Evaluation of Indoor Thermal Environment according to Type and Color of Blinds Installed in the Classroom

교실에 설치된 블라인드의 유형과 색상에 따른 실내 온열환경 평가

  • Kwon, Daehyeok (School of Architecture, Soongsil University) ;
  • Lee, Jae-Ro (School of Architecture, Soongsil University) ;
  • Oh, Juseok (School of Architecture, Soongsil University) ;
  • Wi, Seunghwan (School of Architecture, Soongsil University) ;
  • Kim, Sumin (School of Architecture, Soongsil University)
  • Received : 2017.06.15
  • Accepted : 2017.07.17
  • Published : 2017.07.25

Abstract

Building energy saving have been put effort in a long time since buildings consume about 40.6% of total energy use, where heating, cooling and electrical lighting requirement results in energy consumption of building significantly. The window is an important part of building envelope, it usually brings a certain heat load from solar radiation while it allows light passing through, and properly leads to overheating in summer, hence the cooling load increase sand cause of thermal uncomfortable factor. The purpose of this study was to evaluate internal shade performance according to color and materials. There is growing interest in improving the sense of comfort among students who spend most of their time in the classroom. The study examined thermal environment and light environmental performance according to the color and materials of internal blinds to the school classroom. The results of this study were as follows; Among wooden blinds, aluminium blinds, and polyester blinds, the aluminium blinds were most excellent. In addition, among white blinds, light brown blinds, dark brown blinds, the light brown were most excellent.

Keywords

References

  1. 김태중, 강재식, 박준석. 2014. 실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구. 한국태양에너지학회 논문집 34(5): 89-99. https://doi.org/10.7836/kses.2014.34.5.089
  2. 박은미, 최동호. 2016. 하절기 내측 블라인드의 유형별 일사차폐성능 비교 실측연구. 한국태양에너지학회 논문집 36(4): 1-9. https://doi.org/10.7836/kses.2016.36.4.001
  3. 윤여범, 김동수, 박장우, 이광호. 2013. 내․외부 블라인드 운영방법과 창호성능에 따른 건물에너지 성능 평가 연구. 대한건축학회 논문집 29(7).
  4. 이선영, 김상진. 2017. 실태조사를 바탕으로 한 어린이집 시환경 개선방안 연구. 대한건축학회 논문집 19(2).
  5. 이윤정, 김정태. 공동주택 거주자의 실내 차양장치 사용 행태에 관한 연구. 한국태양에너지학회 논문집 34(3): 12-20. https://doi.org/10.7836/kses.2014.34.3.012
  6. 정철운, 정은정, 김재수. 2007. 차양설치에 따른 실내 일조조건의 변화에 관한 연구. 대한건축학회 학술발표대회 논문집 - 계획계 27(1): 949-952.
  7. 최병보, 전현식, 윤석일, 김석환, 이상진, 김수민. 2012. 복합문화시설내 공간 구조에 따른 일조와 일사가 실내온열환경에 미치는 영향. 설비공학논문집 24(11): 751-758. https://doi.org/10.6110/KJACR.2012.24.11.751
  8. 홍현진, 박범주, 유슬기, 김수민. 2013. 학교 옥외 공간내 식재된 수목의 차양효과에 따른 여름철 실내 온열 환경 및 빛환경 분석. 한국생활환경학회지 20(5): 663-670.
  9. 황덕수, 이경희. 2011. 블라인드 설치 위치에 따른 실내 열환경 변화에 관한 연구. 한국태양에너지학회 논문집 31(5): 113-118. https://doi.org/10.7836/kses.2011.31.5.113