• Title/Summary/Keyword: binocular data

Search Result 45, Processing Time 0.021 seconds

High Performance Coprocessor Architecture for Real-Time Dense Disparity Map (실시간 Dense Disparity Map 추출을 위한 고성능 가속기 구조 설계)

  • Kim, Cheong-Ghil;Srini, Vason P.;Kim, Shin-Dug
    • The KIPS Transactions:PartA
    • /
    • v.14A no.5
    • /
    • pp.301-308
    • /
    • 2007
  • This paper proposes high performance coprocessor architecture for real time dense disparity computation based on a phase-based binocular stereo matching technique called local weighted phase-correlation(LWPC). The algorithm combines the robustness of wavelet based phase difference methods and the basic control strategy of phase correlation methods, which consists of 4 stages. For parallel and efficient hardware implementation, the proposed architecture employs SIMD(Single Instruction Multiple Data Stream) architecture for each functional stage and all stages work on pipelined mode. Such that the newly devised pipelined linear array processor is optimized for the case of row-column image processing eliminating the need for transposed memory while preserving generality and high throughput. The proposed architecture is implemented with Xilinx HDL tool and the required hardware resources are calculated in terms of look up tables, flip flops, slices, and the amount of memory. The result shows the possibility that the proposed architecture can be integrated into one chip while maintaining the processing speed at video rate.

The Purchasing Trends of Purchase of Functional Progressive Addtions Lenses and Correlation Analysis of Binocular Function Value (기능성누진렌즈 구매고객의 구매동향 및 양안시기능값 상관성 분석)

  • Kim, Dong-min;Lee, Gi-yung;Park, Hyun-ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.255-261
    • /
    • 2015
  • Purpose: purchasing status and understanding trends of Functional progressive addtions lenses buyers', Correlation analysis of the Binocular Function value to determine ADD then can be apply sales and prescriptions. Methods: Years 2011 to 2014, 298 patients who were prescribed functional progressive lenses were analysed based on the prescription data and SPSS (Ver. 20.0) was treated using the statistics. Results: Results: The average age of our customers are $27.66{\pm}11.55$ years, average addition power is $+0.73{\pm}0.36D$, customers are using take a prescription of ADD $+0.75{\pm}0.28D$ was the highest 44.33% to 132 people. Near point of convergence of 276 people (92.62%) was mostly less than 10 cm, and near point of accommodation of 134 people (44.97%) was also below 10 cm, within 11~15 cm were 122 people (40.94%). Most of people were within normal range in terms of Near point of convergence and near point of accommodation, near point of accommodation tend to be longer than Near point of convergence. As you can see this result shows most of customers need extra help in their near point of accommodation instead of they are leak at it. FCC (Fused cross cylinder) check Value and ADD (addition power) tests showed that the value of a strong correlation (p=0.00), NPC and NPA were also p=0.001, the correlation of the NPC and ADD is p=0.003, In addition, NPA and ADD also showed a significant correlations (p=0.005). Near Point of Accommodation, negative relative accommodation, and positive relative accommodation are all significantly correlated (p=0.00). The short distance-related variables of the ADD which are NPC, NPA, Age, also appeared to side correlate significantly with each other. Conclusion: Binocular function values of the subjects were highly correlated with each other so precise examination is required. when Age young people are working at short distance, low ADD values was prescribed for solving discomfort. So, in the case of early presbyopia, accommodative insufficiency, or people feel fatigue when they often working at near although their accommodation function is normal, when functional progressive lenses are prescribed, expectation of this should be exactly notified.

Live-Action VR Re-lighting Pipeline Using Depth Information (깊이 정보를 활용한 실사 VR의 리라이팅 파이프라인)

  • Baek, Kwang-Ho;Lee, Junsang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.9
    • /
    • pp.1214-1219
    • /
    • 2018
  • A variety of VR contents are being introduced as of 2017. VR contents are concentrated in the genre of games and interactive because of the difficulty of $360^{\circ}$ shooting production environment. Live action $360^{\circ}$ VR content has many problems due to the difficulty of the production environment. In this paper, a three - dimensional information value is generated in binocular disparity of a real image by using a re-light technique based on real image data. The generated 3D information values are combined with a technique of converting the depth information into a depth map and a re-light technique by installing virtual lighting on the surface formed in the 3D space. In order to solve the problem of lighting exposure, we apply the technique of re-lighting to the VR production pipeline by comparing and analyzing the result image of actual image and virtual image data.

Design and Evaluation of Intelligent Helmet Display System (지능형 헬멧시현시스템 설계 및 시험평가)

  • Hwang, Sang-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.5
    • /
    • pp.417-428
    • /
    • 2017
  • In this paper, we describe the architectural design, unit component hardware design and core software design(Helmet Pose Tracking Software and Terrain Elevation Data Correction Software) of IHDS(Intelligent Helmet Display System), and describe the results of unit test and integration test. According to the trend of the latest helmet display system, the specifications which includes 3D map display, FLIR(Forward Looking Infra-Red) display, hybrid helmet pose tracking, visor reflection type of binocular optical system, NVC(Night Vision Camera) display, lightweight composite helmet shell were applied to the design. Especially, we proposed unique design concepts such as the automatic correction of altitude error of 3D map data, high precision image registration, multi-color lighting optical system, transmissive image emitting surface using diffraction optical element, tracking camera minimizing latency time of helmet pose estimation and air pockets for helmet fixation on head. After completing the prototype of all system components, unit tests and system integration tests were performed to verify the functions and performance.

A Study on Eye Point and Field of View of Older Drivers (고령운전자의 Eye Point와 전방 시계 특성에 관한 연구)

  • Lee, Seong-Il;Choi, Ji-Ho;Hwang, In-Jun;Song, Kyo-Hyun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • This study examined the field of view of older drivers based on their eye points. The subjects were 25 people whose age was over 65 years and 10 contrasting subjects on their 20s. For the experiment, we expanded the width of the A-pillar of a test vehicle. With a measuring apparatus designed for the study, we analyzed 3 axes of coordinates from glabella to a fixed point of the vehicle that would be used as CAD data of vehicle design. Result shows that average eye point of the older subjects was located significantly farther from the seat than that of the 20s approximately by 31.62mm(p=0.05). It was also found that the Binocular FOV was not significantly different between the older subjects and the 20s(p=0.85), and the effect of the width of the A-pillar on the FOV could not be found. We also measured the left and right side of the Ambinocular FOV of the older subjects. It was found that the older subjects had much wider visual angle than the 20s by 2.84 degree (F=4.78, p=0.01) on the left side, while the 20s showed significantly wider average angle than the older subjects by about 4.88 degree (F=4.78, p<0.05) on the right side. The results of this study can be used to improve the FOV based on the optimal eye points when designing a vehicle for older drivers.

Analysis of Refractive Error according to Aging in Young Children in South Korea (한국 어린이의 연령에 따른 굴절이상 분석)

  • Kim, Douk-Hoon;Kim, Dae-Nyoun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose. to describe the prevalence of refractive error according to aging in young children in South Korea. Methods : From July 2013 to June 2014, five hundred subjects( 250 male subjects, 250 female subjects; aged between 7 and 12 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+2.00$ D, cylinder error ${\geq}0.75$ D and SE difference${\geq}1.00$ D between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 80.41%, astigmatism 44.89%, emmetropia 18.27%, anisometropia 16.92%, and hyperopia 1.32%. The prevalence of myopia increased with age. but hyperopia was decrease. Myopia and astigmatism were much more common in male than females although the difference was not statically significant. Emmetropia and hyperopia were much more common in female than males although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to 0.99 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between 9 year and 10 year of female in the spherical equivalent power(p>0.05). In all another group of age, there was not a statistical significance as aging in spherical equivalent power(p>0.5). However, there was a statistical significance between male and female as age in the spherical equivalent power(P>0.01). Conclusions: Myopia was the most common refractive error in Korea young children, while hyperopia was decreased after 7 years. There was a statistical significance as age between male and female at spherical equivalent power(P> 0.01). these results suggested that the analysis of the refractive error as age at young children can give the useful diagnosis data for the correction of visual function.

Analysis of refraction status on the Presbyopia in Korea (한국인 노안 굴절상태 분석)

  • Kim, Douk-Hoon;Lee, Min-Ho
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.2
    • /
    • pp.1337-1344
    • /
    • 2019
  • Purpose. This study was the analyze the refractive status of presbyopia in Korea. Methods. The subjects was from November 2018 to October 2019, two hundred thirty four subjects( 117 male subjects, 117 female subjects; from 40-year old to 88-year old ) were performed in refraction test using the Auto-Refraction(Speed -K model, Japan). The myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)≤-0.50 diopters, SE ≥+1.00 D, cylinder error ≥0.75 D and SE difference≥1.00 D between binocular eyes, respectively. Results. The refractive status by spherical equivalent among all subjects was myopia 61.43%, astigmatism 86.86%, emmetropia 19.18%, anisometropia 12.07%, and hyperopia 18.54. The prevalence of myopia and astigmatism were much more common in male. However, The hyperopia and astigmatism were much more common in female. The prevalence of spherical equivalent was much common from -0.50 diopter to -5.00 diopter. On the other hand, the prevalence of astigmatism and myopia was much more than hyperopia in all subjects. There was a statistical significance between OD and OS of the female and male in the spherical equivalent power(p<.000). However, there was not statical significant between female and male of OD and OS in the spherical equivalent power(p<.070). On the other hand, The prevalence of againest axis in astigmatism was more common in all subjects. In ADD power for the near vision correction, the female was much more diopter than male. Conclusions. These results suggested that the analysis of the refractive status on the presbyopia in Korea can give the useful diagnosis data for the correction of visual acuity at near distance.

Measurements of Presbyopic Addition Using a Combination Chart of Cross-Grid and Red Green (십자와 적록 조합시표를 이용한 노안 가입도 측정)

  • Wee, Sung-Hyun;Moon, Byeong-Yeon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.115-119
    • /
    • 2008
  • Purpose: To compare the tentative and final addition, a combination chart of cross-grid and red green with the final addition prescribed in presbyopia were used in this study. Methods: The study subjects were 60 persons with presbyopia who were 41 to 60 years (mean: 51.7 years). Tentative addition were determined using red green chart (RG), cross-grid chart (CG) and the combination chart (red green cross-grid chart, RGCG) of the above two. And the final addition for a 40 cm working distance was determined for each subject by adjusting the tentative addition. Results: It was found that there were statistically significant differences of the final addition and the tentative addition between the each different test method. This result indicated that using the red-green cross-grid chart is the higher repeatability. Conclusions: This study shows that red green cross-grid chart (RGCG) seems to be get proper data for determining addition in presbyopes, and this method would be helpful in the diagnostic evaluation of addition in binocular vision testing.

  • PDF

Study on Compositing Editing of 360˚ VR Actual Video and 3D Computer Graphic Video (360˚ VR 실사 영상과 3D Computer Graphic 영상 합성 편집에 관한 연구)

  • Lee, Lang-Goo;Chung, Jean-Hun
    • Journal of Digital Convergence
    • /
    • v.17 no.4
    • /
    • pp.255-260
    • /
    • 2019
  • This study is about an efficient synthesis of $360^{\circ}$ video and 3D graphics. First, the video image filmed by a binocular integral type $360^{\circ}$ camera was stitched, and location values of the camera and objects were extracted. And the data of extracted location values were moved to the 3D program to create 3D objects, and the methods for natural compositing was researched. As a result, as the method for natural compositing of $360^{\circ}$ video image and 3D graphics, rendering factors and rendering method were derived. First, as for rendering factors, there were 3D objects' location and quality of material, lighting and shadow. Second, as for rendering method, actual video based rendering method's necessity was found. Providing the method for natural compositing of $360^{\circ}$ video image and 3D graphics through this study process and results is expected to be helpful for research and production of $360^{\circ}$ video image and VR video contents.

A Study on the Application of Stereoscopic Depth Value in VR HMD (VR HMD 기반의 스테레오스코픽 깊이 값 적용 연구)

  • Son, Ho-Jun;Kim, Jung-Ho;Lee, Seung-Hyun;Hamacher, Alaric;Kwon, Soon-Chul
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.4
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, technology of Virtual Reality(VR) based on HMD among various kinds of VR implemented products has received widespread attention. Major IT-related companies around the world participated in VR HMD research and development. Therefore, the possibility of the spread of VR HMD has been highly praised. Demands of VR HMD products using Smart Phone has been especially increased so that it is required to create a high quality of VR contents. The purpose of study in this paper is to apply the depth value of stereoscopic to VR HMD. To implement it, we analyzed VR HMD optical system and converted an experimental image to virtual depth caused by binocular disparity based on the result of calculating NPP(Native Pixel Parallax). We produced the image of stereoscopic applied with the value converted and applied to VR HMD. This study is expected to be utilized as a VR content creation field of quantitative data.