• 제목/요약/키워드: apparatus

검색결과 4,308건 처리시간 0.03초

충격전류발생장치의 실험적연구 (Experimental Study of Impulsive High Current Generating Apparatus)

  • 김안균
    • 전기의세계
    • /
    • 제24권4호
    • /
    • pp.73-76
    • /
    • 1975
  • In this study, a design scheme of an impulsive high current generating device is presented. The device is proved to be effective in producing rather complex type of the permanent magnet. Principally, the apparatus designed same to the ordinary potential transformer or current transformer, but, it has a certain differences that the primary winding of many turns is excited by d.c. source and the secondary winding of a few turns induce low voltage and high current at the instant when opening a switch in the primary circuit. This paper does not include magnet production process. Rather, it deals with the analytical studies of the devices, the designing procedure of the experimental setup, and some results from the experimental data are presented as a preliminary study. The experimental results are found to agree well with the theoritical analysis presented in this paper.

  • PDF

부피법 자동장치를 이용한 LaNi5 수소화합물의 열분석 장치개발 (Thermal Analysis of LaNi5 Hydride by Volumetric Method)

  • 한정섭;김선중
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.25-31
    • /
    • 2018
  • To apply Sievert's type apparatus to thermal analysis of hydrogen absorption materials, the dehydrogenation of $LaNi_5$ system was investigated. As the initial wt% of hydrogen was increased from 0.44 to 1.24 wt%, the peak temperature of evolution rate shifted to higher temperature. However, with the initial wt% of hydrogen higher than 0.95 wt%, the peak temperature of evolution rate did not change. As the heating rate was increased, the peak temperature increased; the peak temperatures for heating rates 0.5, 1.0 and 1.5 K/min were 262.2, 264.1, and 265.9 K respectively. The Sievert's type automatic apparatus can be successively applied to the thermal analysis of $LaNi_5$ hydride.

저 비트율 전력선 모뎀에 대한 저압 댁내망의 채널 특성 시뮬레이션 기법에 관한 연구 (A Simulation Technique for the Characterization of the Low-bit-rate Household AC Power Line Communication Channel)

  • 안남호;정태규
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권5호
    • /
    • pp.197-202
    • /
    • 2002
  • In this paper, the characteristics of the household AC power line network is analyzed for the low bit rate powerline communication (PLC) in the frequency range from 10㎑ to 450㎑ The PLC channel transfer characteristics including its characteristic impedance are derived based on the network topology which is constructed with the household power lines loaded with the various types of electric apparatus. Both the distributed circuit analysis and the lumped circuit model based analysis are applied for the characterization of the PLC channel and the results are compared by the computer simulations. The analysis illustrates very well the adverse effects caused by the loading of electric apparatus and as well those casued by the reflection of wavers in the household AC Power line communication network.

대전력시험에서 고전압 측정시스템의 불확도 평가 (The estimation of uncertainty in high-voltage measuring system used in high-power tests)

  • 서윤택;김맹현;김대원;정주영;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.348-350
    • /
    • 2002
  • In the high-power tests to be performed on electrical apparatus as switchgears, transformers, insulators, cable and so on the results of tests on these apparatus are extremely important to evaluate the performance of test object. The reliability of the results depends on the reliability of measuring systems used in the laboratories where tests are performed. This paper introduces factors of uncertainty and describes estimation of uncertainty in high-voltage measuring system used in high-power testing LAB. 1 in KERI.

  • PDF

초전도기기 전류레벨협조와 절연협조를 고려한 초전도전력시스템구성을 위한 기초연구 (A Configuration of Superconducting Power System Considering the Current Level & Electric Insulation Coordination of Superconducting Apparatus)

  • 홍원표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1208-1210
    • /
    • 1999
  • Design & operation power systems for meeting increase of electric power demand is becoming more difficult and complex. Some of limitations of conventional technology can be broken through by the application of superconductivity technology. This paper presents a new concept & image for the configuration of superconducting power system which has introduced superconducting(SC) generator, cable, transformer, fault current limiter(SFCL), SMES, etc. Engineering evaluation of each power apparatus and its assessment of application to power system were conducted. Futhermore, it is pointed that superconducting power system require a new operating condition. This is, SFCL should play a important part of quenching current level coordination to prevent the other superconducting devices from quenching. Its designing & operating condition including SFCL was discussed in viewpoint of quenching current level and insulation coordination of SC coil.

  • PDF

전력 Switching 소자를 압전트랜스로 구동하는 방법 (The Driving Method of Power Switching Device Using Pizoelectric Transformer)

  • 황민규;이상균;이재춘;최준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1324-1326
    • /
    • 1998
  • To drive motor or heating machine, it needs the electric power system like the apparatus of inverter. This electric power system obviously comprises power switching devices and drivers to run them. And this system has the topology comprised one/many arm(s), - each arm has high side switching device and low side switching device. Transformer, photocoupler, and HVIC having functions of isolation and level shift which are important thing to drive high side switching device are used as component of drivers in conventional apparatus. Piezoelectric transformers are proposed in this paper, and applied to drive high side swiching device. Through experiments, the possiblities of driving high side switching device are presented and the problems are mooted concurrently. But, we also consider a counterplan for solving the mooted trouble issues.

  • PDF

2D 햅틱 인터페이스 장치 설계 및 이를 이용한 가상 에어하키 시스템 구현 (Design and fabrication of a 2D haptic interface apparatus and the realization of a virtual air-hockey system using the device)

  • 백종원;강지민;용호중;최대성;장태정
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.78-80
    • /
    • 2005
  • Haptic interface apparatus is the device which can offer users virtual reality not only by visualization of virtual space but also by force or tactile feedback. In this paper, we designed and fabricated a 2D haptic interface device that can be used for various purposes, and implemented a virtual air-hockey system that users can easily find in game rooms. By suitable modeling and haptic rendering, users can feel the impact and the reaction force with his/her hand holding the handle through 2D haptic interface device when he/she hit an air-hockey puck with the handle. Through the trial demonstration. we observed the reasonable effect of direction and speed of a ball like doing in reality.

  • PDF

초음파를 이용한 슬러지 탄소원 (Sludge Carbon Source Using Ultrasonic apparatus)

  • 김영규;임영택
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.29-30
    • /
    • 2002
  • In this study, comparison the removal efficiencies of organics, nitrogens and phosphorus from sewage using Ultrasonic apparatus were investigated. The concentration of SCODcr were respectively 16.3, 24.4, 48.8, 105.7, 260.3 mg/$\ell$ with time 0, 10, 30, 60, 120min respectively in 200W ultrasonic intensity. The concentration of SCODcr were respectively 124.4, 48.8, 73.2, 203.4, 374.2 mg/$\ell$ with time 0, 10, 30, 60, 120min respectively in 300W ultrasonic intensity. The concentration of SCODcr were respectively 24.4, 40.7, 81.4, 170.9, 439.3 mg/$\ell$ with time 0, 10, 30, 60, 120min respectively in 400W ultrasonic intensity.

  • PDF

평판형 ER-Valve의 제작 및 성능실험 (Design and Performance Test of Plate Type ER-Valve)

  • 장성철;염만오
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

생체(生體) 기(氣)의 파동(波動) 공명적(共鳴的)인 연구(硏究) 현황(現況) (The study on the wave-resonance for the bio-KI)

  • 김경철;홍미숙
    • 대한예방한의학회지
    • /
    • 제4권1호
    • /
    • pp.152-162
    • /
    • 2000
  • The present condition of study on the wave-resonance for the bio-KI is observed. The results are as follows: 1. Tn the wave-resonant stand point, the tendency of studying on KI is showed in the several field all over the world. 2. Because it is originated radionics, the wave-resonant tools of MRA insistenting minute-magnetism-resonance-apparatus need the more severe data in the side of electric circuit. 3. The wave resonance apparatus according to the frequency occurance transmits low-frequency's vibration ratio to the electric stimulating aspect. 4. The wave-water is considered on the application of wave-resonance transcription on the water, and needs the comprehension of torsion-field level.

  • PDF