• Title/Summary/Keyword: chopping

Search Result 183, Processing Time 0.032 seconds

Effects of Small Scale Post-Harvest Facility and Hygiene Education on the Level of Microbial Safety in Korean Leeks Production (영양부추 생산농가의 소규모 수확후 처리시설 적용과 위생교육에 따른 미생물학적 안전성 향상 효과)

  • Kim, Se-Ri;Kim, Jin-Bae;Lee, Hyo-Sup;Lee, Eun-Sun;Kim, Won-Il;Ryu, Song-Hee;Ha, Jihyung;Kim, Hwang-Yong;Ryu, Jae-Gee
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.249-257
    • /
    • 2015
  • The purposes of this study were to develop a small scale post-harvest facility, and consequently to evaluate the effects of applying the facility along with hygiene education on the level of microbial safety in Korean leeks production. A total of 135 samples were collected at three Korean leeks farms in Yangju, Gyeonggi province. Food safety indicators (Aerobic plate count (APC), coliform count, and Escherichia coli) and foodborne pathogens (E. coli O157:H7, Salmonella spp., Staphylococcus aureus, Listeria monocytogenes, and Bacillus cereus) on/in the samples were assessed. The microbial load measured as APC with harvesting tools such as comb, chopping board, and knife, at the farms where the small scale post-harvest facility had been operated (Farms A and B) was lower than that at another farm having no post-harvest facility (Farm C) by 1.44~2.33 log CFU / $100cm^2$. Moreover, the chopping board from Farm C was observed being contaminated with B. cereus at 6.03 log CFU / $100cm^2$. The coliform counts from the samples increased by 0.57~1.89 log CFU/g after leeks was submerged in ground water for washing. E. coli was recovered from leeks, soil, and the ground water used in the washing process, while no E. coli O157:H7, Salmonella spp., and L. monocytogenes was detected. Our results indicated that the small scale post-harvest facility developed in this study as well as the hygiene education played an important role in enhancing the level of microbial food safety in the leeks production environment. However, a disinfection technique could be needed during the washing step in order to prevent a potential contamination.

A Correlation Study of Surveillance Data and ATP Bioluminescence Assay for Verification of Hygienic Status in Major Hotels in Seoul (서울 시내 주요 호텔의 위생실태 조사와 ATP 결과의 상관 분석 연구)

  • Kim, Bo-Yeon;Song, Ha-Young;Park, In-Sook;Kim, Yong-Su;Lee, Yu-Si;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.3
    • /
    • pp.277-284
    • /
    • 2009
  • Currently food-borne disease is being increased at outdoor food services including hotels and restaurants. Speedy and convenient practical monitoring techniques to determine hygienic conditions are needed. This study was designed to verify correlation of direct ATP (Adenosine Tri-Phosphate) examination method using ATP bioluminescence and surveillance with check-list by inspector. Hygienic status of personal hygiene (hands), kitchen utensils (knives, chopping boards, kitchen towels, cap openers, food storage containers, and blade of slice machines), facilities and equipments (refrigerator handles, worktables, and sinks) in five major hotels in Seoul were examined. The result of personal hygiene of hotels was relatively better than other inspection items (46.6 points in personal hygiene, 40.2 points in kitchen utensils, 40.3 points in facilities & equipments). In ATP inspection, kitchen utensils and facilities & equipments were relatively clean comparing with personal hands data ($40.8{\pm}6.77\;RLU/cm^2$). After correlation analysis of surveillance in hygienic status points and ATP value, all results showed negative and high correlation. The surveillance data and ATP results investigating personal hygiene, kitchen utensils and facilities & equipments were highly correlated. The ATP examination method which shows real-time identification could be considered as an appropriate method to alternate current check-list dependent safety management in food services including hotels.

Microbiological Hazard Analysis of Foodservice Facilities and Equipment at Kindergarten Foodservice Establishments (유치원 급식시설.설비에 대한 미생물학적 위해분석)

  • Lee, Hye-Yeon;Bae, Hyun-Joo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.10
    • /
    • pp.1457-1465
    • /
    • 2009
  • This study was conducted to analyze the food safety management practices and to provide data that could be used to improve food safety management at kindergarten foodservice establishments in Daegu and Gyeongbuk province. Microbiological hazard analysis was conducted from May to July, 2008 at the four foodservice establishments. A total (20 items) of foodservice facilities, cooking utensils, and equipment were tested about total plate counts, coliforms, E. coli, Staphylococcus aureus, Salmonella spp., and Listeria monocytogenes. The microbiological detected levels were higher than the critical limits for prepreparing and cooking knives, chopping boards, working tables (both prepreparing and cooking), refrigerator (inside wall), bart, basket, and tray. E. coli, Salmonella spp., and Listeria monocytogens were not detected in any samples. However, Staphylococcus aureus were detected in rubber gloves for cooking and trench in the bottom at one foodservice establishment. In conclusion, these results suggest that a prerequisite programs guideline should be provided to improve the food safety levels at kindergarten foodservice establishments and the foodservice manager must maintain proper food safety technique for foodservice facilities, cooking utensils, and equipment at kindergarten foodservice establishments to prevent cross-contamination and spread of foodborne pathogens.

Changes of Contamination Level of Listeria spp. during the Processing Environments in Kimbab Restaurants (김밥 전문음식점 내 작업 환경에서의 Listeria spp. 오염의 변화)

  • Kim Ji-Yeon;Kwon Ill-Kyong;Ha Seung-Yeul;Hong Chong-Hae
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.4
    • /
    • pp.232-236
    • /
    • 2005
  • This study was performed to find out the patterns of Listeria spp. contamination during Kimbab preparation at the specialized restaurants. Samples were collected from ingredients, containers, equipments, and environments from two Kimbab restaurants from July through September, 2004. Isolation rate of Listeria spp. was $43.2\%$ among 264 samples. Strains isolated were Listeria innocua $35.9\%$, L. murrayi $6.8\%$, and L. grayii $0.3\%$. No L. monocytogenes was detected. Contamination level of ingredients, containers, equipments, and Kimbab sampled during afternoon was all significantly higher than the samples collected during morning(P < 0.05). The most influencing factor of contamination was improper handling or no disinfection procedures during Kimbab preparation. Safety controls are recommended as follows; prevention of cross-contamination during ingredients Preparation, temperature control for ingredients and Kimbab during holding, cleaning and disinfection of chopping boards and knives during preparation processing, and frequent changes of disposable gloves. Kimbab restaurants should recognize the importance of safety control using the Good Hygienic Practices.

Image Processing Technology for Analyzing the Heating State of Carbon Fiber Surface Heating Element (탄소섬유 면상발열체의 발열 상태 분석을 위한 영상처리 기술)

  • Cho, Joon-Ho;Hwang, Hyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.683-688
    • /
    • 2018
  • In this study, we analyzed the heat generation state of a flat heating element by using image processing technology in conjunction with carbon fiber. The flat heating element is manufactured by chopping the carbon fiber to a small size and bonding it again using a dispersing agent. The solution of carbon fiber, bound together using the dispersant, is then filtered onto the nonwoven fabric. The last step is to obtain flat carbon fibers in the form of nonwoven fabrics for the purpose of drying the filtered carbon fibers. In the flat heating element, electricity may be applied to the carbon fiber on the surface produced in this manner. In this study, the flat heating element was analyzed by four methods. The analysis of the heat generation characteristics and heating rate of the flat heating element confirmed that the fabricated sheet heating element corresponds to a normal army. The analysis of the insulation coating and flat heating element module, which can be used for actual product manufacturing, involves two dimensional image analysis using image processing technology. The thermal image analysis of the flat heating element is a programming technique that not only analyzes the heat generation state in both two and three dimensions, but also displays the upper and lower 15 to 20% ranges of temperature corresponding to the heat generation in the image. In the final analysis, it is possible to easily find the erroneous part in the manufacturing process by directly showing the state of the fabricated flat heating element on the screen. By combining this image analysis method of the flat heating element with the existing method, we were able to more accurately analyze the heat generation state.

A Three-phase Current-fed DC-DC Converter with Active Clamp (연료전지용 3상 전류형 능동클램프 DC-DC 컨버터)

  • Cha, Han-Ju;Choi, Jung-Wan;Yoon, Gi-Gab
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.456-464
    • /
    • 2007
  • This paper proposes a novel three-phase current-fed active clamp DC-DC converter for fuel cells. A single common active clamp branch is used to limit transient voltage across the three-phase full bridge and to realize zero-voltage switching(ZVS) in all switches. To apply for the power generation system current-fed type has been combined with the three-phase power conversion system. The proposed approach has the following advantages: an increase (by a factor of three) of input current and output voltage chopping frequencies; lower RMS current through the inverter switches with higher power transfer capability; reduction in size of reactive later components and the power conditioning system; better transformer utilization; increase of the system reliability. Therefore, the proposed three-phase current-fed active clamp DC-DC converter is appropriate for the boost type DC-DC converter for fuel cells and also applicable for the photovoltaic and battery charge system. The paper details the analysis, simulation and hardware implementation of the proposed system. Finally, experimental results with the proposed PWM strategy demonstrate the feasibility of the proposed scheme on a 500W prototype converter.

Studies on the Processing and Utilization of Seaweeds - Studies on the Processing of Sea Mustard Jam- (해조류의 가공 및 이용에 관한 연구 -미역쨈의 제조에 관한 연구-)

  • CHA Yong-Jun;LEE Eung-Ho;PARK Du-Cheon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.21 no.1
    • /
    • pp.42-49
    • /
    • 1988
  • In order to utilize sea mustard, Undaria pinnatifida, effectively. sea mustard jam was prepared by use of physical properties of polysaccharides, mainly alginic acid and then its chemical composition, nutritive qualifies and the stability of pigments were examined. Suitable processing condition for sea mustard jam was as fellows : as the first stage, fresh sea mustard was scalded for 20 sec at $85^{\circ}C$ and dried sea mustard was dipped for 20 min in cold water for rehydration, then both sea mustards were treated by draining and chopping. Next, after adding 4 fold of $0.5\%\;K_2HPO_4$ solution to weight of chopped sea mustards, the mixed solutions were agitated for 15 min at $95^{\circ}C$, and gelated sea mustards were filterated by pressing. Flow characteristics of those sea mustard jam were regarded mixed type having pseudoplastic type and yield stress. Judging from sensory evaluation, adding $0.375\%$ of saccharin, $2\%$ of sorbitol, $0.25\%$ of citric acid and $0.5\%$ of powder of roasted soybean to sea mustard jam were suitable for enhancing taste and flavor of product. Chemical composition of products were scarcely changed throughtout processing. Jam processed by fresh sea mustard was better than dried one in contents of chlorophyll and total carotenoid pigments. In fatty acid composition, polyenoic acids of $C_{18:3},\;C_{20:4},\;C_{20:5},\;C_{22:6}$ were held high contents as known to have lowering function of cholesterol contents. It was presumed that dominant contents in free amino acids such as lysine, alanine, glutamic acid and organic acids such as citric acid, oxalic acid, $\alpha-ketoglutaric$ acid, lactic acid and succinic acid held important role for the flavor of sea mustard jam.

  • PDF

Uncooled Metallic Thin-film Thermopile Infrared Detector (비냉각 금속 박막형 열전퇴 적외선 검지기)

  • Oh, Kwang-Sik;Cho, Hyun-Duk;Kim, Jin-Sup;Lee, Yong-Hyun;Lee, Jong-Hyun;Lee, Jung-Hee;Park, Se-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.5-12
    • /
    • 2000
  • Uncooled metallic thin-film thermopile infrared detectors have been fabricated, and the figures of merit for the detectors were examined. The hot junctions of a thermopile were prepared on a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-membrane which acts as a thermal isolation layer, the cold junctions on the membrane supported with the silicon rim which functions as a heat sink, and Au-black was used as an infrared absorber. Infrared absorbance of Au-black, which strongly depends on the chamber pressure during Au-evaporation and its mass per area, was found to be about 90 % in the wavelength range from 3${\mu}{\textrm}{m}$ to 14${\mu}{\textrm}{m}$. Voltage responsivity, noise equivalent power, and specific detectivity of Bi-Sb thermopile infrared detector at 5 Hz-chopping frequency were about 10.5V/W, 2.3 nW/Hz$^{1/2}$, 및 $1.9\times10^{7}$ cm.Hz$^{1/2}$/w at room temperature in air, respectively.

  • PDF

Drying Rate and Physicochemical Characteristics of Dried Ginseng Root at Different Temperature (열풍건조온도에 따른 수삼건조속도 및 건조수삼의 이화학적 특성)

  • 하대철;이종원;도재호;박채규;류기형
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.4
    • /
    • pp.741-746
    • /
    • 2004
  • Drying of raw ginseng root down to 35% moisture content required for extrusion process. There were two kinds of pre-treatments of raw ginseng root which were chopping and whole-root ginseng before frying at 80, 100 and 12$0^{\circ}C$. Drying rate and physicochemical properties of dried ginseng were evaluated to determine optimum drying temperature for extrusion process. Drying time at 8$0^{\circ}C$ to decrease to 35% moisture was 6.5 hr and ginsenoside content in dried ginseng at 8$0^{\circ}C$ was lower than that of dried ginseng at 100 and 12$0^{\circ}C$. Drying time at 100 and 12$0^{\circ}C$ to decrease to 35% moisture was 5.5 and 3.5 hr and redness of dried ginseng powder was 5.20 and 7.23 respectively. Browness and redness of dried ginseng extract from 75% ethylene were significantly increased with the increase in drying temperature. Ginsenosides Rb1, Rb2, Rc, Rd, Rg1 and total saponin were also increased with the increase in drying temperature from 8$0^{\circ}C$ to 10$0^{\circ}C$, however, those were not significantly different with drying temperature at 100 and 12$0^{\circ}C$. Drying temperature for extrusion process can be optimal at 10$0^{\circ}C$.

A Survey on the Sanitary Management in Food Service Institutions (집단급식소의 위생관리에 대한 실태 조사)

  • Soh, Gowan-Soon;Kim, Yong-Suk;Shin, Dong-Hwa
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.1
    • /
    • pp.63-75
    • /
    • 2007
  • A survey on sanitary management at 98 food service institutions located in Jeollabuk-Do were conducted. Food service institutions included 13 hospitals, 38 schools, 40 enterprises, and 7 others. The sterilization in boiling water was used for disinfection of tableware, spoon and chopsticks, and dish towel. Cooking kit, refrigerator, chopping board, and knife were sterilized with disinfectant. Frequency of sanitary training program on employees was 56.1% for 1 time/month, 12.2% for 2-3 times/month, and 11.3% for 1 time/week. Preparing ratio of defrosting, warehouse and rest room, and washing and sterilization diary were 73.8, 60.5, and 54.5%, respectively. However, checking ratio of environments (9.5%), personal sanitation (10.8%), and sanitary training program diary(8.4%) were low. Major obstacle factors on the introduction of Hazard analysis critical control point (HACCP) system into food service institutions were lack of equipment and facilities (54.1%) and lack of understanding and data on HACCP system (17.3%). Therefore, in order to reduce the outbreak of food-borne diseases increasing frequency, we estimated that the introduction of sanitary management system and the conversion of dietician' perception on sanitary managements in food service institutions were needed.