• Title/Summary/Keyword: bundle

Search Result 1,448, Processing Time 0.036 seconds

Eigen 1-forms of the laplacian and riemannian submersions

  • Park, Jeong-Hyeong
    • Bulletin of the Korean Mathematical Society
    • /
    • v.33 no.3
    • /
    • pp.477-480
    • /
    • 1996
  • Let $\pi : Z \longrightarrow Y$ be a fiber bundle where Y and Z are compact Riemannian manifolds without boundary. We are primarily interested in the case where $\pi$ is a Riemannian submersion with minimal fibers; this is the case, for example, where Z is the sphere bundle of some vector bundle over Y or where Z is a principal bundle over Y.

  • PDF

RIGIDITY OF MINIMAL SUBMANIFOLDS WITH FLAT NORMAL BUNDLE

  • Seo, Keom-Kyo
    • Communications of the Korean Mathematical Society
    • /
    • v.23 no.3
    • /
    • pp.421-426
    • /
    • 2008
  • Let $M^n$ be a complete immersed super stable minimal submanifold in $\mathbb{R}^{n+p}$ with fiat normal bundle. We prove that if M has finite total $L^2$ norm of its second fundamental form, then M is an affine n-plane. We also prove that any complete immersed super stable minimal submanifold with flat normal bundle has only one end.

A NEW CLASS OF RIEMANNIAN METRICS ON TANGENT BUNDLE OF A RIEMANNIAN MANIFOLD

  • Baghban, Amir;Sababe, Saeed Hashemi
    • Communications of the Korean Mathematical Society
    • /
    • v.35 no.4
    • /
    • pp.1255-1267
    • /
    • 2020
  • The class of isotropic almost complex structures, J𝛿,𝜎, define a class of Riemannian metrics, g𝛿,𝜎, on the tangent bundle of a Riemannian manifold which are a generalization of the Sasaki metric. This paper characterizes the metrics g𝛿,0 using the geometry of tangent bundle. As a by-product, some integrability results will be reported for J𝛿,𝜎.

Design and Implementation of HNCP Bundle in the OSGi Framework (OSGi 프레임워크 환경에서의 HNCP 번들 설계 및 구현)

  • 허종만;이재민;명관주;권욱현
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.51-54
    • /
    • 2003
  • This paper describes the design and implementation of HNCP bundle in the OSGi framework targeted to the home network system. The developed home network system is composed of a home server and several networked home appliances, and is connected via residential gateway to the external access network. The developed HNCP bundle allows a user to control and monitor home appliances in HNCP domain. We show the feasibility of the implemented HNCP bundle in the OSGi framework.

  • PDF

CLASSIFICATION OF THE EQUIVARIANT LINE BUNDLES OVER $S^1$ (원 위에서의 EQUIVARIANT LINE BUNDLE 의 분류)

  • Kim, Seong-Suk
    • The Journal of Natural Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-3
    • /
    • 1992
  • G가 compact Lie 군이고 $\pi$ : $E to S^1$$S^1$ 상의 G-line bundle 일때, 군 작용이 없다면, 부드러운 trivial G-line bundle $E to S^1$ 은 S(V) $\times$ $\delta to S(V)$ 와 동치이고 부드러운 nontrivial G-line bundle $E to S^1$ 은 S(V) $\times$$z_2$ $\delta to S(V)$/$Z_2$=P(V)와 동치 이다.

  • PDF

COMPLETE LIFTS OF PROJECTABLE LINEAR CONNECTION TO SEMI-TANGENT BUNDLE

  • Polat, Murat;Yildirim, Furkan
    • Honam Mathematical Journal
    • /
    • v.43 no.3
    • /
    • pp.483-501
    • /
    • 2021
  • We study the complete lifts of projectable linear connection for semi-tangent bundle. The aim of this study is to establish relations between these and complete lift already known. In addition, the relations between infinitesimal linear transformations and projectable linear connections are studied. We also have a new example for good square in this work.

Notes on the Second Tangent Bundle over an Anti-biparaKaehlerian Manifold

  • Nour Elhouda Djaa;Aydin Gezer
    • Kyungpook Mathematical Journal
    • /
    • v.63 no.1
    • /
    • pp.79-95
    • /
    • 2023
  • In this note, we define a Berger type deformed Sasaki metric as a natural metric on the second tangent bundle of a manifold by means of a biparacomplex structure. First, we obtain the Levi-Civita connection of this metric. Secondly, we get the curvature tensor, sectional curvature, and scalar curvature. Afterwards, we obtain some formulas characterizing the geodesics with respect to the metric on the second tangent bundle. Finally, we present the harmonicity conditions for some maps.

Arthroscopic Double-Bundle Reconstruction of Anterior Cruciate Ligament (관절경을 이용한 전방 십자 인대의 이중 다발 재건술)

  • Jung, Young-Bok;Park, Se-Jin;Jung, Ho-Joong;Yoo, Jae-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.11 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Purposes: The purpose of this study was to report surgical technique of double bundle anterior cruciate ligament(ACL) reconstruction and to compare the short-term clinical results between arthroscopic single-bundle and double-bundle ACL reconstruction. Materials and Methods: From May 2005 to May 2006, ninety-eight patients were underwent ACL reconstruction. We designed prospective study with sixty-one patients who were revealed isolated ACL injury. We serially checked clinical and radiologic data preoperatively and postoperatively. We compared single-bundle with double-bundle ACL reconstruction patients with preoperative datas and postoperatively 1-year data. There were 30 single bundle reconstruction and 31 double bundle reconstruction. Stability was assessed objectively by anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer. The clinical results were assessed by IKDC(International Knee Documentation Committee) and OAK(Orthopadische Arbeitsgruppe Knie) scores. Also, we evaluated postoperative thigh circumference and range of motion. All of operations were done by only one surgeon. Results: At single-bundle reconstruction group, preoperative AP instability which was checked by $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer was $7.9{\pm}3.3$ and $7.4{\pm}2.0$, respectively. At double-bundle reconstruction group, it was $8.3{\pm}3.5$ and $7.9{\pm}3.2$, respectively. Residual AP laxity checked at 1 year after operation was $1.9{\pm}1.2$ and $2.2{\pm}1.6$ in single-bundle reconstruction group, and $1.1{\pm}0.9$ and $1.0{\pm}1.0$ in double-bundle reconstruction group. So, double-bundle reconstruction had better results in both anterior stress radiographs with the $Telos^{(R)}$ device and the maximal manual test with the KT-2000 arthrometer, and there were significant differences in statistics. But, clinical results such as IKDC(International Knee Documentation Committee) scores, OAK(Orthopadische Arbeitsgruppe Knie) scores, thigh circumference and range of motion had no significant difference between two groups. Conclusions: On the basis of stability, the side-to-side anterior laxity of double-bundle ACL reconstruction was significantly better than that of single-bundle reconstruction, although there were no significant differences in the other clinical measures among them.

  • PDF

Negative Corona Onset Characteristic of the UHV Conductors Based on the Corona Cage

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Xie, Xiongjie
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2089-2097
    • /
    • 2014
  • Negative corona onset characteristics of the stranded conductors based on the ultra-high voltage (UHV) corona cage were studied in the paper. Based on the corona self-sustaining criterion in extreme uneven electric fields and the secondary emission process of the photoelectrons, the corona onset calculation model in the UHV corona cage is established and the corona current tests of the single LGJ900-75, 6 bundle LGJ900-75, 8 bundle LGJ400-35 conductors in dry and rain conditions were done in the UHV corona cage, and the rain rates are 2.4 mm/h, 20 mm/h and 30 mm/h. Corona onset electric field strength is gained by E-I tangent method, and the onset electric field strength in dry condition proves that the calculation model can be used to calculate the corona onset characteristics of the bundle conductors in the UHV corona cage. A further analysis proves that: the negative corona onset voltage of the conductor increases with the bundle number and the diameter of the sub conductor, but decreases with the bundle space in the corona cage. The onset electric field strength is influenced little by bundle space and bundle number, but decreases with the increase of the diameter of the sub-conductor. The surface irregularity coefficient decreases with the rain rate.

Impact of Central Line Insertion Bundle on the Adherence of Bundle and Central Line-Associated Bloodstream Infections in the Operating Room (수술실에서 중심정맥관 삽입 시 번들적용이 중심정맥관 관련 혈류감염에 미치는 영향)

  • Shin, Eun Jeong;Jeong, Jae Sim;Choi, Sang Ho;Huh, In Young
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.4
    • /
    • pp.257-263
    • /
    • 2016
  • Background: This study purposed to examine how the incidence of the central line-associated bloodstream infection (CLABSI) in a operating room (OR) is affected by bundle application on central line insertion (CLI) practice. Methods: The study design was a pretest-posttest experimental trial. The subjects were 83 patients before the bundle application on CLI and 70 patients after. Results: The compliance(%) of bundle on CLI of among those who observed all of the five items increased from 7.2% before the intervention to 72.9% after. By items, compliance with the maximal barrier precaution was 100% for the use of a mask and cap before and after the intervention, but increased from 73.5% before the intervention to 88.6% after for the hand hygiene, from 73.5% to 88.6% for the use of a sterile gown, and from 9.6% to 75.7% for the use of a sterile large drape covering the whole body. CLABSI did not happen on CLI either before or after the application of the bundle intervention. Conclusion: Bundle application increased compliance with the use of a sterile gown and the use of a sterile large drape. However, its effect in the prevention of CLABSI was not clear probably due to the short period of intervention in a single hospital.