Browse > Article
http://dx.doi.org/10.5322/JESI.2016.25.10.1397

Sole and Combined Usage of Ultra-sonication and Hydrogen Peroxide as Mitigation Techniques of Bio-fouling  

Haque, Md. Niamul (Department of Ocean System Engineering, College of Marine Science, Gyeongsang National University)
Kwon, Sung-hyun (Department of Marine Environmental Engineering, College of Marine Science, Engineering Research Institute (ERI), Gyeongsang National University)
Publication Information
Journal of Environmental Science International / v.25, no.10, 2016 , pp. 1397-1405 More about this Journal
Abstract
Mussels are stubborn organism attached to solid substrate by byssus threads and caused operational problems in utility of power generating stations. Sole and combined usage of ultrasonic (28 kHz- and 42 kHz- frequencies) and hydrogen peroxide ($H_2O_2$) has studied for control of blue mussel larvae and adult stage in seawater condition. A theoretical wo rking model using disinfection (Chick and Watson type) approaches is presented based on helpful results of experiments. This study also demonstrate that the combined treatment (ultra-sonication with $H_2O_2$) is overall highly efficient than individual treatment would, but on the basis of exposure time, the ultra-sonication was the most efficient among them. Therefore the development of sole and combined technique might be effective practical mitigation strategy against mussel attachment for water handling facilities.
Keywords
Biofouling; Ultra-sonication; Hydrogen peroxide; Mytilus edulis; Cavitation; Mussel;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bott, T. R., Tianqing, L., 2004, Ultrasound enhancement of biocide efficiency, Ultrasonic Sono-Chemistry, 11, 323-326.   DOI
2 Bougrier, C., Carrere, H., Delgenes, J. P., 2005, Solubilisation of waste activated sludge by ultrasonic treatment, Chemical Engineering Journal, 106, 163-169.   DOI
3 Cavaletto, M., Ghezzi, A., Burlando, B., Evangelisti, V., Ceratto, N., Viarengo, A, 2002, Effect of hydrogen peroxide on antioxidant enzymes and metallo thionein level in the digestive gland of Mytilus galloprovincialis, Comparative Biochemistry and Physiology Part C, 131, 447-455.
4 Chand, R., Bremner, D. H., Namkung, K. C., Collier, P. J., Gogate, P. R., 2007, Water disinfection using the novel approach of ozone and a liquid whistle reactor, Biochemical Engineering Journal, 35, 357-364.   DOI
5 Chick, H., 1908, An investigation into the law of disinfection, Journal of Hygiene (Cambridge), 8, 92-158.   DOI
6 Daniel, R., Jos, F. C., Enrique, N., 2015, Assessment of the antifouling effect of five different treatment strategies on a seawater cooling system, Applied Thermal Engineering, 85, 124-134.   DOI
7 Dehghani, M. H., 2005, Effectiveness of ultrasound on the destruction of E. Coli, American Journal of Environmental Science, 1, 187-189.   DOI
8 Donskoy, D. M., Ludyanski, M. L., 1995, Low frequency sound as a control measure for zebra mussels fouling, Proceeding of the Fifth International Zebra Mussels and Other Aquatic Nuisance Organism Conference, 14-21 February 1995, Torento, Canada, 103-112.
9 Gopal, K., Tripathy, S. S., Bersillon, J. L., Dubey, S. P., 2007, Chlorination byproducts, their toxicodynamics and removal from drinking water, Journal of Hazardous Materials, 140, 1-6.   DOI
10 Harrington, D. K., Van Benschoten, J. E., Jensen, J. N., Lewis, D. P., Neuhauser, E. F., 1997, Combined use of heat and oxidants for controlling adult zebra mussels, Water Research, 31, 2783-2791.   DOI
11 Martin, L. D., Mackie, G. L., Baker, M. A., 1993, Acute toxicity tests and pulsed-dose delayed mortality at 12 and $22^{\circ}C$ in the zebra mussel (Dreissena polymorpha), Arch. Environ. Contam. Toxicol., 24, 389-398.   DOI
12 Jenner, H. A., Whitehouse, J. W., Taylor, C. J. L., Khalanski, M., 1998, Cooling water management in European power stations: Biology and Control, Hydro Ecologie Appliquee, 1-225.
13 Kleiser, G., Frimmel, F. H., 2000, Removal of precursors for disinfection by-products (DBPs) Differences between ozone- and OH-radical induced oxidation, Science of the Total Environment, 256, 1-9.   DOI
14 Klerks, P. L., Fraleigh, P. C., Stevenson, R. C., 1993, Controlling zebra mussel (Dreissena polymorpha) veligers with three oxidizing chemicals: Chlorine, permanganate and peroxide iron, In: Nalepa, Schloesser, T. F., and D. W., (Eds.), Zebra Mussels: Biology, Impacts and Control, 1993, 621-641, Florida.
15 Mason, T. J., Peters, D., 2002, Practical Sono-Chemistry: Power Ultrasound and Applications, Second Edition, Horwood, Chichester, England.
16 Moubad, A., Fdil, M. A., Maarouf, A., Pihan, J. C., 2001, Pumping behavior and filtration rate of the fresh water mussel Potamidalittoralis as a tool for rapid detection of water contamination, Aquatic Ecology, 35, 51-60.   DOI
17 Nalepa, T. F., Schloesser, D. W., 1993, Zebra Mussels: Biology, Impacts, and Control, Boca Raton, FL: Lewis Publishers, 623-633.
18 Neppiras, E. A., 1980, Acoustic Cavitation, Physical Report, 61, 159-251.   DOI
19 Pedahzur, R., Lev, O., Fattal, B., Shuval, H. I., 1995, The interaction of silver ions and hydrogen peroxide in the inactivation of E.coli: A preliminary of a new long acting residual drinking water disinfectant, Water Science and Technology, 31, 123-129.
20 Philli, S., Bhunia, P., Yan, S., LeBlanc, R. J., Tyagi, R. D., Surampalli, R. Y., 2011, Ultrasonic treatment of sludge: A review, Ultrasonic Sono-Chemistry, 18, 1-18.   DOI
21 Rajagopal, S., Van der Velde, G., Van der Gaag, M., Jenner, H. A., 2003, How efficient is intermittent chlorination to control adult mussel fouling in cooling water systems?, Water Research, 37(2), 329-338.   DOI
22 Sadiq, R., Rodrssiguez, M. J., 2004, Disinfection byproducts (DBPs) in drinking water and predictive models for their occurrence: A review, Science of the Total Environment, 321, 21-46.   DOI
23 Veila, J. A., Pudera, M. G., Littletonb, D. J., Mosesc, D. O., 1999, Cooling water use patterns at US nonutility electric generating facilities, Environmental Science and Policy, 2, 477-487.   DOI
24 Wait, I. W., Johnston, C. T., Blatchley, E. R., 2007, The influence of oxidation reduction potential and water treatment processes on quartz lamp sleeve fouling in ultraviolet disinfection reactors, Water Research, 41, 2427-2436.   DOI
25 Watson, H. E., 1908, A note on the variation of the rate of disinfection with change in the concentration of the disinfectants, Journal of Hygiene (British), 8(4), 536-542.   DOI
26 Winward, G. P., Avery, L. M., Stephenson, T., Jefferson, B., 2008, Chlorine disinfection of grey water for reuse: Effect of organics and particles, Water Research, 42, 483-491.   DOI
27 Yang, L., Chang, W. S., Lo Huang, M. N., 2000, Natural disinfection of water in marine outfall fields, Water Research, 34, 743-750.   DOI