect was a significant mechanical behavior of steel-concrete composite beams, and the effective flange width was needed to consider this effect. However, the effective flange width is mostly determined by static load test. The cyclic vehicle loading cases, which is more practical, was not well considered. This paper focuses on the study of shear lag effect of the concrete slab in the negative moment region under fatigue cyclic load. Two specimens of two-span steel-concrete composite beams were tested under fatigue load and static load respectively to compare the differences in the negative moment region. The reinforcement strain in the negative moment region was measured and the stress was also analyzed under different loads. Based on the OpenSees framework, finite element analysis model of steel-concrete composite beam is established, which is used to simulate transverse reinforcement stress distribution as well as the variation trends under fatigue cycles. With the established model, effects of fatigue stress amplitude, flange width to span ratio, concrete slab thickness and shear connector stiffness on the shear lag effect of concrete slab in negative moment area are analyzed, and the effective flange width ratio of concrete slab under different working conditions is calculated. The simulated results of effective flange width are compared with calculated results of the commonly used specifications, and it is found that the methods in the specifications can better estimate the shear lag effect in concrete slab under static load, but the effective flange width in the negative moment zone under fatigue load has a large deviation.

벽체-슬래브 구조시스템에서의 슬래브의 커플링 효과 (A Coupling Effect of the Slab in Wall-Slab Structural Systems)

  • 장극관;천영수;서대원
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.417-422
    • /
    • 2001
  • This paper is investigated the coupling effect in slab-wall structural system. An experimental investigation of reinforced concrete wall-slab structures were peformed. For the purpose of this study slab-wall substructures of an apartment building were chosen. And two specimens with different aid ratios have been tested. There were subjected to reserved cyclic loading, consistent with coupling action, with increasing imposed inelastic deformations. From. the result of this test, 1) in slabs, the coupling stress are not uniform across the width, 2) cracks are tending to be concentrated in the regions near the inner edges of the walls, 3) the effective width used in previous theoretical or model studies may not be enough.

  • PDF

강섬유를 보강한 슬래브-기둥 시스템의 거동에 관한 연구 (The Effects of Steel Fibers on the Behavior of Slab-Column System)

  • 최응규;강경수;김묵한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.553-558
    • /
    • 1998
  • Two-way slab-column specimens were tested under monotonic loading increased up to punching shear failure to investigate the beneficial effects of fiber-reinforced concrete. The parameters for experiments are the placement of fibers within the immediate column region, the placement on the entire surface of the slab, and no placement of fibers. The effects of these parameters on the punching shear capacity, negative moment cracking. and stiffness of the two-way slab specimens were studied. According to the results the addition of steel fibers in the slab around the column results in a significant improvement in the performance including the increase of punching shear resistance, greater post-cracking stiffness and smaller crack width at service load levels.

  • PDF