• 제목/요약/키워드: bio-signal detection

검색결과 90건 처리시간 0.031초

가상현실환경에서 멀미 측정을 위한 생리신호 분석 (Practical BioSignal analysis for Nausea detection in VR environment)

  • Park, M.J.;Kim, H.T.;Park, K.S.
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2002년도 추계학술대회 논문집
    • /
    • pp.267-268
    • /
    • 2002
  • We developed nausea, caused by disorder of autonomic nervous system, detection system using bio-signal analysis and artificial neural network in virtual reality enironment. We used 16 bio-signals, 9 EEGs, EOG, ECG, SKT, PPG, GSR, RSP, EGC, which has own analysis methods. We estimated nausea level by artificial neural network.

  • PDF

405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능 (The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode)

  • 정영수;정유진;이종민;최기봉
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

새로운 신호모델에 의한 CW 레이다 심장박동 및 호흡검출 성능분석 (Heart beat and Respiration Detection Performance of CW radar Based on New Signal Model)

  • 이병섭
    • 한국위성정보통신학회논문지
    • /
    • 제12권1호
    • /
    • pp.28-33
    • /
    • 2017
  • 본 논문에서는 여러 곳에서 통용되고 있는 기존의 CW(continuous-wave) 레이더 송수신모델을 수정한 송수신모델을 제안한다. 최근에 심장박동과 호흡을 검출하기 위해 기존신호모델을 기반으로 CW(continuous-wave) 레이더에 대한연구가 진행 되고 있다. 그러나 이 통용되고 있는 수신모델은 인체 공학적으로 개념과 일치하지 않기 때문에 이모델을 근거로 실험을 할 경우 실제 개발되는 시스템 성능을 정확하게 예측할수 없다. 본 논문에서는 인체 공학상 개념과 일치하는 수정된 CW(continuous-wave) 레이더 송수신모델을 제안하고 가운시안 잡음rhk 다중경로 환경에서 심장박동 및 호흡검출에 대한 시뮬레이션을 수행하고 이를 기존수신모델과의 심장박동과 호흡검출에 대한 성능을 비교 분석한다.

위전도신호의 측정 및 분석시스템 개발 (Development of Detection and Analysis System for Electrogastrographic Signal)

  • 한완택;김인영
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.261-268
    • /
    • 1998
  • 위전도는 피부전극을 이용하여 위에서 발생하는 전기신호를 측정하여 위운동상태를 측정하는 비관혈적인 검사방법이다. 본 연구에서는 임상적으로 유용한 위전도신호 측정 및 분석시스템을 개발하였으며, 개발시스템은 크게 하드웨어(생체증폭기, 필터)와 소프트웨어(유저인터페이스, 분석알고리듬, 환자데이터베이스)로 구성된다. 개발시스템의 생체신호증폭기는 신호분석에 용이하도록 3채널로 구성되어 있으며, 신호의 저장 및 분석은 PC에서 수행하도록 구성되어 있다. 위수축 정보의 획득을 위해서 분석신호는 16Hz로 샘플링하였으며, 위전도신호분석은 임상이용에 유용한 여러 가지 분석 파라메터를 추출할 수 있도록 하였다. 개발된 시스템은 동물실험을 통하여 성능을 평가하였으며, 현재 환자를 대상으로 임상시험이 진행중이다.

  • PDF

Multi-modal Authentication Using Score Fusion of ECG and Fingerprints

  • Kwon, Young-Bin;Kim, Jason
    • Journal of information and communication convergence engineering
    • /
    • 제18권2호
    • /
    • pp.132-146
    • /
    • 2020
  • Biometric technologies have become widely available in many different fields. However, biometric technologies using existing physical features such as fingerprints, facial features, irises, and veins must consider forgery and alterations targeting them through fraudulent physical characteristics such as fake fingerprints. Thus, a trend toward next-generation biometric technologies using behavioral biometrics of a living person, such as bio-signals and walking characteristics, has emerged. Accordingly, in this study, we developed a bio-signal authentication algorithm using electrocardiogram (ECG) signals, which are the most uniquely identifiable form of bio-signal available. When using ECG signals with our system, the personal identification and authentication accuracy are approximately 90% during a state of rest. When using fingerprints alone, the equal error rate (EER) is 0.243%; however, when fusing the scores of both the ECG signal and fingerprints, the EER decreases to 0.113% on average. In addition, as a function of detecting a presentation attack on a mobile phone, a method for rejecting a transaction when a fake fingerprint is applied was successfully implemented.

나노입자를 이용한 마이크로 바이오칩의 전기적 신호검출 (An Electrical Signal Detection System Using Nanoparticle for a Microbiochip)

  • 라광열;박재준;이성환;안유민;조남규;황승용
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.1-7
    • /
    • 2006
  • A system for the electrical bio signal detection for a microchip is proposed. Gold nanoparticles were selected for the system for their bio-compatibility and potential for higher sensitivity with large surface areas. For the estimation of the conductivity of gold nanoparticles, microchips with interdigitated microelectrodes of 3,5,7 and $9\;{\mu}m$ spacing were fabricated. In addition, a simulation program was developed to estimate the electrical resistance of the fabricated microchip. The results of conduction simulation for the nanoparticles show good agreements with experimental data, which validate the proposed system.

수산음향계측장치의 탐지범위에 대한 연구 (A Study on the Detection Range of Acoustic Instruments for Fisheries)

  • 박주삼
    • 수산해양기술연구
    • /
    • 제41권1호
    • /
    • pp.54-63
    • /
    • 2005
  • 어군탐지기, 계량어군탐지기, 바이오텔레메터리등 음향을 이용하여 해중의 어군의 정보를 탐색하는 수산음향계측장치의 탐지범위와 그 음향특성에 대해 검토, 분석할 결과를 요약하면 다음과 같다. 1. 탐지범위는 송 ${\codt}$ 수파기 직경, 송파음의 강도의 증가와 함께 저주파로 이동하여 어군탐지기의 경우 20${\sim}$50kHz, 바이오텔레메터리의 경우 40${\sim}$80kHz에서 최대치를 나타내었다. 2. 탐지거리는 주파수의 증가와 함께 증가하였지만, 고주파에서는 흡수계수의 영향으로 급격하게 감소하였다. 즉, 송 ${\codt}$ 수파기 직경, 송파음의 강도, TS의 증가 효과는 저주파에서는 크고 고주파에서는 적은 경향을 나타내었다. 3. 바이오텔레메터리에서는 어군탐지기와 같은 송파의 지향성 이득을 얻을 수 없기 때문에 탐지체적의 최대치가 수파기의 직경과 함께 미소하게 감소하였다. 4. 탐지범위는 주파수 특성에 의한 어군탐지기의 음향산란신호를 분석하건, 수산음향계측장치의 설계 및 성능평가에 유효하게 사용될 수 있다.

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

나노바이오기술을 이용한 환경모니터링용 바이오칩 시스템 (Biochip System for Environmental Monitoring using Nanobio Technology)

  • 김영기;민준홍;오병근;최정우
    • KSBB Journal
    • /
    • 제22권6호
    • /
    • pp.378-386
    • /
    • 2007
  • 바이오센싱 디바이스는 본질적으로 생체인식소재와 신호전달장치로 구성된 집적화, 소형화된 분석시스템으로 많은 장점을 가지고 있다. 고민감도, 선택도, 단순성, 다성분 측정능력, 즉시측정능력 뿐 아니라 매우 작고, 고가의 장치가 필요없는 장점이 있다. 바이오센싱 디바이스의 개발을 위해서는 두 가지의 핵심요소기술이 필요하다. 이것은 생체인식소재모듈의 제작 (리셉터 개발 및 고정화기법)과 신호발생기술을 포함한 신호전달장치의 개발이다. 효소, DNA/RNA, 단백질, 세포 등의 다양한 생체인식소재가 바이오센싱 디바이스 제작을 위해 이용되어져 왔고, 신호전달시스템도 전기화학적, 광학적, mass sensitive transducer를 중심으로 매우 활발히 연구되어져 왔다. 본 고에서는 최근 개발된 바이오센싱디바이스에 대해 다루고, 향후 전망에 대해 논하고자 한다.