• 제목/요약/키워드: concrete resistance

검색결과 2,932건 처리시간 0.025초

고성능 감수제와 방동제를 사용한 콘크리트의 초기 동해 저항성능 (Frost Resistance of Concrete with Antifreezers and Superplasticizers at Early age)

  • 박찬규;한광재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.195-200
    • /
    • 2002
  • In this paper, the effects of type and content of antifreezer on the frost resistance of concrete at early age were investigated. For this purpose, 4 types of antifreezer and 2 types of superplasticizer were selected, and based on the strength recovery ratio, the frost resistance of concrete was estimated. The optimum concrete mixes were also produced when the curing temperatures were -5 and -10$\{circ}{c}$.

  • PDF

고강도 콘크리트의 동결융해 저항 특성에 관한 실험적 연구 (An ExperimentalStudy on the Freeze-Thaw Resistance Properties of High Strength Concrete)

  • 송태경;이남주;김제원;설광욱;정환욱;부척량
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.456-461
    • /
    • 1997
  • The purpose of this experimental study are to produce a durable concrete and to investigate the various factors that can deteriorate the concrete when freezing and thawing activity. Among the various factors that can influence the frost resistance of concrete, this study examined mainly the relationship of the frost resistance with the water-cement ratio, admixture and admixture replacement ratio and propose the available water-cement ratio, admixture and admixture replacement ratio.

  • PDF

재생골재를 이용한 식재용 콘크리트의 동결융해저항성에 관한 연구 (A Study on the Freeze-Thaw Resistance of Planting Concrete Using Recycled Aggregate)

  • 이상태;전충근;김경민;최청각;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.233-236
    • /
    • 2003
  • This study is intended to investigate the resistance of frost damage of concrete for planting, which recycled aggregate is used, by freezing in air and thawing in water. According to the results, if AE agent of 0.005% is mixed in making concrete for planting, it is thought that the resistance of frost damage is guaranteed in winter because concrete for planting is not under severe freezing and thawing function, but under natural weather action.

  • PDF

Characteristics of high performance reinforced concrete barriers that resist non-deforming projectile impact

  • Dancygier, A.N.
    • Structural Engineering and Mechanics
    • /
    • 제32권5호
    • /
    • pp.685-699
    • /
    • 2009
  • Current research and development of high performance concrete, together with study of phenomena that are pertinent to impact resistance, have lead to a new generation of barriers with improved properties to resist impact loads. The paper reviews major properties and mechanisms that affect impact resistance of concrete barriers as per criteria that characterize the resistance. These criteria are the perforation limit, penetration depth and the amount of front and rear face damage. From the long-known, single strength parameter that used to represent the barriers' impact resistance, more of the concrete mix ingredients are now considered to be effective in determining it. It is shown that the size and hardness of the aggregates, use of steel fibers and micro-silica have different effects on performance under impact and on the resistance. Additional pertinent phenomena, such as the rate and size effects, confinement and local versus global response, are pointed out with their reference to possible future developments in the design of impact resisting concrete barriers.

알카리활성 슬래그 콘크리트의 동결융해 저항성 (Resistance to Freezing and Thawing of Alkali-Activated Slag Concrete)

  • 문재성;조아람;심재일;양근혁
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.105-106
    • /
    • 2011
  • The present tests examined the resistance to freezing and thawing of alkail-activated (AA) slag concrete having compressive strength between 30~56 MPa. To enhance the compressive strength and resistance to freezing and thawing of AA slag concrete, Na ions were used for an activator. Test results revealed that the resistance to freezing and thawing of AA slag concrete is comparable to that of cement concrete when compressive strength is more than 50 MPa.

  • PDF

내한촉진제를 이용한 시멘트 모르터의 동결 및 강도특성에 관한 연구 (A Study on the Freezing and Strength Properties of Cement Mortar using Accelerator for Freezing Resistance)

  • 박상준;김동석;원철;이상수;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1267-1272
    • /
    • 2000
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. These are problems on cold weather concrete. One of the solution methods for resolving these problems has been to reduce the freezing temperature of concrete by the use of chemical admixtures called Accelerators for freezing resistance. Therefore, in this study, we executed freezing temperature of mortar, setting and strength properties with using water reducing accelerator and accelerators for freezing resistance which are producted internationally. As a result of this experiment, the freezing temperature of mortar is lower and the setting property is promoted when the admixing content of accelerators for freezing resistance is increased. Moreover, the compressive strength of mortar used accelerators for freezing resistance represented the result which is similar with result of analysis of compressive strength increase with using logistic curve formula, but in the case of plain and using water reducing accelerator, there is no relation between logistic curve formula, maturity and compressive strength.

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

콘크리트 표면도장에 의한 내구성증진 효과 (Effect of Concrete Coating Materials for the Improvement of Concrete Durability)

  • 문한영;김성수;안태송;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.433-436
    • /
    • 1999
  • Long-term durability of the reinforced concrete structures exposed to marine environment deteriorates seriously by the attack of the chloride ion from see water results in corrosion of steel reinforcement in concrete. Their coating effect is aluminum oxide-isocyanate-based coating material, resistance of chloride penetration, carbonation and freezing and thawing resistance were compared to acryl-based coating material and sealer type o waterproofing material. Aluminum oxide-isocyante-based and acryl-based coating material show higher resistance to chloride penetration and carbonation than the sealer type do waterproofing material and aluminum oxide-isocyanate-based coating resist about 99% of chloride penetration. Resultants to the accelerated test for freezing and thawing, coating concrete show higher resistance than non-coating concrete, respectively.

  • PDF

고내구성콘크리트의 염해저항성에 관한 실험적 연구 (An Experimental Study on the Salt Damage Resistance of High Durable Concrete)

  • 윤재환;정재동
    • 한국건축시공학회지
    • /
    • 제3권3호
    • /
    • pp.73-81
    • /
    • 2003
  • In this paper, salt damage resistance of high durable concrete was tested. High durable concrete was made by using low water cement ratio, chemical admixture called super-durable admixture and mineral admixtures such as fly-ash, ground granulated blast-furnace slag, silica fume. Two kinds of salt damage resistance test were carried out. One method is chloride ion penetration test(ASTM C1202), and the other one is depth of chloride penetration test in saline solution. Test results were as followers: 1) The depth of chloride ion penetration increased exponentially as water cement ratio was increased and time passed. 2) Super-durable admixture had little effect on the improvement of salt damage resistance of concrete. 3) Silica fume and ground granulated blast-furnace slag were effective on salt damage resistance because of pozzolanic reaction, but fly-ash had a little effect.

콘크리트 강도 조기 판정기의 개발에 관한 연구 (2) 전기 저항법을 이용한 모르타르의 압축강도에 관한 실험적 연구 (The Study for Development on Earlier Evaluation Instrument of Strength of Concrete -An Experimental Study on Compressive Strength of Mortar Using Resistance Method-)

  • 이도헌;윤상천;김화중;박정민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.441-446
    • /
    • 1994
  • In this study proposed to rapid and simple test method for early decision of quality of concrete. As the this paper is experimental study for compressive strength of mortar using resistance method, the obtained results are summarized as follow ; $\circled1$ The resistance ratio was decreased as the incement of water-cement ratio $\circled2$ The compressive strength presented to the tendency of increment as resistance ratio is increaing