DOI QR코드

DOI QR Code

An Accelerated Degradation Test of Nuclear Power Plants Communication Cable Jacket

원자력 발전소용 통신케이블 자켓의 가속열화시험

  • Jung, Jae Han (Department of Industrial and Management Engineering, Kyonggi University Graduate School) ;
  • Kim, Yong Soo (Department of Industrial and Management Engineering, Kyonggi University)
  • 정재한 (경기대학교 일반대학원 산업경영공학과) ;
  • 김용수 (경기대학교 산업경영공학과)
  • Received : 2017.09.10
  • Accepted : 2017.11.08
  • Published : 2017.12.31

Abstract

Purpose: The purpose of this study was to estimate the lifetime, and verify the target lifetime at steady state temperature, of communication cable jackets used in nuclear power plants. Method: This study was completed according to test and analysis methods required by international standards. After measuring the residual elongation(%) of specimens at specific points in time with the accelerated degradation test, average failure time of each temperature was computed. Thus, the activation energy could be derived by applying the temperature-Arrhenius law to estimate cable jacket lifetime at steady state temperature. Results: The cable jacket lifetime was estimated as 363.8 years assuming a normal nuclear power plant operating temperature of $90^{\circ}C$. Conclusion: To ascertain stable operating conditions for a nuclear power plant, accelerated degradation tests were performed according to the Arrhenius law for components of the nuclear power plants. The lifetime was estimated from the degradation data collected during the accelerated degradation test.

Keywords

References

  1. ANSI/IEEE Std 1-1986. 1986. IEEE Standard General Principles for Temperature Limits in the Rating of Electrical Equipment and for the Evaluation of Electrical Insulation : IEEE STANDARDS ASSOCIATION.
  2. Chun, Y. H., and Kwon, L. J. 1997. "Accelerated Life Test and Data Analysis of the Silver Through Hole Printed Wiring Board." J Korean Soc Qual Manag 25(2):15-27.
  3. Jung, J. H., Kim, M. S., Lim, H., and Kim, Y. S. 2013. "A Study on Accelerated Life of Halogen Lamps for Medical Device." J Korean Soc Qual Manag 41(4):659-672. https://doi.org/10.7469/JKSQM.2013.41.4.659
  4. Kim, S. B., and Kim, S. H. 2015. "Estimation of Elevator Wire Life Using Accelerated Degradation Model." J Korean Soc Qual Manag 43(1):409-420. https://doi.org/10.7469/JKSQM.2015.43.3.409
  5. Lim, H., and Lim, D-E. 2015. "Planning Accelerated Degradation Tests: the Case of Gamma Degradation Process." J Korean Soc Qual Manag 43(2):169-184. https://doi.org/10.7469/JKSQM.2015.43.2.169
  6. Lim, H. 2012. "Optimal Design of Accelerated Degradation Tests under the Constraint of Total Experimental Cost in the Case that the Degradation Characteristic Follows a Wiener Process." J Korean Soc Qual Manag 40(2):117-125. https://doi.org/10.7469/JKSQM.2012.40.2.117
  7. Kim, J-H., Kim, D-H., Hwang, J-K., and Kim, S. 2011. "Research on the Resources Investigations of Small Hydropower Generation in Northern Gyeong-Buk Area." Journal of Korea Water Resources Association 31(5):459-456.
  8. Han, S. W., Kwak, S. B., and Choi, N. S. 2014. "Accelerated Life Prediction of Ethylene-Propylene Diene Monomer Rubber Subjected to Combined Degradation." Trans. Korean Soc. Mech. Eng. 38(5):505-511. https://doi.org/10.3795/KSME-A.2014.38.5.505
  9. ANSI/IEEE Std 98-1984. 1984. IEEE Standard for the Preparation of Test Procedures for the Thermal Evaluation of Solid Electrical Insulting Materials : IEEE STANDARDS ASSOCIATION.
  10. ANSI/IEEE Std 99-1980. 1980. IEEE Recommended Practice for the Preparation of Test Procedures for the Thermal Evaluation for Insulation Systems for Electrical Equipment : IEEE STANDARDS ASSOCIATION.
  11. ANSI/IEEE Std 275-1981. 1981. IEEE Recommended Practice for Thermal Evaluation of Systems of Insulating Materials for Random-Wound AC Electric Machinery : IEEE STANDARDS ASSOCIATION.
  12. Regulatory Guide 1.89 Rev. 1. 1984. Environmental Qualification of Criteria Electric Equipment Important to Safety for Nuclear Power Plants. U.S. Nuclear Regulatory Commission : OFFICE OF NUCLEAR REGULATORY RESEARCH.