• 제목/요약/키워드: central electrode

검색결과 106건 처리시간 0.027초

유한요소법에 의한 적층형 세라믹 히터의 전극 패턴 최적화 (Optimization of Electrode Pattern for Multilayer Ceramic Heater by Finite Element Method)

  • 한윤수;김시연;여동훈
    • 한국전기전자재료학회논문지
    • /
    • 제30권12호
    • /
    • pp.776-781
    • /
    • 2017
  • In this study, we investigated the effect of electrode pattern design on the thermal shock resistance and temperature uniformity of a ceramic heater. A cordierite substrate with a low thermal expansion coefficient was fabricated by tape casting, and a tungsten electrode was printed and used as a heating element. The temperature distribution of the ceramic heater was calculated by a finite-element method (FEM) by considering various electrode patterns, and the tensile stress distribution due to the thermal stress was calculated. In the electrode pattern with a single-line width, the central part of the ceramic heater was heated to the maximum temperature, and the position of the ceramic heater having a double-line width was changed to the maximum temperature, depending on the position of the minimum line width pattern. The highest tensile stress was found along the edges of the ceramic heater. The temperature gradient at the edge determined the tensile stress intensity. The smallest tensile stress was observed for electrode pattern D, which was expected to be advantageous in resisting thermal shock failures in ceramic heaters.

가공 전극을 적용한 590 MPa급 DP강의 저항 점용접에 관한 연구 (A Study on the Resistance Spot Weldability of 590 MPa Grade DP Steel with Modified Electrode Tip)

  • 이상민;박영도
    • 대한금속재료학회지
    • /
    • 제48권1호
    • /
    • pp.71-76
    • /
    • 2010
  • The use of advanced high-strength steels (AHSS) in automotive applications has steadily increased over the past few years. Two different failure modes are generally observed in shear-tension tests for resistance spot welds of AHSS. interfacial fractures and full button pullout. Despite high load-carrying capacity. the resistance spot welds in AHSS cue prone to interfacial fractures. To improve the load carrying ability of welds during shear-lap and cross tension tests. the tip surface of the electrode was grooved in a round shape. The electrode tip surface was modified so as to concentrate the current now in the central and circumferential portion of the electrode force. The results showed that the interfacial fracture was suppressed in welds using the modified electrode. In a comparison of failure mode during mechanical tests. the welds made with the modified electrode showed a higher tendency to fail via full button pullout fracture.

회전각 검출용 3축 수직 Hall 센서 (Three Branches Vertical Hall Sensor for Rotation Angle Detection)

  • 이지연;남태철
    • 한국전기전자재료학회논문지
    • /
    • 제18권9호
    • /
    • pp.840-845
    • /
    • 2005
  • A three branches vortical Hall sensor for detecting rotation angle of brushless motor has fabricated. The sensor is constructed three branches of $150{\mu}m$ width and $300{\mu}m$ distance from central electrode to Hall electrode. Each branch has one Hall output and one Hall input. The central electrode acts as common driving input. According to rotation angle change of brushless motor, sensor gives three position signals phase shifted by $120^{\circ}$. The sensitivity of sensor is 200V/A$\cdot$T at magnetic field of 0.1 T and constant driving current of 1mA. It has also showed three sine waves of Hall output voltages with $120^{\circ}$ phase over one motor rotation. The noise can limit sensor's resolution. We have measured sensor's noise characteristics. The detectable minimum magnetic field is $20{\mu}T$ at driving current 1mA, measured frequency 1 kHz and bandwidth$({\Delta}f)$ of 1Hz.

3상의 자계 검출을 위한 수직 Hall 센서의 제작 (Fabrication of vertical Hall sensor for detecting three phases magnetic field)

  • 이지연;남태철
    • 센서학회지
    • /
    • 제14권2호
    • /
    • pp.85-90
    • /
    • 2005
  • In this study, we have fabricated a three branches vertical Hall sensor for detecting three phases rotation informations of miniaturized brushless motor. The sensor gives three position signals phase shifted by $120^{\circ}$, corresponding to the motor driving signals. The branch has one Hall output and one input each other. The central part acts as common driving input. Sensor has branch width of $150{\mu}m$ and distance from central electrode to Hall electrode of $100{\mu}m$. The sensitivity of sensor is 250 V/$A{\cdot}T$ at magnetic field of 0.1 T. It has also showed three sine waves of Hall voltages with $120^{\circ}$ phase over a $360^{\circ}$ rotation. A packaged sensing part are $2{\times}2mm^{2}$ and has been successfully tested on a motor rotation at a speed up to 60,000 rpm.

Charging and Discharging Characteristics of Electric Double Layer Capacitors used for a Storage Battery of Solar Energy

  • Sung, Youl-Moon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권2호
    • /
    • pp.97-102
    • /
    • 2007
  • The charging/discharging characteristics of electric double layer capacitors (EDLCs) for an electric power storage device application were investigated. The specific area of the carbonaceous electrode surface by the BET method was in the range of $1800{\sim}2000\;m^2/g$. The charge distributions during charging and discharging were measured by means of a pulsed-electro-acoustic (PEA) method, and the voltage characteristics of EDLCs connected to solar cells were evaluated. The results showed that the distributions of positive and negative charges were spatially uneven, which was due to the mobility of the positive and negative charges in the carbonaceous electrode surface of the EDLCs. The charge accumulation region concentrated on central part of the carbonaceous electrode and the required times for charging and discharging were almost same.

Room Temperature Hydrogen Sensor

  • Cho, Hyoung Jin;Zhang, Peng;Seal, Sudipta
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.51.3-51.3
    • /
    • 2010
  • Due to the recent public awareness of global warming and sustainable economic growth, there has been a growing interest in alternative clean energy sources. Hydrogen is considered as a clean fuel for the next generation. One of the technical challenges related to the use of hydrogen is safe monitoring of the hydrogen leak during separation, purification and transportation. For detecting various gases, chemiresistor-type gas sensors have been widely studied and used due to their well-established detection scheme and low cost. However, it is known that many of them have the limited sensitivity and slow response time, when used at low temperature conditions. In our work, a sensor based on Schottky barriers at the electrode/sensing material interface showed promising results that can be utilized for developing fast and highly sensitive gas sensors. Our hydrogen sensor was designed and fabricated based on indium oxide (In2O3)-doped tin oxide (SnO2) semiconductor nanoparticles with platinum (Pt) nanoclusters in combination with interdigitated electrodes. The sensor showed the sensitivity as high as $10^7%$ (Rair/Rgas) and the detection limit as low as 30 ppm. The sensor characteristics could be obtained via optimized materials synthesis route and sensor electrode design. Not only the contribution of electrical resistance from the film itself but also the interfacial effect was identified as an important factor that contribute significantly to the overall sensor characteristics. This promises the applicability of the developed sensor for monitoring hydrogen leak at room temperature.

  • PDF

나선형 내부전극을 사용한 2중 원통형 오존발생기의 온도의존특성 (Temperature Dependence Characteristics of Double Cylindrical Type Ozonizer Using Spiral Type Internal Electrode)

  • 전병준;이상근;;이동헌;박원주;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2004-2006
    • /
    • 1999
  • In this paper, double Cylindrical type ozonizer has been designed and manufactured to improve ozone yield by cooling external electrode. The ozonizer equipped with three electrodes ( central, internal and external electrodes ). Discharge and ozone characteristics are described in this paper by varying the flow rate( Q ) of oxygen supplied gas, temperature of cooling gas and supplied voltage.

  • PDF

Does a Frontal 2-Electrode Electroencephalogram Provide Sufficient Neuropsychological Information in Various Major Psychiatric Disorders?

  • Sol Han;Hyen-Ho Hwang;Kang-Min Choi;Sungkean Kim;Seung-Hwan Lee
    • 대한불안의학회지
    • /
    • 제20권1호
    • /
    • pp.8-16
    • /
    • 2024
  • Objective : The purpose of this study is to compare the signal obtained from the frontal 2-electrodes EEG with that obtained from the temporal, central, and parietal 2 electrodes. Methods : EEGs were recorded in a total of 67 patients with major depressive disorder (MDD), 104 patients with schizophrenia (SCZ), and 29 patients with Alzheimer's disease (AD). For each disease group, there were healthy controls (HC) that were paired accordingly (HC1=69, HC2=104, HC3=27). The following measurements were compared across electrodes: band power, alpha peak frequency (APF), APF power, alpha asymmetry (AA), and Kolmogorov complexity (KC). Results : Statistically significant differences were found in band power measured from frontal electrodes compared to electrodes placed in other locations. Specifically, the power of theta waves was measured higher in the temporal electorodes, alpha 1 and alpha 2 waves in the parietal, beta 1 and beta 2 in the central, and gamma waves in the temporal electrodes. Both SCZ and AD patients showed increased theta power in all electrodes. In SCZ patients, APF decreased in the central and temporal electrodes, but the APF power analysis showed no difference between the patients and controls. Additionally, AD patients exhibited increased AA in the central EEG, while SCZ patients showed decreased KC in the parietal and temporal electrodes. Conclusion : Depending on the electrode location, sensitive EEG frequencies differed. Compared with signals from other electrodes, frontal EEG in MDD patients revealed generally constant signal values, though the temporo-parieto-central electrodes appeared to be more reliable in SCZ and AD patients.

해수용 기준전극 개발을 위한 겔 타입 내부전해질 제조 및 잔류염소 측정장치에의 적용 (Fabrication of Gel-type Electrolyte for the Development of Reference Electrode for Sea Water and Application to Measuring Equipment for Total Residual Oxidants)

  • 김유진;이해돈;김대원
    • 공업화학
    • /
    • 제28권2호
    • /
    • pp.153-157
    • /
    • 2017
  • Hydroxyethyl-cellulose (HEC) 함량별로 겔 타입 내부전해질을 제작하여 이온전도도와 내구성 측정 실험을 수행하였다. 이온전도도 측정결과 HEC 함량이 증가할수록 이온전도도가 감소하여 12% 함량의 겔 타입 내부전해질은 기준전극에 적용이 어려울 것으로 판단하였다. HEC 함량별 내구성 실험결과, HEC의 함량이 감소할수록 carrier density가 증가하여 다공성 막을 통해 유출되는 전해질(KCl)의 양이 증가하였다. 따라서 선박평형수 처리장치와 같이 장시간 사용하기 위해 겔 타입 내부전해질을 HEC 10%로 선정하였다. HEC 10%의 겔 타입 내부전해질을 이용하여 기준전극과 TRO (total residual oxidants) 센서를 제작하여 TRO 분리능 실험을 수행하였다. TRO 센서에 50 mV의 전위를 30 s 동안 동일하게 인가하여 전류변화를 비교한 결과 0.2~30 PSU 조건에서 0~15 mg/L의 TRO 농도가 분리됨을 확인하였다. 따라서 HEC를 이용한 겔 타입 내부전해질을 TRO 센서에 적용할 수 있으며, 이를 이용하여 담수뿐만 아니라 해수 조건에서 TRO를 측정할 수 있음을 확인하였다.

Electrochemical Determination of 6-Benzylaminopurine (6-BAP) Using a Single-wall Carbon Nanotube-dicetyl Phosphate Film Coated Glassy Carbon Electrode

  • Li, Chunya
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권7호
    • /
    • pp.991-994
    • /
    • 2006
  • Herein, insoluble single-walled carbon nanotube (SWNT) was successfully dispersed into water in the presence of a special kind of surfactant-dicetyl phosphate (DCP), subsequently, a SWNT-DCP composite film coated glassy carbon electrode (GCE) was fabricated. The electrochemical behaviors of 6-benzylaminopurine (6-BAP) at the unmodified GCE and SWNT-DCP modified GCE were examined. It is found that the SWNT-DCP modified GCE remarkably enhances the oxidation peak current of 6-BAP, indicating great potential in the determination of trace level of 6-BAP. Finally, a sensitive and simple voltammetric method with a good linear relationship in the range of ${\times}5.0\;\;10^{-8}\sim 2.5\;{\times}\;10^{-6}$ mol/L, was developed for the determination of 6-BAP. The detection limit is as low as $2.0\;{\times}\;10^{-8}$ mol/L for 3-min accumulation. This newly-proposed method was successfully demonstrated with practical samples.