• Title/Summary/Keyword: classroom lighting

Search Result 27, Processing Time 0.028 seconds

A Study on the Renovation of Ordinary Classroom into Computer Laboratory (보통교실(普通敎室)을 개조(改造)한 컴퓨터실(室) 계획(計劃)에 관한 연구(硏究))

  • Joo, Young-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1994
  • It is time to put our top priority on the computer education to cope with rapid chage in technology and expansion of information. With 6th educational reform plan, from 1995 computer courses will be offered as elective subjects in the most of middle schools. However, detail planning for training of computer courses will be offered as elective subjects in the most of middle schools. However, detail planning for training of computer teachers and providing facilicles for computer education hasn't been adequately prepared yet, This will bring about confusion in computer education. The purpose of this study is to propose how to renovate the ordinary classroom into computer classroom. Followings are the suggestions for the educational specification for the renovated computer classroom for middle school in the urban area. 1) Purpose of computer classroom, 2) Size of computer classroom, 3) Curriculum design and class hour, 4) Facilities, 5) Environments, 6) Equipment and media(lighting and electric system, acoustical treatment, cooling/heating and ventilation system), 7) Activity area(Teacher workstation, Student workstation, Support area, Display surface). For the promotion of computer education, the legal, financial and administrative supports by concerned authorities should be established ahead of discussing the contents of computer education.

  • PDF

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

Interior Planning for Classrooms in Kindergarten (유치원 보육실 실내환경계획 방향에 관한연구)

  • 황연숙;박희진
    • Korean Institute of Interior Design Journal
    • /
    • no.15
    • /
    • pp.62-68
    • /
    • 1998
  • Children develop in direct relation and response to their physical environment, The purposes of this study were to investigate the current interior design conditions of classrooms in kindergarten and to provide interior planning guidelines for children's behavioral and developmental improvement and better educational environment. Data were collected through interview and questionnaire survey. The sample included 239 teachers who were employed in 23 kindergartens located in Pusan. The data were analyzed by using SPSS-PC. The major findings were as follows; (1) Wood and wallpapers which provide various colors and patterns are recommendable as a classroom finish rather than paint which looks monotonous. (2) Teachers preferred 7 or 8 activity centers in classroom and furniture or partition is the best when dividing space. (3) Classroom should be large enough to locate various types of furniture that designed based on child-size and objects to store. (4) Activity centers should be lit by different types of task lighting such as floor lamp and backer to provide sufficient level of light.

  • PDF

Objective Evaluation of Learning Performance according to the Color Temperature of LED Illumination (LED 조명의 색 온도에 따른 학습 성과의 객관적 평가)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.2
    • /
    • pp.25-33
    • /
    • 2011
  • This study performs the objective evaluation on simple comparison and calculation works by students under LED illumination conditions according to three types of color temperatures (7000K, 5000K, 3000K) in the classroom, Since the objective of this study is to develop an electric lighting conditions suitable for students in the classroom, the learning performance under three types of LED illumination conditions were analyzed. The 4 kinds of simple tests concerning with learning performance were developed and test results under natural light and LED illumination by 3 types of color temperatures were analyzed. There were differences by t-test in most cases among simple experiment results of different illumination conditions ($p{\leq}.05$). It was confirmed that illumination condition plays an important role when students simply compare words or perform arithmetic calculations. The experimental results of this study might be applied to designing better luminous environment.

  • PDF

Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom (교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가)

  • Kwon, Daehyeok;Lee, Jae-Ro;Oh, Juseok;Wi, Seunghwan;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.28 no.3
    • /
    • pp.224-232
    • /
    • 2017
  • Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.

A Energy Saving and Illuminance of a Classroom due to the arrangement of luminaires (조명기구의 배치에 따른 교실의 조도와 에너지 절약)

  • Kim, Lee-Doo;Oh, Se-Young;Park, Hee-Doo;Shin, Jong-Yeol;Lee, Soo-Won;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2417-2419
    • /
    • 1999
  • Among educational environment, lighting's role is getting more important since it improves the visual tasks, capability of work, and it help to build both balanced mind and body. Also, since students spend most of their time inside rather than outside, students need appropriate illuminance everyday. If optimum illuminance, the color rendering properties and controlled distribution of lighting is given, people can decrease the fatigue of eyes, recover their health, and also, people can maximize their efficiency of work. In this paper, their is a comparison between the real illuminance and illuminance distribution due to the uniformity ratio of 2 or 3 dimensions by simulation.

  • PDF

A survey of actual conditions on the Kindergarten attached to colleges through actual measurement (실측을 통한 대학부설 유치원의 실태분석)

  • 석주영
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.10a
    • /
    • pp.51-55
    • /
    • 1994
  • This study was attempted to investigate the facilities and environments of kindergarten attached to colleges, and ultimately to make up the adequate environment of for children. For these purposes, investigators directly visited 6 kimdergartens attached to colleges, and actually measured the facilities and equipments of these kindergartens. Concretely, our invetigators analyzed the actual conditions of kindergarten attached to colleges contering around the lighting and illumination of classroom, corridor, hall, toile room, dining room, and furnitures, closing materials of the floor, wall, ceiling.

  • PDF

Evaluation of Concentration and Visual Discrimination according to the Color Temperatures of LED Illumination (LED 조명의 색온도에 따른 집중도 및 시각적 변별력 평가)

  • Lee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.3
    • /
    • pp.23-33
    • /
    • 2011
  • This study investigates the evaluation on simple comparison and seeking hidden figures works under LED illumination conditions according to three types of color temperatures (7000K, 5000K, 3000K) in the classroom, Since the objective of this study is to develop an electric lighting conditions suitable for students in the classroom, the performance of concentration and visual discrimination by students under three types of LED illumination conditions were analyzed. The 4 kinds of simple tests concerning with concentration and 2 types of tests for visual discrimination were developed, and test results under natural light and LED illumination by 3 types of color temperatures were analyzed. There were differences on concentration as well as visual discrimination performance in most cases by t-test ($p{\leq}0.05$). For further analysis among three types of color temperatures and natural light, ANOVA tests were performed. The test results shows that illumination condition plays an important role when students try to concentrate on simple comparison of characters, figures or colors and seek hidden figures. The experimental results of this study might be applied to designing better luminous environment.

  • PDF

A Study on the Evaluation of Campus Outdoor Spaces as a Regional Hub (지역거점으로서의 캠퍼스 외부공간 디자인 평가에 관한 연구)

  • Lee, Eul Gyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.4
    • /
    • pp.33-40
    • /
    • 2016
  • The campus outdoor space in each city is a very important space for students and local residents. Especially, for students, indoor space such as classroom is the main place to learn knowledge. But the outdoor space provides an opportunity to interact with people in other sectors and it also gives an opportunity that can make students sense the flow of the times. Moreover, students have the opportunity to integrate knowledge of the other fields in the outdoor space. The campus also provides an important resting place for residents. Therefore the campus should be convenient for both local residents and students, and should be designed to let students and local residents communicate with each other in outdoor space. This study attempts to identify the problems of the outdoor space in such a point. The high scores of campus evaluation indexes are as follows: First, the lighting in the favorite space and installing seats in a green space of the vestibule get the highest score. Also, separation of a sidewalk and a roadway, the ease of holding events, simple food and beverage near the entrance, the interacting place of people, the resting place near the porch in cold winter, the lighting in a bus stop and parking lot also get good evaluations.

Renovation of Closed School Using Sustainable Method - From Closed School to Artist Studio Complex - (환경친화적인 리노베이션 기법을 적용한 폐교의 재활용 - 폐교를 이용한 복합 예술작업공간 설계 -)

  • Hong, Seung-Shin;Rieh, Sun-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.4
    • /
    • pp.95-102
    • /
    • 2002
  • The purpose of this study is to renovate a closed school to a artist studio complex applying sustainable principles and methods. Through the case study, the principle and methods of sustainable renovation is investigated and following strategies are extracted as a frame of renovation. First, atrium space with thermal mass using existing wall is proposed as a public gathering space. Second, light shelves for effective lighting and shading device for protecting and allowing sun light is proposed to renovate existing classroom. Third, double skin system is proposed with reflection pool to activate heating and ventilation for passive solar as well as passive cooling. Finally, simulation programs such as energy-10 and Form-Z is used to confirm the validity of the sustainable design.