• Title/Summary/Keyword: attached facilities

Search Result 146, Processing Time 0.027 seconds

A Study on the Diagnostic Technology for Fouling Occurred in Heat Exchanger (열교환설비에서의 파울링 진단기술에 관한 연구)

  • Chung Kyung-Yul;Rhyu Keel-Soo;Lee Hoo-Rach
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.502-508
    • /
    • 2005
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried. e.g., diagnosis of fouling, reducing and eliminating the fouling. etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously. The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall. The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator. In addition to, we showed the data that have been executed in field test for reliability verification.

Users' Behavior Study for the Planning of One-room System Houses (원룸시스템 주택 계획을 위한 거주자 행태연구)

  • 조성희;권미지
    • Journal of the Korean housing association
    • /
    • v.14 no.3
    • /
    • pp.165-174
    • /
    • 2003
  • The demand for one-room system house as a new type of house will increase gradually, and residents also tend to be diversified. However, a method of planning of planning of one-room system house was limited and unified. Current floor plans of the one-room don't utilize a benefit of open plan in small areas. The purpose of this study is to propose several guidelines for the planning of one-room system houses that correspond to residents' needs in order to facilitate the benefit of open plan such as efficiency and multi-purpose use in small area. For this, a field survey was carried out as case studies, with individual interviews, questionnaires, and actual survey including taking pictures. Subjects were 50 residents who living in one-room system houses in Busan. Space usage behavior of residents, residential satisfactions, and preference attitudes on the attached service facilities were analyzed. The results were synthesized to suggest several guidelines for planning of one-room system house.

A Study on The Diagnostic Technology for Fouling Occurred in Heat Exchanger. (열 교환설비에서의 파울링 진단기술에 관한 연구)

  • 정경열;이후락;박정일;김상렬;류길수
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.181-186
    • /
    • 2002
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried, e.g., diagnosis of fouling, reducing and eliminating the fouling, etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator.

  • PDF

Requirement Analysis and Conceptual Design for a Cybrid Virtual Plant System (Cybrid 가상플랜트 시스템 요구사항 분석과 개념적 설계)

  • Lee, Jae Hyun;Suh, Hyo Won
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.401-411
    • /
    • 2015
  • Cybrid virtual plant concept is defined as a cyber plant mimicking a physical plant by using plant engineering data and sensor data coming from sensors attached to facilities of the physical plant. Cybrid virtual plant is a new concept for plant industry so that plant managers and operators' requirements need to be captured for systematic application of the concept to the plant industry. The paper proposed an architecture of the cybrid virtual plant, and provided requirement analysis results for a specific plant company. A database, named smart-cube repository, for the proposed cybrid virtual plant is also proposed and its conceptual data structure is described.

Sole and Combined Usage of Ultra-sonication and Hydrogen Peroxide as Mitigation Techniques of Bio-fouling

  • Haque, Md. Niamul;Kwon, Sung-hyun
    • Journal of Environmental Science International
    • /
    • v.25 no.10
    • /
    • pp.1397-1405
    • /
    • 2016
  • Mussels are stubborn organism attached to solid substrate by byssus threads and caused operational problems in utility of power generating stations. Sole and combined usage of ultrasonic (28 kHz- and 42 kHz- frequencies) and hydrogen peroxide ($H_2O_2$) has studied for control of blue mussel larvae and adult stage in seawater condition. A theoretical wo rking model using disinfection (Chick and Watson type) approaches is presented based on helpful results of experiments. This study also demonstrate that the combined treatment (ultra-sonication with $H_2O_2$) is overall highly efficient than individual treatment would, but on the basis of exposure time, the ultra-sonication was the most efficient among them. Therefore the development of sole and combined technique might be effective practical mitigation strategy against mussel attachment for water handling facilities.

Efficient allocation scheme for Grid Sensor Network detecting movement of targeted objects (이동체 위치 인식을 위한 그리드 센서 네트워크의 효율적인 적용 방안 연구)

  • Seo, Ki-Won;Kim, Jong-Cheol;Roh, Hyoung-Hwan;Oh, Ha-Ryoung;Seong, Yeong-Rak;Park, Jun-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.473-477
    • /
    • 2008
  • In this paper, we introduce the positioning methods using the grid sensor network. The basic operational principle of grid sensor network can be the wireless communication using the sensor node attached on the objects. Sink node receives the environmental information (e.g., temperature, humidity and so on), and transmits the information to the core database. Since the grid sensor network basically uses wireless communication, it is necessary to observe the place where grid sensor nodes to be installed. In this sense, we carried out the practical measurement on the wireless propagation in an applicable field. In addition, link budget study and SNR estimation works were done in accordance with the results from the measurement.

  • PDF

Environmental Color Design for the Factory of the H. Company (H사 공장의 환경 색채 디자인)

  • Kim, Jung-Keun;Ju, Jung-Hee
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.233-234
    • /
    • 2005
  • The design in this study is making a plan for the exterior color design for the factory of the H. company. The concept of this design is an integrated color program considering the physical characteristics of the buildings and the functional features of the factories. And this program is based on the aesthetic characteristics forming the men-friendly, professional environment and the environment-friendly, factory image. The scope of this design was limited to the exterior color for 1 office building and 3 factory buildings, including 7 attached facilities. All the 6 colors were selected, and the blue, the company logo color, is the main color.

  • PDF

Jeonnam Medical College's Interior Design - Harmony in Space - (전남의대 업무공간을 위한 실내디자인 - 공간 조화 -)

  • Choi, Sun-Hee
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.235-236
    • /
    • 2005
  • A medical college is faculty which performs frequent experiments and holds lots of seminars for these reasons, this place was designed to exchange its concentration, taking its spatial psychology convenience and its functions into consideration. This space has been built up as the technological and multi-functional space to encourage it to accomplish special functions required by each of facilities, such as the president room, a main center of administration in the medical college, an audience chamber, an attached room, the room for alumni, preventive medicine and Micro biological diseases, a legal medicine lecture room, the room for basic medical science and a conference room.

  • PDF

Classification of Operating State of Screw Decanter using Video-Based Optical Flow and LSTM Classifier

  • Lee, Sang-Hyeop;Wesonga, Sheilla;Park, Jang-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.2_1
    • /
    • pp.169-176
    • /
    • 2022
  • Prognostics and health management (PHM) is recently converging throughout the industry, one of the trending issue is to detect abnormal conditions at decanter centrifuge during water treatment facilities. Wastewater treatment operation produces corrosive gas which results failures on attached sensors. This scenario causes frequent sensor replacement and requires highly qualified manager's visual inspection while replacing important parts such as bearings and screws. In this paper, we propose anomaly detection by measuring the vibration of the decanter centrifuge based on the video camera images. Measuring the vibration of the screw decanter by applying the optical flow technique, the amount of movement change of the corresponding pixel is measured and fed into the LST M model. As a result, it is possible to detect the normal/warning/dangerous state based on LSTM classification. In the future work, we aim to gather more abnormal data in order to increase the further accuracy so that it can be utilized in the field of industry.

Comparison of Laser Scabbling Efficiency According to Concrete Mixing Design Conditions (콘크리트 배합설계조건에 따른 레이저 스캐블링 효율성 비교)

  • Heo, Seong-Uk;Lee, Jae-Yong;Chung, Chul-Woo;Kim, Ji-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.156-157
    • /
    • 2021
  • Since concrete is contaminated or radioactive during operation of nuclear power plants, it is the most important radioactive waste generated during the dismantling of a nuclear power plant. The amount of waste is different depending on the pollution state of each facility and the applied technology is different, so there is a big difference. We aim to reduce the amount of waste and increase the value of recyclability through technology to remove radionuclides attached to the surface. For this purpose, laser scabbling, which exfoliates the surface of concrete by irradiating a laser, and a facility system for controlling dust and dust are used in parallel. The purpose of this study is to evaluate the efficiency of laser scabbling by manufacturing simulated concrete for nuclear facilities, and to review the optimal mixing design conditions for nuclear facility structures.

  • PDF