• 제목/요약/키워드: cable jacket

검색결과 31건 처리시간 0.023초

Development of Waterproof Jacket Materials for Power Cables

  • Han, Yong-Huei;Jung, Jong-Wook;Kwon, Tae-Ho;Song, Hyun-Seok;Koo, Kyo-Sun;Han, Byung-Sung
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.146-154
    • /
    • 2003
  • This paper describes various characteristics of the new compounds for cable jackets and model cables advanced in waterproof performance in order to essentially solve the problems of underground (URD) distribution class power cable failures. Several compounds were manufactured by the inclusion of additives to base resins available in Korea and tested for basic property, mechanical and electrical characteristics. Two model cables were created by using the compounds determined in the test as being the most appropriate for new structured model cable jacket material. The waterproof performance and mechanical strength of the new cable jackets were verified by applicable tests. As a result, MDPE and LLDPE compounds were superior as cable jackets in both mechanical and electrical characteristic aspects when compared with conventional PVC. In addition, the model cables composed of the new compounds based on MDPE showed good quality results in the water permeability test.

Evaluation of Nuclear Plant Cable Aging Through Condition Monitoring

  • Kim, Jong-Seog;Lee, Dong-Ju
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.475-484
    • /
    • 2004
  • Extending the lifetime of a nuclear power plant [(hereafter referred to simply as NPP)] is one of the most important concerns in the global nuclear industry. Cables are one of the long-life items that have not been considered for replacement during the design life of a NPP. To extend the cable life beyond the design life, it is first necessary to prove that the design life is too conservative compared with actual aging. Condition monitoring is useful means of evaluating the aging condition of cable. In order to simulate natural aging in a nuclear power plant. a study on accelerated aging must first be conducted. In this paper, evaluations of mechanical aging degradation for a neoprene cable jacket were performed after accelerated aging under tcontinuous and intermittent heating conditions. Contrary to general expectations, intermittent heating to the neoprene cable jacket showed low aging degradation, 50% break-elongation, and 60% indenter modulus, compared with continuous heating. With a plant maintenance period of 1 month after every 12 or 18 months operation, we can easily deduce that the life time of the cable jacket of neoprene can be extended much longer than extimated through the general EQ test. which adopts continuous accelerated aging for determining cable life. Therefore, a systematic approach that considers the actual environment conditions of the nuclear power plant is required for determining cable life.

원자력 발전소용 통신케이블 자켓의 가속열화시험 (An Accelerated Degradation Test of Nuclear Power Plants Communication Cable Jacket)

  • 정재한;김용수
    • 품질경영학회지
    • /
    • 제45권4호
    • /
    • pp.969-980
    • /
    • 2017
  • Purpose: The purpose of this study was to estimate the lifetime, and verify the target lifetime at steady state temperature, of communication cable jackets used in nuclear power plants. Method: This study was completed according to test and analysis methods required by international standards. After measuring the residual elongation(%) of specimens at specific points in time with the accelerated degradation test, average failure time of each temperature was computed. Thus, the activation energy could be derived by applying the temperature-Arrhenius law to estimate cable jacket lifetime at steady state temperature. Results: The cable jacket lifetime was estimated as 363.8 years assuming a normal nuclear power plant operating temperature of $90^{\circ}C$. Conclusion: To ascertain stable operating conditions for a nuclear power plant, accelerated degradation tests were performed according to the Arrhenius law for components of the nuclear power plants. The lifetime was estimated from the degradation data collected during the accelerated degradation test.

Computational Fluid Dynamics를 활용한 점/접착 생산 공정 내 Jacketed Vessel 설계 최적화 (Optimization of Plain Jacked Vessel Design in Adhesive Production Process Using Computational Fluid Dynamics)

  • 주종효;박현도;조형태;김정환
    • 공업화학
    • /
    • 제31권6호
    • /
    • pp.596-602
    • /
    • 2020
  • 점/접착제 생산 공정은 배합 과정에서 mineral insulated (MI) cable을 통해 내부 용액을 76 ℃까지 가열 및 혼합 후 제품 출하를 위해 30 ℃까지 상온 냉각을 진행한다. MI cable을 이용한 반응기의 경우, 냉각시간이 평균 10 h 소요되어 생산효율이 낮은 문제점이 있지만, jacketed vessel을 설치하면 위의 문제를 효과적으로 해결할 수 있다. 그러나 jacketed vessel의 종류가 다양해 jacket을 설치하기 전, 배합 공정조건에 적합한 종류를 찾아야 한다. 본 연구에서는 생산효율에 영향을 주는 냉각시간을 최소화하기 위해 computational fluid dynamics (CFD)를 이용하여 jacket 종류에 따른 냉각시간을 비교해 공정에 적합한 jacketed vessel 모델을 개발하고, 점/접착제 생산 공정에 최적화된 jacketed vessel을 설계하였다. 연구 결과, jacket의 높이가 같을 때, half-pipe coil jacket보다 plain jacket의 냉각 성능이 32.7% 더 우수하였고, plain jacket에 60% spiral baffle을 설치하여 냉각 공정에 이용할 경우 냉각시간을 80.4%, 작업시간을 25.1% 단축 가능하다.

지중송전케이블의 불완전 순환전류에 관한 연구 (A Study on unperfected circuiting current of undergrounded cable)

  • 이관우;이용성;김보경;박복기;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.3-6
    • /
    • 2004
  • In this paper, we studied on permissible current of unperfected earthing for cross-bond system. The factors of unperfected earth were jacket damage, cross-bonding mistake, arrestor damage, effect of other circuit but we only studied permissible current of arrestor or jacket damage. In the result, we earned that permissible current of normal 154[[kV]] CV $1C{\times}400SQMM$ cable is 760[A] but current of unperfected earthing cable is 76[A], unperfected earthing confirmed that accident of underground cable could occur. So, we could confirmed that Earthing resistance of unperfected earthing need to limit.

  • PDF

이질 누화 특성이 개선된 UTP LAN 케이블의 설계 (Design of UTP LAN Cable With Enhanced Alien Crosstalk Characteristic)

  • 김준형;이성준;오승기
    • 한국통신학회논문지
    • /
    • 제37A권12호
    • /
    • pp.1115-1121
    • /
    • 2012
  • 본 논문에서는 이질 누화 특성이 개선된 UTP(Unshielded Twisted Pair) LAN(Local Area Network) 케이블의 설계를 제안하였다. 제안된 LAN 케이블은 불규칙적인 돌비 형태의 구조를 갖는 피복과 필요시 특수 제작된 크로스필러가 사용될 수 있게 설계되었다. 피복 내부면에 존재하는 서로 다른 높이와 폭을 갖는 돌비는 특정한 주파수 대역이 아닌 넓은 주파수 대역에 걸쳐 차폐부를 구현시킴으로서 외부의 다른 LAN 케이블에 끼치는 간섭을 줄일 수 있는 구조이다. 본 논문의 구조를 이용함으로서 케이블 피복에 구현되어진 차폐부로 인하여 이질 누화 특성을 향상시킬 수 있다. 또한 제안된 구조는 국제 규격인 ANSI/TIA/EIA-568-B.2-10 등을 만족시킨다.

저임피던스 케이블의 허용전류에 대한 연구 (A Study on Permissible Current of Low Impedance Cable)

  • 김동식;박복기;이종찬;이관우;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.513-515
    • /
    • 1999
  • In this study, we evaluated the relation of the test and theory of low impedance cable As the result We could obtained the result in accordance the test with theory in 85 ~ 95% tolerance . Test method measured the relation of the current and temperature of cable jacket in using CT to put in 3 phase AC current simultationiously. The current and temperature of it was calculated in according to JCS- l68D

  • PDF

Stick Type Ignition Coil Jacket PET의 접촉응력 해석 (Contact Stress Analysis of Stick Type Ignition Coil Jacket PET)

  • 김양술
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2005
  • Stick type ignition coil is new development that connect directly with ECU(Electronic control unit), without needing a spark plug cable and distributor. Glass-fiber reinforced ploymeric composites provide the desirable properties of high stiffness and strength as well as low specific weight. Stick type ignition coil jacket is using PBT CF30 resin. PBT CF30 resin is a kind of electric insulation which is a superior engineering plastic that is used to prevent the leakage of the electrical current. If PET receive a mistake of design or excessive force when HV terminal oppress on jacket, it can happen to crack. Local stress concentrations occurring on the contact surface, the contact phenomenon becomes a direct cause to the wear and failure of mechanical structures. When it is cracked, it can allow a leakage of the electrical current. So, in this study, we analyze the contact stress to PBT jacket using ANSYS program, when HV terminal oppress on jacket. We suppose PBT to be Jacket and we analyzed contact stress that happens in PET like PBT analysis method. We compared the use of PBT and PET.

Foundation Types of Fixed Offshore Wind Turbine

  • Yun Jae Kim;Jin-wook Choe;Jinseok Lim;Sung Woong Choi
    • 한국해양공학회지
    • /
    • 제38권2호
    • /
    • pp.74-85
    • /
    • 2024
  • Offshore wind turbines are supported by various foundations, each with its considerations in design and construction. Gravity, monopile, and suction bucket foundations encounter geotechnical issues, while jacket and tripod foundations face fatigue problems. Considering this, a gravity foundation based on a steel skirt was developed, and a monopile foundation was analyzed for Pile-Soil Interaction using the p-y curve and 3D finite element method (3D FEM). In addition, for suction bucket foundations, the effects of lateral and vertical loads were analyzed using 3D FEM and centrifuge tests. Fatigue analysis for jacket and tripod foundations was conducted using a hotspot stress approach. Some hybrid foundations and shape optimization techniques that change the shape to complement the problems of each foundation described above were assessed. Hybrid foundations could increase lateral resistance compared to existing foundations because of the combined appendages, and optimization techniques could reduce costs by maximizing the efficiency of the structure or by reducing costs and weight. This paper presents the characteristics and research directions of the foundation through various studies on the foundation. In addition, the optimal design method is presented by explaining the problems of the foundation and suggesting ways to supplement them.

초고압 XLPE 케이블의 국부적 늘림에 대한 파괴강도 고찰 (Evaluation of Breakdown Strength on the Locally Dented Power Cable)

  • 김영호;이상진;조대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.251-254
    • /
    • 2001
  • Internal and external forces may be applied on the power cable in the both process of transportation and installation. Even though the EHV power cables have the structure of metal sheath and plastic jacket etc. to minimize these negative influences, the unusual forces result in the unexpected deformation of the cable. Compressing moulded XLPE model cable sheets were prepared and locally dented with round-edge and square-edge tools. All data were analyzed employing Weibull distribution. The breakdown strength of dented molded specimens showed lower values than the normal ones by 10-60%.

  • PDF